Importance: Sentinel lymph node (SLN) mapping agents approved for current surgical practice lack sufficient brightness and target specificity for high-contrast, sensitive nodal visualization. Objective: To evaluate whether an ultrasmall, molecularly targeted core-shell silica nanoparticle (Cornell prime dots) can safely and reliably identify optically avid SLNs in head and neck melanoma during fluorescence-guided biopsy. Design, Setting, and Participants: This nonrandomized clinical trial enrolled patients aged 18 years or older with histologically confirmed melanoma in whom SLN mapping was indicated. Exclusion criteria included known pregnancy, breast-feeding, or medical illness unrelated to the tumor. The trial was conducted between February 2015 and March 2018 at Memorial Sloan Kettering Cancer Center, with postoperative follow-up of 2 years. Data analysis was conducted from February 2015 to March 2018. Interventions: Patients received standard-of-care technetium Tc 99m sulfur colloid followed by a microdose administration of integrin-targeting, dye-encapsulated nanoparticles, surface modified with polyethylene glycol chains and cyclic arginine-glycine-aspartic acid-tyrosine peptides (cRGDY-PEG-Cy5.5-nanoparticles) intradermally. Main Outcomes and Measures: The primary end points were safety, procedural feasibility, lowest particle dose and volume for maximizing nodal fluorescence signal, and proportion of nodes identified by technetium Tc 99m sulfur colloid that were optically visualized by cRGDY-PEG-Cy5.5-nanoparticles. Secondary end points included proportion of patients in whom the surgical approach or extent of dissection was altered because of nodal visualization. Results: Of 24 consecutive patients enrolled (median [interquartile range] age, 64 [51-71] years), 18 (75%) were men. In 24 surgical procedures, 40 SLNs were excised. Preoperative localization of SLNs with technetium Tc 99m sulfur colloid was followed by particle dose-escalation studies, yielding optimized doses and volumes of 2 nmol and 0.4 mL, respectively, and maximum SLN signal-to-background ratios of 40. No adverse events were observed. The concordance rate of evaluable SLNs by technetium Tc 99m sulfur colloid and cRGDY-PEG-Cy5.5-nanoparticles was 90% (95% CI, 74%-98%), 5 of which were metastatic. Ultrabright nanoparticle fluorescence enabled high-sensitivity SLN visualization (including difficult-to-access anatomic sites), deep tissue imaging, and, in some instances, detection through intact skin, thereby facilitating intraoperative identification without extensive dissection of adjacent normal tissue or nerves. Conclusions and Relevance: This study found that nanoparticle-based fluorescence-guided SLN biopsy in head and neck melanoma was feasible and safe. This technology holds promise for improving lymphatic mapping and SLN biopsy procedures, while potentially mitigating procedural risks. This study serves as a first step toward developing new multimodal approaches for perioperative care. Trial Registration: ClinicalTrials.gov Identifier: NCT02106598.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamanetworkopen.2021.1936

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 115

Metadata

Authors
Zanoni, D. K., Stambuk, H. E., Madajewski, B., Montero, P. H., Matsuura, D., Busam, K. J., Ma, K., Turker, M. Z., Sequeira, S., Gonen, M., Zanzonico, P., Wiesner, U., Bradbury, M. S., & Patel, S. G.
Venue
JAMA Network Open
Published
2021-03-18
Volume
4
Issue
3
Pages
e211936
ISSN
2574-3805 (ISSN-L)
OpenAlex
W3138703423
Cited by
115
References
0
FWCI
6.44
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of Ultrasmall Core-Shell Fluorescent Silica Nanoparticles for Image-Guided Sentinel Lymph Node Biopsy in Head and Neck Melanoma: A Nonrandomized Clinical Trial. https://app.cochat.ai/papers/10.1001/jamanetworkopen.2021.1936
The paper
Zanoni, D. K., Stambuk, H. E., Madajewski, B., Montero, P. H., Matsuura, D., Busam, K. J., Ma, K., Turker, M. Z., Sequeira, S., Gonen, M., Zanzonico, P., Wiesner, U., Bradbury, M. S., & Patel, S. G. (2021). Use of Ultrasmall Core-Shell Fluorescent Silica Nanoparticles for Image-Guided Sentinel Lymph Node Biopsy in Head and Neck Melanoma: A Nonrandomized Clinical Trial. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2021.1936

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.