The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Visualization of 3 Distinct Retinal Plexuses by Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy
Open accessAbstract
IMPORTANCE: Projection artifacts in optical coherence tomography angiography (OCTA) blur the retinal vascular plexuses together and limit visualization of the individual plexuses. OBJECTIVE: To describe projection-resolved (PR) OCTA in eyes with diabetic retinopathy (DR) and healthy eyes. DESIGN, SETTING, AND PARTICIPANTS: In this case-control study, patients with DR and healthy controls were enrolled in this observational study from January 26, 2015, to December 4, 2015, at a tertiary academic center. Spectral-domain, 70-kHz OCT obtained 3 × 3-mm macular scans. The PR algorithm suppressed projection artifacts. A semiautomated segmentation algorithm divided PR-OCTA into superficial, intermediate, and deep retinal plexuses. Two masked graders examined 3-layer PR-OCTA and combined angiograms for nonperfusion and abnormal capillaries. MAIN OUTCOMES AND MEASURES: Retinal nonperfusion and capillary abnormalities and the diagnostic accuracy of detecting DR. RESULTS: Twenty-nine eyes of 15 healthy individuals (mean [SD] age, 36.2 [13.4] years; 11 women) and 47 eyes of 29 patients with DR (mean [SD] age, 55.5 [11.9]; 10 women) underwent imaging. PR-OCTA revealed 3 distinct retinal plexuses in their known anatomical locations in all eyes. The intermediate and deep plexuses of healthy eyes revealed capillary networks of uniform density and caliber, whereas the superficial plexus revealed vessels in the familiar centripetal branching pattern. In eyes with DR, 3-layer PR-OCTA disclosed incongruent areas of nonperfusion and varied vessel caliber and density in the deeper plexuses. Masked grading of capillary nonperfusion on 3-layer PR-OCTA detected DR with 100% sensitivity (95% CI, 90.8%-100%) and 100% specificity (95% CI, 85.4%-100%). With unsegmented retinal angiograms, the sensitivity and specificity were 78.7% (95% CI, 63.9%-88.8%) and 100% (95% CI, 85.4%-100%), respectively (P = .002 for sensitivity). On 3-layer PR-OCTA, sensitivity was 72.2% (95% CI, 54.6%-85.2%) for severe nonproliferative DR and proliferative DR eyes with generalized nonperfusion in 2 or more individual plexuses, but on combined angiogram, sensitivity was 25.0% (95% CI, 12.7%-42.5%) for generalized nonperfusion (P < .001). PR-OCTA disclosed dilated vessels in the intermediate and deep plexuses in 23 eyes (100%) with proliferative DR, 13 eyes (100%) with severe nonproliferative DR, 8 eyes (73%) with mild to moderate nonproliferative DR, and 0 control eyes. CONCLUSIONS AND RELEVANCE: By presenting 3 retinal vascular plexuses distinctly, PR-OCTA reveals capillary abnormalities in deeper layers with clarity and may distinguish DR from healthy eyes and severe DR from mild DR with greater accuracy compared with conventional OCTA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cited by
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Diabetic Retinopathy Preferred Practice Pattern®
Flaxel, C. J., Adelman, R. A., Bailey, S. T., Fawzi, A., Lim, J. I., Vemulakonda, G. A., & Ying, G.-S. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.09.025 · Cited by 717
Self-citationMechanisms of macular edema: Beyond the surface
Daruich, A., Matet, A., Moulin, A., Kowalczuk, L., Nicolas, M., Sellam, A., Rothschild, P.-R., Omri, S., Gélizé, E., Jonet, L., et al. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.006 · Cited by 708
Sampson, D. M., Gong, P., An, D., Menghini, M., Hansen, A., Mackey, D. A., Sampson, D. D., & Chen, F. K. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-21551 · Cited by 298
Metadata
- Authors
- Hwang, T. S., Zhang, M., Bhavsar, K., Zhang, X., Campbell, J. P., Lin, P., Bailey, S. T., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Huang, D., & Jia, Y.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2016-12-01
- Volume
- 134
- Issue
- 12
- Pages
- 1411
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2547715479
- Cited by
- 195
- References
- 1
- FWCI
- 24.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Visualization of 3 Distinct Retinal Plexuses by Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2016.4272
- The paper
- Hwang, T. S., Zhang, M., Bhavsar, K., Zhang, X., Campbell, J. P., Lin, P., Bailey, S. T., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Huang, D., & Jia, Y. (2016). Visualization of 3 Distinct Retinal Plexuses by Projection-Resolved Optical Coherence Tomography Angiography in Diabetic Retinopathy. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2016.4272
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.