Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.

Pulse Pressure and Risk of New-Onset Atrial Fibrillation

Mitchell, Gary F., Vasan, Ramachandran S., Keyes, Michelle J., Parise, Helen, Wang, Thomas J., Larson, Martin G., D’Agostino, Ralph B., Kannel, William B., Levy, Daniel, Benjamin, Emelia J.·2007·JAMA

Abstract

CONTEXT: Atrial fibrillation (AF) is responsible for considerable morbidity and mortality, making identification of modifiable risk factors a priority. Increased pulse pressure, a reflection of aortic stiffness, increases cardiac load and may increase AF risk. OBJECTIVE: To examine relations between pulse pressure and incident AF. DESIGN, SETTING, AND PARTICIPANTS: Prospective, community-based observational cohort in Framingham, Mass, including 5331 Framingham Heart Study participants aged 35 years and older and initially free from AF (median age, 57 years; 55% women). MAIN OUTCOME MEASURES: Incident AF. RESULTS: AF developed in 698 participants (13.1%) a median of 12 years after pulse pressure assessment. Cumulative 20-year AF incidence rates were 5.6% for pulse pressure of 40 mm Hg or less (25th percentile) and 23.3% for pulse pressure greater than 61 mm Hg (75th percentile). In models adjusted for age, sex, baseline and time-dependent change in mean arterial pressure, and clinical risk factors for AF (body mass index, smoking, valvular disease, diabetes, electrocardiographic left ventricular hypertrophy, hypertension treatment, and prevalent myocardial infarction or heart failure), pulse pressure was associated with increased risk for AF (adjusted hazard ratio [HR], 1.26 per 20-mm Hg increment; 95% confidence interval [CI], 1.12-1.43; P<.001). In contrast, mean arterial pressure was unrelated to incident AF (adjusted HR, 0.96 per 10-mm Hg increment; 95% CI, 0.88-1.05; P = .39). Systolic pressure was related to AF (HR, 1.14 per 20-mm Hg increment; 95% CI, 1.04-1.25; P = .006); however, if diastolic pressure was added, model fit improved and the diastolic relation was inverse (adjusted HR, 0.87 per 10-mm Hg increment; 95% CI, 0.78-0.96; P = .01), consistent with a pulse pressure effect. Among patients with interpretable echocardiographic images, the association between pulse pressure and AF persisted in models that adjusted for baseline left atrial dimension, left ventricular mass, and left ventricular fractional shortening (adjusted HR, 1.23; 95% CI, 1.09-1.39; P = .001). CONCLUSION: Pulse pressure is an important risk factor for incident AF in a community-based sample. Further research is needed to determine whether interventions that reduce pulse pressure will limit the growing incidence of AF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jama.297.7.709

Cites

40 of 40 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 40 references

Cited by

See all 362

Metadata

Authors
Mitchell, G. F., Vasan, R. S., Keyes, M. J., Parise, H., Wang, T. J., Larson, M. G., D’Agostino, R. B., Kannel, W. B., Levy, D., & Benjamin, E. J.
Venue
JAMA
Published
2007-02-21
Volume
297
Issue
7
Pages
709
ISSN
  • 0002-9955 (ISSN-L)
  • 0098-7484
OpenAlex
W2146518212
Cited by
362
References
40
FWCI
14.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulse Pressure and Risk of New-Onset Atrial Fibrillation. https://app.cochat.ai/papers/10.1001/jama.297.7.709
The paper
Mitchell, G. F., Vasan, R. S., Keyes, M. J., Parise, H., Wang, T. J., Larson, M. G., D’Agostino, R. B., Kannel, W. B., Levy, D., & Benjamin, E. J. (2007). Pulse Pressure and Risk of New-Onset Atrial Fibrillation. JAMA. https://doi.org/10.1001/jama.297.7.709

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.