Characterization of the Choroid-Scleral Junction and Suprachoroidal Layer in Healthy Individuals on Enhanced-Depth Imaging Optical Coherence Tomography
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Accurate measurements of choroidal thickness (CT) using enhanced-depth imaging optical coherence tomography (EDI-OCT) require a well-defined choroid-scleral junction (CSJ), which may appear in some eyes as a hyporeflective band corresponding to the suprachoroidal layer (SCL). OBJECTIVE: To identify factors associated with the presence and thickness of the SCL in healthy participants and determine how different CSJ boundary definitions impact CT measurements. DESIGN, SETTING, AND PARTICIPANTS: Secondary analysis of EDI-OCT images obtained prospectively from 74 eyes of 74 controls (mean age, 68.6 years) from the Age-Related Eye Disease Study 2 Ancillary SDOCT Study. MAIN OUTCOMES AND MEASURES: The CSJ appearances were categorized as either having no visible SCL or a hyporeflective band corresponding to the SCL. Ocular parameters associated with the presence and thickness of the SCL were identified. Subfoveal CT was measured using 3 different posterior boundaries: (1) the posterior vessel border (vascular CT [VCT]), (2) inner border of the SCL (stromal CT [StCT]), and (3) inner border of the sclera (total CT [TCT]). Manual segmentation using custom software was used to compare VCT, StCT, and TCT across the macula. RESULTS The SCL was visible in 33 eyes (44.6%). Factors associated with SCL presence and thickness included hyperopic refractive error (R2 = 0.123; P = .045) and increased TCT (R2 = 0.215; P = .004), but not age, visual acuity, intraocular pressure, retinal foveal thickness, VCT, or StCT. In eyes where the SCL was not visible, mean [SD] subfoveal VCT was 222.3 [101.5] μm and StCT and TCT were 240.0 [99.0] μm, with a difference of 17.7 [16.0] μm (P < .001). In eyes where the SCL was visible, mean [SD] subfoveal VCT, StCT, and TCT were 221.9 [83.1] μm, 257.7 [97.3] μm, and 294.1 [104.8] μm, respectively, with the greatest difference of 72.2 [30.4] μm between VCT and TCT (P < .001). All 3 CT measurements were significantly different along all points up to 3.0 mm nasal and temporal to the fovea. CONCLUSIONS AND RELEVANCE: A hyporeflective SCL is visible at the CSJ on EDI-OCT in nearly half of healthy individuals, and its presence correlates with hyperopia. Different posterior boundary definitions may result in significant differences in CT measurements and should be explicitly identified in future choroidal studies and segmentation algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Cited by
Exploring choroidal angioarchitecture in health and disease using choroidal vascularity index
Agrawal, R., Ding, J., Sen, P., Rousselot, A., Chan, A., Nivison-Smith, L., Wei, X., Mahajan, S., Kim, R., Mishra, C., et al. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100829 · Cited by 255
Yiu, G., Chung, S. H., Mollhoff, I. N., Nguyen, U. T., Thomasy, S. M., Yoo, J., Taraborelli, D., & Noronha, G. (2020) · Molecular Therapy - Methods & Clinical Development · doi:10.1016/j.omtm.2020.01.002 · Cited by 153
Self-citationReview of gene therapies for age-related macular degeneration
Khanani, A. M., Thomas, M. J., Aziz, A. A., Weng, C. Y., Danzig, C. J., Yiu, G., Kiss, S., Waheed, N. K., & Kaiser, P. K. (2022) · Eye · doi:10.1038/s41433-021-01842-1 · Cited by 119
Self-citationThe suprachoroidal space: from potential space to a space with potential
Moisseiev, E., Loewenstein, A., & Yiu, G. (2016) · Clinical Ophthalmology · doi:10.2147/opth.s89784 · Cited by 76
Self-citationDrug delivery via the suprachoroidal space for the treatment of retinal diseases
Naftali Ben Haim, L., & Moisseiev, E. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13070967 · Cited by 68
“The SCS is not visualized in all healthy patients, and is generally absent in the eyes of young, healthy persons [21,22].”
Background
Metadata
- Authors
- Yiu, G., Pecen, P., Sarin, N., Chiu, S. J., Farsiu, S., Mruthyunjaya, P., & Toth, C. A.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2014-02-01
- Volume
- 132
- Issue
- 2
- Pages
- 174
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2164108175
- Cited by
- 114
- References
- 2
- FWCI
- 9.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of the Choroid-Scleral Junction and Suprachoroidal Layer in Healthy Individuals on Enhanced-Depth Imaging Optical Coherence Tomography. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2013.7288
- The paper
- Yiu, G., Pecen, P., Sarin, N., Chiu, S. J., Farsiu, S., Mruthyunjaya, P., & Toth, C. A. (2014). Characterization of the Choroid-Scleral Junction and Suprachoroidal Layer in Healthy Individuals on Enhanced-Depth Imaging Optical Coherence Tomography. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2013.7288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.