Continued Increase of Axial Length and Its Risk Factors in Adults With High Myopia
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
IMPORTANCE: Pathologic myopia due to an excessive increase of axial length is associated with severe visual impairments. Systematic analyses to determine the rate of and the risk factors associated with the axial elongation in adults with high myopia based on long-term follow-up of a large population are needed. OBJECTIVE: To determine the risk factors associated with axial elongation in adults with high myopia. DESIGN, SETTING, AND PARTICIPANTS: This cohort study used the medical records of 43 201 patient visits in a single-hospital database that were collected from January 3, 2011, to December 28, 2018. A total of 15 745 medical records with the patients' sex, best-corrected visual acuity (BCVA), axial length, type of myopic maculopathy, and the presence or absence of choroidal neovascularization (CNV) were reviewed. Data were analyzed from April 3, 2019, to August 5, 2020. MAIN OUTCOMES AND MEASURES: Changes in the axial length at each examination were calculated. The significance of the associations between the annual increase of the axial length and age, sex, baseline axial length, types of myopic maculopathy, and a history of CNV was determined. Generalized linear mixed models were used to evaluate the strength of the risk factors associated with an increase of the axial length in high myopia. RESULTS: Among 1877 patients with 9161 visits included in the analysis, the mean (SD) age was 62.10 (12.92) years, and 1357 (72.30%) were women. The mean (SD) axial length was 29.66 (2.20) mm with a mean (SD) growth rate of 0.05 (0.24) mm/y. Among the 9161 visits, 7096 eyes (77.46%) had myopic maculopathy and 2477 eyes (27.04%) had CNV. The odds ratio for inducing a severe elongation of the axial length was 1.46 (95% CI, 1.38-1.55) for female sex, 0.44 (95% CI, 0.35-0.56) to 0.63 (95% CI, 13 0.50-0.78) for older than 40 years, 1.33 (95% CI, 1.15-1.54) for BCVA of less than 20/400, 1.67 (95% CI, 1.54-1.81) to 2.67 (95% CI, 2.46-2.88) for baseline axial length of 28.15 mm or greater, 1.06 (95% CI, 0.96-1.17) to 1.39 (95% CI, 1.24-1.55) for the presence of maculopathy, and 1.37 (95% CI, 1.29-1.47) for prior CNV. CONCLUSIONS AND RELEVANCE: This cohort study found continuing axial elongation in adults with high myopia. The risk factors for elongation do not appear to be modifiable, so prevention of myopia may be the best approach to reduce the incidence of pathologic myopia and its complications in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Metadata
- Authors
- Du, R., Xie, S., Igarashi-Yokoi, T., Watanabe, T., Uramoto, K., Takahashi, H., Nakao, N., Yoshida, T., Fang, Y., & Ohno-Matsui, K.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2021-10-01
- Volume
- 139
- Issue
- 10
- Pages
- 1096
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W3193629275
- Cited by
- 178
- References
- 1
- FWCI
- 10.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continued Increase of Axial Length and Its Risk Factors in Adults With High Myopia. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2021.3303
- The paper
- Du, R., Xie, S., Igarashi-Yokoi, T., Watanabe, T., Uramoto, K., Takahashi, H., Nakao, N., Yoshida, T., Fang, Y., & Ohno-Matsui, K. (2021). Continued Increase of Axial Length and Its Risk Factors in Adults With High Myopia. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2021.3303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.