Association of Survival With Femoropopliteal Artery Revascularization With Drug-Coated Devices
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Importance: In a recent meta-analysis of randomized clinical trials, femoropopliteal artery revascularization with paclitaxel drug-coated devices was associated with increased long-term all-cause mortality compared with non-drug-coated devices. However, to our knowledge, these findings have not been replicated in other data sources and may be subject to confounding from missing data associated with patient withdrawal and loss to follow-up. Objective: To evaluate differences in all-cause mortality between patients who were treated with drug-coated devices vs non-drug-coated devices for femoropopliteal artery revascularization. Design, Setting, and Participants: This nationwide, multicenter retrospective cohort study included 16 560 Centers for Medicare and Medicaid Services beneficiaries who were admitted for femoropopliteal artery revascularization from January 1, 2016, to December 31, 2016. All-cause mortality was analyzed through September 30, 2017. Exposures: Drug-coated devices (drug-eluting stent [DES] or drug-coated balloon [DCB]) compared with non-drug-coated devices (bare metal stent or uncoated percutaneous transluminal angioplasty balloon). Main Outcomes and Measures: The primary outcome was all-cause mortality analyzed through the end of follow-up. Results: Among 16 560 patients treated at 1883 hospitals, the mean (SD) age was 72.9 (11) years, 7734 (46.7%) were men, 12 232 (73.9%) were white, 8222 (49.7%) currently or had previously used tobacco, 9817 (59.3%) had diabetes, and 8450 (51.0%) had critical limb ischemia (CLI). Drug-coated devices were used in 5989 participants (36.2%). The median follow-up was 389 days (interquartile range, 277-508 days). Among all patients, treatment with drug-coated devices was associated with a lower cumulative incidence of all-cause mortality compared with treatment with non-drug-coated devices through 600 days postprocedure (32.5% vs 34.3%, respectively; log-rank P = .007). Similar survival trends were observed when treatment was stratified by using a DCB alone or DES with or without DCB. After multivariable adjustment, drug-coated devices were not associated with a difference in all-cause mortality compared with non-drug-coated devices (hazard ratio [HR], 0.97; 95% CI, 0.91-1.04; P = .43). These findings were consistent among those with CLI (HR, 0.93; 95% CI, 0.85-1.01; P = .09) or without CLI (HR, 0.94; 95% CI, 0.85-1.03; P = .20), and for those treated with DCB alone (HR, 0.94; 95% CI, 0.86-1.03; P = .17) or DES with or without DCB (HR, 0.97; 95% CI, 0.89-1.06; P = .48). Conclusions and Relevance: In this large nationwide analysis of Centers for Medicare and Medicaid Services beneficiaries, there was no evidence of increased all-cause mortality following femoropopliteal artery revascularization with drug-coated devices compared with non-drug-coated devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Meta-analysis of individual participant data: rationale, conduct, and reporting
Riley, R. D., Lambert, P. C., & Abo-Zaid, G. (2010) · BMJ · doi:10.1136/bmj.c221 · Cited by 1,701
Cited by
Mortality with Paclitaxel-Coated Devices in Peripheral Artery Disease
Nordanstig, J., James, S., Andersson, M., Andersson, M., Danielsson, P., Gillgren, P., Delle, M., Engström, J., Fransson, T., Hamoud, M., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2005206 · Cited by 215
Mortality after use of paclitaxel-based devices in peripheral arteries: a real-world safety analysis
Freisinger, E., Koeppe, J., Gerss, J., Goerlich, D., Malyar, N. M., Marschall, U., Faldum, A., & Reinecke, H. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz698 · Cited by 192
Mortality and Paclitaxel-Coated Devices: An Individual Patient Data Meta-Analysis
Rocha-Singh, K. J., Duval, S., Jaff, M. R., Schneider, P. A., Ansel, G. M., Lyden, S. P., Mullin, C. M., Ioannidis, J. P. A., Misra, S., Tzafriri, A. R., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.044697 · Cited by 164
Self-citation
Metadata
- Authors
- Secemsky, E. A., Kundi, H., Weinberg, I., Jaff, M. R., Krawisz, A., Parikh, S. A., Beckman, J. A., Mustapha, J., Rosenfield, K., & Yeh, R. W.
- Venue
- JAMA Cardiology
- Publisher
- American Medical Association (AMA)
- Published
- 2019-04-01
- Volume
- 4
- Issue
- 4
- Pages
- 332
- ISSN
- 2380-6583 (ISSN-L)
- OpenAlex
- W2913667111
- Cited by
- 211
- References
- 1
- FWCI
- 34.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.