CoChat

Transoral Robotic Surgery for Obstructive Sleep Apnea: Perioperative Management and Postoperative Complications

Glazer, Tiffany A., Hoff, Paul T., Spector, Matthew E. · 2014 · JAMA Otolaryngology–Head & Neck Surgery
Cited by 46

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

IMPORTANCE: Patients who undergo surgery for obstructive sleep apnea (OSA) have acceptable perioperative morbidity that is similar to that seen in other sleep-related surgical procedures. OBJECTIVE: To perform the first large-scale evaluation of perioperative management and postoperative complications in patients who undergo transoral robotic surgery (TORS) for OSA. DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort study from 2010 to 2013 of 166 adult patients with moderate to severe OSA (defined as apnea-hypopnea index, >20) who had experienced failure of conventional therapy with positive airway pressure and underwent TORS at an academic practice with follow-up greater than 3 months. INTERVENTIONS: Transoral robotic surgery with or without additional multilevel airway procedures. MAIN OUTCOMES AND MEASURES: Major and minor complication rates. RESULTS: There were 122 men and 44 women with a mean (SD) age of 54.6 (12.3) years. The mean (SD) American Society of Anesthesiologists (ASA) score was 2.3 (0.5). There were 11 major complications, including secondary bleeding requiring intervention (7 patients), pulmonary embolism requiring anticoagulation therapy (2 patients), aspiration requiring prolonged hospitalization (1 patient), and dysphagia resulting in gastrostomy tube dependence (1 patient). There were 32 minor complications, including dehydration and/or uncontrolled pain (16 patients), globus sensation (8 patients), bleeding (5 patients), lip burn (2 patients), and pharyngeal laceration during intubation (1 patient); the majority resolved without sequelae. Preoperative ASA score (P = .003) and number of procedures performed (P = .004) predicted a postoperative complication. Age (P = .29), body mass index (P = .55), apnea-hypopnea index (P = .67), lowest arterial oxygen saturation (P = .63), number of comorbidities (P = .46), and individual comorbidities did not predict a complication. CONCLUSIONS AND RELEVANCE: Transoral robotic surgery can be safely performed in patients with OSA with an acceptable complication rate. Complications are similar to those seen with other surgical treatments of OSA and were only predicted by ASA score and number of procedures performed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1001/jamaoto.2014.2299

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 46

Metadata

Authors
Glazer, T. A., Hoff, P. T., & Spector, M. E.
Venue
JAMA Otolaryngology–Head & Neck Surgery
Published
2014-12-01
Volume
140
Issue
12
Pages
1207
ISSN
2168-6181 (ISSN-L)
OpenAlex
W2101421409
Cited by
46
References
4
FWCI
3.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transoral Robotic Surgery for Obstructive Sleep Apnea: Perioperative Management and Postoperative Complications. https://app.cochat.ai/papers/10.1001/jamaoto.2014.2299
The paper
Glazer, T. A., Hoff, P. T., & Spector, M. E. (2014). Transoral Robotic Surgery for Obstructive Sleep Apnea: Perioperative Management and Postoperative Complications. JAMA Otolaryngology–Head & Neck Surgery. https://doi.org/10.1001/jamaoto.2014.2299

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.