Arm Position and Blood Pressure Readings: The ARMS Crossover Randomized Clinical Trial
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Importance: Guidelines for blood pressure (BP) measurement recommend arm support on a desk with the midcuff positioned at heart level. Still, nonstandard positions are used in clinical practice (eg, with arm resting on the lap or unsupported on the side). Objective: To determine the effect of different arm positions on BP readings. Design, Setting, and Participants: This crossover randomized clinical trial recruited adults between the ages of 18 and 80 years in Baltimore, Maryland, from August 9, 2022, to June 1, 2023. Intervention: Participants were randomly assigned to sets of triplicate BP measurements with the arm positioned in 3 ways: (1) supported on a desk (desk 1; reference), (2) hand supported on lap (lap), and (3) arm unsupported at the side (side). To account for intrinsic BP variability, all participants underwent a fourth set of BP measurements with the arm supported on a desk (desk 2). Main Outcomes and Measures: The primary outcomes were the difference in differences in mean systolic BP (SBP) and diastolic BP (DBP) between the reference BP (desk 1) and the 2 arm support positions (lap and side): (lap or side − desk 1) − (desk 2 − desk 1). Results were also stratified by hypertensive status, age, obesity status, and access to health care within the past year. Results: The trial enrolled 133 participants (mean [SD] age, 57 [17] years; 70 [53%] female); 48 participants (36%) had SBP of 130 mm Hg or higher, and 55 participants (41%) had a body mass index (calculated as weight in kilograms divided by height in meters squared) of 30 or higher. Lap and side positions resulted in statistically significant higher BP readings than desk positions, with the difference in differences as follows: lap, SBP Δ 3.9 (95% CI, 2.5-5.2) mm Hg and DBP Δ 4.0 (95% CI, 3.1-5.0) mm Hg; and side, SBP Δ 6.5 (95% CI, 5.1-7.9) mm Hg and DBP Δ 4.4 (95% CI, 3.4-5.4) mm Hg. The patterns were generally consistent across subgroups. Conclusion and Relevance: This crossover randomized clinical trial showed that commonly used arm positions (lap or side) resulted in substantial overestimation of BP readings and may lead to misdiagnosis and overestimation of hypertension. Trial Registration: ClinicalTrials.gov Identifier: NCT05372328
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Even when a validated automated device is used, the accuracy of BP measurement may be influenced by many factors. 19 – 21”
From Hypertension Canada guideline for the diagnosis and treatment of hypertension in adults in primary care (2025) · cites this paper as [21]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000065 · Cited by 7,391
Whelton, P. K., Carey, R. M., Aronow, W. S., Casey, D. E., Collins, K. J., Dennison Himmelfarb, C., DePalma, S. M., Gidding, S., Jamerson, K. A., Jones, D. W., et al. (2018) · Hypertension · doi:10.1161/hyp.0000000000000066 · Cited by 4,347
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Kallioinen, N., Hill, A., Horswill, M. S., Ward, H. E., & Watson, M. O. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001197 · Cited by 357
Epidemiological Perspective of Body Position and Arm Level in Blood Pressure Measurement
Terént, A., & Breig-åsberg, E. (1994) · Blood Pressure · doi:10.3109/08037059409102246 · Cited by 70
Research works printed but not linked: 18
- Beevers, 2001, Blood pressure measurement: part I—sphygmomanometry: factors common to all techniques., BMJ, 322, 981, 10.1136/bmj.322.7292.981 · DOI · Paper page
- Merendino, 1961, Importance of the position of the arm on the level of arterial blood pressure., JAMA, 175, 51, 10.1001/jama.1961.63040010010015c · DOI
- Familoni, 2005, Comparison of the effects of arm position and support on blood pressure in hypertensive and normotensive subjects., Cardiovasc J S Afr, 16, 85
- Silverberg, 1977, The unsupported arm: a cause of falsely raised blood pressure readings., BMJ, 2, 1331, 10.1136/bmj.2.6098.1331 · DOI · Paper page
- Beck, 1983, Effect of arm position and arm support on indirect blood pressure measurements made in a dental chair., J Am Dent Assoc, 106, 645, 10.14219/jada.archive.1983.0146 · DOI
- Ishigami, 2023, Effects of cuff size on the accuracy of blood pressure readings: the Cuff(SZ) randomized crossover trial., JAMA Intern Med, 183, 1061, 10.1001/jamainternmed.2023.3264 · DOI · Paper page
- Brady, 2021, Effects of different rest period durations prior to blood pressure measurement: the best rest trial., Hypertension, 78, 1511, 10.1161/HYPERTENSIONAHA.121.17496 · DOI
- Alpert, 2018, Validation of the Welch Allyn Pro BP 2000, a professional-grade inflation-based automated sphygmomanometer with arrhythmia detection in a combined pediatric and adult population by ANSI/AAMI/ISO standard testing., Blood Press Monit, 23, 315, 10.1097/MBP.0000000000000350 · DOI
- Olufsen, 2005, Blood pressure and blood flow variation during postural change from sitting to standing: model development and validation., J Appl Physiol (1985), 99, 1523, 10.1152/japplphysiol.00177.2005 · DOI · Paper page
- Netea, 2003, Both body and arm position significantly influence blood pressure measurement., J Hum Hypertens, 17, 459, 10.1038/sj.jhh.1001573 · DOI
- Reeves, 1995, The rational clinical examination: does this patient have hypertension? how to measure blood pressure., JAMA, 273, 1211, 10.1001/jama.1995.03520390071036 · DOI
- Smith, 1987, Effect of muscle tension on the cardiovascular responses to lower body negative pressure in man., Med Sci Sports Exerc, 19, 436, 10.1249/00005768-198710000-00003 · DOI · Paper page
- France, 2006, Blood pressure and cerebral oxygenation responses to skeletal muscle tension: a comparison of two physical maneuvers to prevent vasovagal reactions., Clin Physiol Funct Imaging, 26, 21, 10.1111/j.1475-097X.2005.00642.x · DOI
- Mourad, 2004, Arm position and blood pressure: an audit., Intern Med J, 34, 290, 10.1111/j.1444-0903.2004.00592.x · DOI
- Ahmad, 2017, Validity of cardiovascular data from electronic sources: the multi-ethnic study of atherosclerosis and HealthLNK., Circulation, 136, 1207, 10.1161/CIRCULATIONAHA.117.027436 · DOI · Paper page
- Appel, 2011, Improving the measurement of blood pressure: is it time for regulated standards?, Ann Intern Med, 154, 838, 10.7326/0003-4819-154-12-201106210-00014 · DOI · Paper page
- Krist, 2021, Screening for hypertension in adults: US Preventive Services Task Force reaffirmation recommendation statement., JAMA, 325, 1650, 10.1001/jama.2021.4987 · DOI · Paper page
- Green, 2022, Clinic, home, and kiosk blood pressure measurements for diagnosing hypertension: a randomized diagnostic study., J Gen Intern Med, 37, 2948, 10.1007/s11606-022-07400-z · DOI
Cited by
Goupil, R., Tsuyuki, R. T., Santesso, N., Terenzi, K. A., Habert, J., Cheng, G., Gysel, S. C., Bruneau, J., Leung, A. A., Campbell, N. R. C., et al. (2025) · Canadian Medical Association Journal · doi:10.1503/cmaj.241770 · Cited by 60
Metadata
- Authors
- Liu, H., Zhao, D., Sabit, A., Pathiravasan, C. H., Ishigami, J., Charleston, J., Miller, E. R., Matsushita, K., Appel, L. J., & Brady, T. M.
- Affiliations
- Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
- Department of Biostatistics, Johns Hopkins Bloomberg School of Public Health, Baltimore, Maryland
- Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, Maryland
- Venue
- JAMA Internal Medicine
- Publisher
- American Medical Association (AMA)
- Published
- 2024-12-01
- Volume
- 184
- Issue
- 12
- Pages
- 1436
- ISSN
- 2168-6106
- Cited by
- 44
- References
- 5
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.