Association Between Electronic Health Record Time and Quality of Care Metrics in Primary Care

Open access
Rotenstein, Lisa S., Holmgren, A. Jay, Healey, Michael J., Horn, Daniel M., Ting, David Y., Lipsitz, Stuart, Salmasian, Hojjat, Gitomer, Richard, Bates, David W. · 2022 · JAMA Network Open
Cited by 56

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Importance: Physicians across the US spend substantial time working in the electronic health record (EHR), with primary care physicians (PCPs) spending the most time. The association between EHR time and ambulatory care quality outcomes is unclear. Objective: To characterize measures of EHR use and ambulatory care quality performance among PCPs. Design, Setting, and Participants: A cross-sectional study of PCPs with longitudinal patient panels using a single EHR vendor was conducted at Brigham and Women’s Hospital and Massachusetts General Hospital during calendar year 2021. Exposures: Independent variables included PCPs demographic and practice characteristics and EHR time measures (PCP-level mean of daily total EHR time, after-hours time, time from 5:30 pm to 7:00 am and time on weekends, and daily EHR time on notes, sending and receiving patient, staff, results, prescription, or system messages [in-basket], and clinical review). Main Outcomes and Measures: Outcome variables were ambulatory quality measures (year-end, PCP panel–level achievement of targets for hemoglobin A 1c level control, lipid management, hypertension control, diabetes screening, and breast cancer screening). Results: The sample included 291 physicians (174 [59.8%] women). Median panel size was 829 (IQR, 476-1157) patients and mean (SD) clinical full-time equivalent was 0.54 (0.27). The PCPs spent a mean (SD) of 145.9 (64.6) daily minutes on the EHR. There were significant associations between EHR time and panel-level achievement of hemoglobin A 1c control, hypertension control, and breast cancer screening targets. In adjusted analyses, each additional 15 minutes of total daily EHR time was associated with 0.58 (95% CI, 0.32-0.84) percentage point greater panel-level hemoglobin A 1c control, 0.52 (95% CI, 0.33-0.71) percentage point greater hypertension control, and 0.28 (95% CI, 0.05-0.52) higher breast cancer screening rates. Each daily additional 15 minutes of in-basket time was associated with 2.26 (95% CI, 1.05-3.48) greater panel-wide hemoglobin A 1c control, 1.65 (95% CI, 0.83-2.47) percentage point greater hypertension control, and 1.26 (95% CI, 0.51-2.02) percentage point higher breast cancer screening rates. Associations were largely concentrated among PCPs with 0.5 clinical full-time equivalent or less. There were no associations between EHR use metrics and diabetes screening or lipid management in patients with cardiovascular disease. Conclusions and Relevance: This cross-sectional study found an association between EHR time and some measures of ambulatory care quality. Although increased EHR time is associated with burnout, it may represent a level of thoroughness or communication that enhances certain outcomes. It may be useful for future studies to characterize payment models, workflows, and technologies that enable high-quality ambulatory care delivery while minimizing EHR burden.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamanetworkopen.2022.37086

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 56

Metadata

Authors
Rotenstein, L. S., Holmgren, A. J., Healey, M. J., Horn, D. M., Ting, D. Y., Lipsitz, S., Salmasian, H., Gitomer, R., & Bates, D. W.
Venue
JAMA Network Open
Published
2022-10-18
Volume
5
Issue
10
Pages
e2237086
ISSN
2574-3805 (ISSN-L)
OpenAlex
W4306729749
Cited by
56
References
1
FWCI
7.57
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.