CoChat

Detecting Anomalies in Retinal Diseases Using Generative, Discriminative, and Self-supervised Deep Learning

Open access
Burlina, Philippe, Paul, William, Liu, T. Y. Alvin, Bressler, Neil M. · 2022 · JAMA Ophthalmology
Cited by 37

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Anomaly detectors could be pursued for retinal diagnoses based on artificial intelligence systems that may not have access to training examples for all retinal diseases in all phenotypic presentations. Possible applications could include screening of population for any retinal disease rather than a specific disease such as diabetic retinopathy, detection of novel retinal diseases or novel presentations of common retinal diseases, and detection of rare diseases with little or no data available for training. OBJECTIVE: To study the application of anomaly detection to retinal diseases. DESIGN, SETTING, AND PARTICIPANTS: High-resolution retinal images from the publicly available EyePACS data set with fundus images with a corresponding label ranging from 0 to 4 for representing different severities of diabetic retinopathy. Sixteen variants of anomaly detectors were designed. For evaluation, a surrogate problem was constructed, using diabetic retinopathy images, in which only retinas with nonreferable diabetic retinopathy, ie, no diabetic macular edema, and no diabetic retinopathy or mild to moderate nonproliferative diabetic retinopathy were used for training an artificial intelligence system, but both nonreferable and referable diabetic retinopathy (including diabetic macular edema or proliferative diabetic retinopathy) were used to test the system for detecting retinal disease. MAIN OUTCOMES AND MEASURES: Anomaly detectors were evaluated by commonly accepted performance metrics, including area under the receiver operating characteristic curve, F1 score, and accuracy. RESULTS: A total of 88 692 high-resolution retinal images of 44 346 individuals with varying severity of diabetic retinopathy were analyzed. The best performing across all anomaly detectors had an area under the receiver operating characteristic of 0.808 (95% CI, 0.789-0.827) and was obtained using an embedding method that involved a self-supervised network. CONCLUSIONS AND RELEVANCE: This study suggests when abnormal (diseased) data, ie, referable diabetic retinopathy in this study, were not available for training of retinal diagnostic systems wherein only nonreferable diabetic retinopathy was used for training, anomaly detection techniques were useful in identifying images with and without referable diabetic retinopathy. This suggests that anomaly detectors may be used to detect retinal diseases in more generalized settings and potentially could play a role in screening of populations for retinal diseases or identifying novel diseases and phenotyping or detecting unusual presentations of common retinal diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaophthalmol.2021.5557

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 37

Metadata

Authors
Burlina, P., Paul, W., Liu, T. Y. A., & Bressler, N. M.
Venue
JAMA Ophthalmology
Published
2022-02-01
Volume
140
Issue
2
Pages
185
ISSN
2168-6165 (ISSN-L)
OpenAlex
W4200331648
Cited by
37
References
1
FWCI
3.04
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detecting Anomalies in Retinal Diseases Using Generative, Discriminative, and Self-supervised Deep Learning. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2021.5557
The paper
Burlina, P., Paul, W., Liu, T. Y. A., & Bressler, N. M. (2022). Detecting Anomalies in Retinal Diseases Using Generative, Discriminative, and Self-supervised Deep Learning. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2021.5557

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.