The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
The Use of Computed Tomography in Pediatrics and the Associated Radiation Exposure and Estimated Cancer Risk
Open accessAbstract
IMPORTANCE: Increased use of computed tomography (CT) in pediatrics raises concerns about cancer risk from exposure to ionizing radiation. OBJECTIVES: To quantify trends in the use of CT in pediatrics and the associated radiation exposure and cancer risk. DESIGN: Retrospective observational study. SETTING: Seven US health care systems. PARTICIPANTS: The use of CT was evaluated for children younger than 15 years of age from 1996 to 2010, including 4 857 736 child-years of observation. Radiation doses were calculated for 744 CT scans performed between 2001 and 2011. MAIN OUTCOMES AND MEASURES: Rates of CT use, organ and effective doses, and projected lifetime attributable risks of cancer. RESULTS The use of CT doubled for children younger than 5 years of age and tripled for children 5 to 14 years of age between 1996 and 2005, remained stable between 2006 and 2007, and then began to decline. Effective doses varied from 0.03 to 69.2 mSv per scan. An effective dose of 20 mSv or higher was delivered by 14% to 25% of abdomen/pelvis scans, 6% to 14% of spine scans, and 3% to 8% of chest scans. Projected lifetime attributable risks of solid cancer were higher for younger patients and girls than for older patients and boys, and they were also higher for patients who underwent CT scans of the abdomen/pelvis or spine than for patients who underwent other types of CT scans. For girls, a radiation-induced solid cancer is projected to result from every 300 to 390 abdomen/pelvis scans, 330 to 480 chest scans, and 270 to 800 spine scans, depending on age. The risk of leukemia was highest from head scans for children younger than 5 years of age at a rate of 1.9 cases per 10 000 CT scans. Nationally, 4 million pediatric CT scans of the head, abdomen/pelvis, chest, or spine performed each year are projected to cause 4870 future cancers. Reducing the highest 25% of doses to the median might prevent 43% of these cancers. CONCLUSIONS AND RELEVANCE: The increased use of CT in pediatrics, combined with the wide variability in radiation doses, has resulted in many children receiving a high-dose examination. Dose-reduction strategies targeted to the highest quartile of doses could dramatically reduce the number of radiation-induced cancers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 1×
“This is especially concerning for children because they are more sensitive to radiation-induced carcinogenesis and have many remaining years of life left for cancer to develop.(3,12,13) A recent study(14) in the United Kingdom found that children who received an active bone marrow dose from CT of 30 mGy or higher were…”
BackgroundSmith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Self-citationHealth Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
Berrington de González, A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.440 · Cited by 1,888
Recommendations of the International Commission on Radiological Protection, ICRP Publication 26
Icrp (1977) · Annals of the ICRP · Cited by 1,780
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Kuppermann, N., Holmes, J. F., Dayan, P. S., Hoyle, J. D., Atabaki, S. M., Holubkov, R., Nadel, F. M., Monroe, D., Stanley, R. M., Borgialli, D. A., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61558-0 · Cited by 1,631
Cited by
Lumba-Brown, A., Yeates, K. O., Sarmiento, K., Breiding, M. J., Haegerich, T. M., Gioia, G. A., Turner, M., Benzel, E. C., Suskauer, S. J., Giza, C. C., et al. (2018) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2018.2853 · Cited by 549
The HMO Research Network Virtual Data Warehouse: A Public Data Model to Support Collaboration
Ross, T. R., Ng, D., Brown, J. S., Pardee, R., Hornbrook, M. C., Hart, G., & Steiner, J. F. (2014) · eGEMs (Generating Evidence & Methods to improve patient outcomes) · doi:10.13063/2327-9214.1049 · Cited by 397
Radiation exposure from pediatric CT scans and subsequent cancer risk in The Netherlands
Meulepas, J. M., Ronckers, C. M., Smets, A. M. J. B., Nievelstein, R. A. J., Gradowska, P., Lee, C., Jahnen, A., van Straten, M., de Wit, M.-C. Y., Zonnenberg, B., et al. (2019) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djy104 · Cited by 360
Pediatric Exposures to Ionizing Radiation: Carcinogenic Considerations
Kutanzi, K., Lumen, A., Koturbash, I., & Miousse, I. (2016) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph13111057 · Cited by 287
Hauptmann, M., Byrnes, G., Cardis, E., Bernier, M.-O., Blettner, M., Dabin, J., Engels, H., Istad, T. S., Johansen, C., Kaijser, M., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(22)00655-6 · Cited by 273
Metadata
- Authors
- Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., & Smith-Bindman, R.
- Venue
- JAMA Pediatrics
- Publisher
- American Medical Association (AMA)
- Published
- 2013-08-01
- Volume
- 167
- Issue
- 8
- Pages
- 700
- ISSN
- 1072-4710 (ISSN-L)
- 2168-6203
- OpenAlex
- W2142858362
- Cited by
- 1,476
- References
- 46
- FWCI
- 82.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Use of Computed Tomography in Pediatrics and the Associated Radiation Exposure and Estimated Cancer Risk. https://app.cochat.ai/papers/10.1001/jamapediatrics.2013.311
- The paper
- Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., & Smith-Bindman, R. (2013). The Use of Computed Tomography in Pediatrics and the Associated Radiation Exposure and Estimated Cancer Risk. JAMA Pediatrics. https://doi.org/10.1001/jamapediatrics.2013.311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.