Fourier Transform Infrared Spectrometry
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
The theory and instrumentation for Fourier transform infrared spectrometry are discussed. These instruments measure infrared spectra of the same quality as spectra measured on grating spectrometers in about one thousandth of the time. Their sensitivity advantage for spectra measured in equal times is between a factor of 10 and 100. Commercial spectrometers are now available from nine vendors in North America. Important areas of chemistry include atmospheric monitoring, surface chemistry, and on-line identification of chromatographically separated materials. Many new biochemical and biomedical applications are also becoming apparent, including investigations of phase transitions in lipids and studies of the biocompatibility of implant polymers.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Frequency combs are powerful tools for precision spectroscopy [249].”
From Integrated photonics on thin-film lithium niobate (2021) · cites this paper as [249]
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Fourier Self-Deconvolution: A Method for Resolving Intrinsically Overlapped Bands
Kauppinen, J. K., Moffatt, D. J., Mantsch, H. H., & Cameron, D. G. (1981) · Applied Spectroscopy · doi:10.1366/0003702814732634 · Cited by 1,301
Fourier Transform Infrared Spectroscopy
Faix, O. (1992) · Springer Series in Wood Science · doi:10.1007/978-3-642-74065-7_16 · Cited by 901
Diffuse reflectance measurements by infrared Fourier transform spectrometry
Fuller, M. P., & Griffiths, P. R. (1978) · Analytical Chemistry · doi:10.1021/ac50035a045 · Cited by 622
Self-citationIntroductory Fourier Transform Spectroscopy
(1972) · Elsevier eBooks · doi:10.1016/b978-0-12-085150-8.x5001-3 · Cited by 591
Chemical infrared Fourier transform spectroscopy
Griffiths, P. R. (1975) · Wiley eBooks · Cited by 334
Self-citationNew apodizing functions for Fourier spectrometry
Norton, R. H., & Beer, R. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000259 · Cited by 318
Fourier Transform Infrared Spectroscopy: Applications to Chemical Systems
Ferraro, J. R., & Basile, L. J. (1978) · Cited by 207
Photoacoustic Fourier Transform Infrared Spectroscopy of Solid Samples
Vidrine, D. W. (1980) · Applied Spectroscopy · doi:10.1366/0003702804730303 · Cited by 146
Transform Techniques in Chemistry
Griffiths, P. R. (1978) · Springer eBooks · doi:10.1007/978-1-4684-2403-4 · Cited by 143
Self-citation
Cited by
Items 901–1,000 of 1,006
Characterization of mid-infrared femtosecond pulses [Invited]
Lee, K. F., Kubarych, K. J., Bonvalet, A., & Joffre, M. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.000a54 · Cited by 32
Development of an in situ spectroscopic method for cleaning validation using mid-IR fiber-optics
Mehta, N. K., Goenaga-Polo, J., Hernández‐Rivera, S. P., Hernández, D., Thomson, M. A., & Melling, P. J. (2002) · Cited by 30
Fourier Transform Flame Infrared Emission Spectroscopy
Tilotta, D. C., Busch, K. W., & BUSCH, M. A. (1989) · Applied Spectroscopy · doi:10.1366/0003702894202454 · Cited by 30
Blanco, A., Juan, R., Paredes, B., Domínguez, C., & García‐Muñoz, R. A. (2025) · Polymer Testing · doi:10.1016/j.polymertesting.2025.108855 · Cited by 29
Musto, P., Martuscelli, E., Ragosta, G., & Russo, P. (2000) · High Performance Polymers · doi:10.1088/0954-0083/12/1/312 · Cited by 29
Amadei, C. A., Santos, S., Pehkonen, S. O., Verdaguer, A., & Chiesa, M. (2013) · The Journal of Physical Chemistry C · doi:10.1021/jp408984h · Cited by 29
Infrared thermography method for fast estimation of phase diagrams
del Barrio, E. P., Cadoret, R., Daranlot, J., & Achchaq, F. (2015) · Thermochimica Acta · doi:10.1016/j.tca.2015.12.010 · Cited by 29
Miniaturizing Fourier Transform Spectrometer With an Electrothermal Micromirror
Wang, W., Samuelson, S. R., Chen, J., & Xie, H. (2015) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2015.2423637 · Cited by 29
Lü, Q., Chen, G., Lin, T.-T., & Yu, Y. (2015) · Composites Science and Technology · doi:10.1016/j.compscitech.2015.05.002 · Cited by 29
Infrared Spectroscopy for Studying Structure and Aging Effects in Rhamnolipid Biosurfactants
Kiefer, J., Radzuan, M. N., & Winterburn, J. B. (2017) · Applied Sciences · doi:10.3390/app7050533 · Cited by 31
“Due to the light-matter-interaction in the evanescent field, the reflected radiation carries information about the absorption spectrum [9].”
BackgroundSun, D., He, L., Chen, R., Lin, Z., Lin, S., Xiao, C., & Lin, B. (2018) · Journal of Materials Chemistry A · doi:10.1039/c8ta07711h · Cited by 29
Manzoli, M. (2019) · Catalysts · doi:10.3390/catal9010030 · Cited by 29
Structural, optical and dielectric studies of Ag nanoparticles decorated by herceptin
Jafarzadeh, N., Nadafan, M., Malekfar, R., Shakeri‐Zadeh, A., Meidanchi, A., & Eynali, S. (2019) · Physica E Low-dimensional Systems and Nanostructures · doi:10.1016/j.physe.2019.113562 · Cited by 29
Bürki, C., Reggente, M., Dillner, A. M., Hand, J. L., Shaw, S. L., & Takahama, S. (2020) · Atmospheric measurement techniques · doi:10.5194/amt-13-1517-2020 · Cited by 31
Transduction Process‐Based Classification of Biosensors
Yang, F., Ma, Y., Stanciu, S. G., & Wu, A. (2020) · Wiley eBooks · doi:10.1002/9783527345137.ch2 · Cited by 31
Advanced DNA Detection via Multispectral Plasmonic Metasurfaces
Meo, V. D., Moccia, M., Sanità, G., Crescitelli, A., Lamberti, A., Galdi, V., Rendina, I., & Esposito, E. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.666121 · Cited by 29
“…due to the possibility to perform high-speed and standard investigations of several compounds, Fourier-transform IR (FTIR) spectroscopy is one of the most employed analysis tools for a wide range of scenarios of both academic and industrial interest (Stuart, 2004; Griffiths et al., 2007).”
BackgroundSpatially Resolved Photochemistry Impacts Emissions Estimates in Fresh Wildfire Plumes
Palm, B. B., Peng, Q., Hall, S. R., Ullmann, K., Campos, T. L., Weinheimer, A. J., Montzka, D. D., Tyndall, G. S., Permar, W., Hu, L., et al. (2021) · Geophysical Research Letters · doi:10.1029/2021gl095443 · Cited by 33
Super-Resolved 3D Mapping of Molecular Orientation Using Vibrational Techniques
Kozioł, P., Kosowska, K., Liberda, D., Borondics, F., & Wróbel, T. P. (2022) · Journal of the American Chemical Society · doi:10.1021/jacs.2c05306 · Cited by 29
Thermal Plasma Spray Deposition of Titanium and Hydroxyapatite on Polyaryletheretherketone Implants
Robotti, P., & Zappini, G. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-4463-7.10009-0 · Cited by 30
Singh, J., & Singh, J. (2006) · Taylor & Francis eBooks · doi:10.4324/9780203974735 · Cited by 29
Toxic potential of copper-doped ZnO nanoparticles inDrosophila melanogaster(Oregon R)
Siddique, Y. H., Haidari, M., Khan, W., Fatima, A., Jyoti, S., Khanam, S., Naz, F., Rahul, R., Ali, F. R., Singh, B. R., et al. (2015) · Toxicology Mechanisms and Methods · doi:10.3109/15376516.2015.1045653 · Cited by 29
Beltrán, V., Salvadó, N., Butí, S., & Cinque, G. (2014) · Microchemical Journal · doi:10.1016/j.microc.2014.09.001 · Cited by 29
Cho, H., Felts, J. R., Yu, M.-F., Bergman, L. A., Vakakis, A. F., & King, W. P. (2013) · Nanotechnology · doi:10.1088/0957-4484/24/44/444007 · Cited by 29
RIR-MAPLE deposition of conjugated polymers for application to optoelectronic devices
Pate, R., McCormick, R., Chen, L., Zhou, W., & Stiff‐Roberts, A. D. (2011) · Applied Physics A · doi:10.1007/s00339-011-6598-3 · Cited by 29
Mattson, E. C., Aboualizadeh, E., Barabas, M. E., Stucky, C. L., & Hirschmugl, C. J. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms141122753 · Cited by 29
Jacquemart, D., Gueye, F., Lyulin, O. M., Karlovets, E. V., Barón, D., & Perevalov, V. I. (2012) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2012.02.020 · Cited by 29
Temperature-dependent absorption cross-sections of HCFC-142b
Bris, K. L., & Strong, K. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.10.005 · Cited by 29
Zhang, W., Ji, J., Zhang, Y., Yan, Q., Kurmaev, E. Z., Moewes, A., Zhao, J. F., & Chu, P. K.-H. (2007) · Applied Surface Science · doi:10.1016/j.apsusc.2007.05.019 · Cited by 29
Impact of Sodium on the Formation Mechanism and Physicochemical Properties of Coal-Derived Soot
Dong, H., Du, Q., Li, D., Feng, D., Gao, J., & Wu, S. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.9b03521 · Cited by 30
Terahertz absorbance spectrum fitting method for quantitative detection of concealed contraband
Wang, Y., Zhao, Z., Chen, Z., Kang, K., Feng, B., & Zhang, Y. (2007) · Journal of Applied Physics · doi:10.1063/1.2821241 · Cited by 31
Studies on the macromolecular components of nonwood available in Bangladesh
Jahan, M. S., & Mun, S. P. (2009) · Industrial Crops and Products · doi:10.1016/j.indcrop.2009.06.006 · Cited by 32
Simultaneous determination of enzyme activities by FTIR-spectroscopy in an one-step assay
Schindler, R., & Lendl, B. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00192-0 · Cited by 29
Optical Spectroscopy in Photosynthetic Antennas
Parson, W. W., & Nagarajan, V. (2003) · Advances in photosynthesis and respiration · doi:10.1007/978-94-017-2087-8_3 · Cited by 29
Infrared line shapes of ethylidyne on the Pt(111) surface
Malik, I. J., Agrawal, V. K., & Trenary, M. (1988) · The Journal of Chemical Physics · doi:10.1063/1.454861 · Cited by 29
Quantum-Enhanced Absorption Spectroscopy with Bright Squeezed Frequency Combs
Belsley, A. (2023) · Physical Review Letters · doi:10.1103/physrevlett.130.133602 · Cited by 30
“We thus avoid the need for multiple sequential measurements as in cavity ring-down spectroscopy [25, 26] or the long acquisition times present in conventional Fourier-transform infrared spectrometers [27].”
MethodAli, A., Chhabra, D., Kumari, M., Manisha, K., Pinkey, Tiwari, S., & Sahdev, R. K. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-024-32171-x · Cited by 31
Mapping chemicals in air using an environmental CAT scanning system: evaluation of algorithms
Samanta, A., & Todd, L. A. (2000) · Atmospheric Environment · doi:10.1016/s1352-2310(99)00331-3 · Cited by 28
Measuring air–sea gas-exchange velocities in a large-scale annular wind–wave tank
Mesarchaki, E., Kräuter, C., Krall, K. E., Bopp, M., Helleis, F., Williams, J., & Jähne, B. (2015) · Ocean science · doi:10.5194/os-11-121-2015 · Cited by 28
“The key aspects of FT-IR spectroscopy are described in detail in Griffiths (2007). In this study, a Nicolet iS10 (manufactured by Thermo Fischer Scientific Inc., Waltham, MA., USA) FT-IR spectrometer with a custom made measuring cell of approximately 5 cm length was used. About every 5 s, one infrared absorbance spect…”
MethodInfluentialLiu, B., Zhang, Y., Su, Z., Li, G., & Jiang, T. (2016) · Powder Technology · doi:10.1016/j.powtec.2016.05.044 · Cited by 28
Root Differentiation of Agricultural Plant Cultivars and Proveniences Using FTIR Spectroscopy
Legner, N., Meinen, C., & Rauber, R. (2018) · Frontiers in Plant Science · doi:10.3389/fpls.2018.00748 · Cited by 28
Jahromi, K. E., Nematollahi, M., Krebbers, R., Abbas, M. A., Khodabakhsh, A., & Harren, F. J. M. (2021) · Optics Express · doi:10.1364/oe.418072 · Cited by 28
Méndez, D. E., & Allscher, T. (2022) · Polymers · doi:10.3390/polym14040808 · Cited by 34
Ryu, J., & Ro, C. (2009) · Analytical Chemistry · doi:10.1021/ac9007545 · Cited by 28
Fourier transform infrared spectroscopy and multivariate analysis of milk from different goat breeds
Salleh, N. A., Selamat, J., Meng, G. Y., Abas, F., Jambari, N. N., & Khatib, A. (2019) · International Journal of Food Properties · doi:10.1080/10942912.2019.1668803 · Cited by 28
“FTIR is a method that predominantly measures the vibrations of chemical bonds within functional groups and generates a spectrum that can be considered as a biochemical or metabolic ‘fingerprint‘ of the sample.([19]) This technology has been used for a wide range of application in milk analysis: quantification of milk…”
MethodSchwaighofer, A., Alcaráz, M. R., Lux, L., & Lendl, B. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117636 · Cited by 28
Shao, L., & Griffiths, P. R. (2008) · Analytical Chemistry · doi:10.1021/ac800522w · Cited by 28
Self-citationMiao, M., Liu, H., Jiang, B., Yang, C., Xia, X., & Zhang, T. (2014) · Journal of Functional Foods · doi:10.1016/j.jff.2014.01.011 · Cited by 28
Methods for the Modification and Characterization of Oxide Surfaces
Pesek, J. J., & Matyska, M. T. (1997) · Interface Science · doi:10.1023/a:1008648923962 · Cited by 28
Analysis of Depth Profiling Data Obtained by Confocal Raman Microspectroscopy
Vyörykkä, J., Paaso, J., Tenhunen, M., Tenhunen, J., Iitti, H., Vuorinen, T., & Stenius, P. J. (2003) · Applied Spectroscopy · doi:10.1366/00037020360695982 · Cited by 28
Finqueneisel, G. (1998) · Fuel · doi:10.1016/s0016-2361(97)00249-4 · Cited by 28
Turula, V. E., & de Haseth, J. A. (1994) · Applied Spectroscopy · doi:10.1366/0003702944027390 · Cited by 28
MAGIC-LC/FT-IR Spectrometry with Buffered Solvent Systems
Robertson, R. M., de Haseth, J. A., & Browner, R. F. (1990) · Applied Spectroscopy · doi:10.1366/0003702904085886 · Cited by 28
Scanning Probe Microscopies for Characterizations of 2D Materials
Su, S., Zhao, J. X., & Ly, T. H. (2024) · Small Methods · doi:10.1002/smtd.202400211 · Cited by 28
Wideband Optical MEMS Interferometer Enabled by Multimode Interference Waveguides
Mortada, B., Erfan, M., Medhat, M., Sabry, Y. M., Saadany, B., & Khalil, D. A. M. (2016) · Journal of Lightwave Technology · doi:10.1109/jlt.2016.2531642 · Cited by 27
Гунько, В. М., Pakhlov, E. M., Skubiszewska-Zięba, J., & Blitz, J. P. (2016) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2016.11.003 · Cited by 27
Goldschmidt, J., Nitzsche, L., Wolf, S., Lambrecht, A., & Wöllenstein, J. (2022) · Sensors · doi:10.3390/s22030857 · Cited by 31
Recent advances in ultrafast plasmonics: from strong field physics to ultraprecision spectroscopy
Kim, S., Jeong, T.-I., Park, J., Ciappina, M. F., & Kim, S. (2022) · Nanophotonics · doi:10.1515/nanoph-2021-0694 · Cited by 35
Faller, L.-M., Mitterer, T., Leitzke, J. P., & Zangl, H. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2771955 · Cited by 27
Pena, R., Lang, C., Naumann, A., & Polle, A. (2014) · Frontiers in Plant Science · doi:10.3389/fpls.2014.00229 · Cited by 27
Development of delayed-release proliposomes tablets for oral protein drug delivery
Tantisripreecha, C., Jaturanpinyo, M., Panyarachun, B., & Sarisuta, N. (2011) · Drug Development and Industrial Pharmacy · doi:10.3109/03639045.2011.623168 · Cited by 27
Navajas, A., Arzamendi, G., Sarria, F. R., Centeno, M. Á., Odriozola, J. A., & Gandía, L. M. (2011) · Catalysis Communications · doi:10.1016/j.catcom.2011.11.005 · Cited by 27
Shao, L., Griffiths, P. R., & Leytem, A. B. (2010) · Analytical Chemistry · doi:10.1021/ac101711r · Cited by 27
Self-citationMid‐infrared spectroscopy‐based analysis of mammalian cell culture Parameters
Capito, F., Zimmer, A., & Skudas, R. (2015) · Biotechnology Progress · doi:10.1002/btpr.2026 · Cited by 25
Hsu, C.-C., Sun, J.-K., Tsao, C.-C., & Chuang, P.-Y. (2017) · Physica B Condensed Matter · doi:10.1016/j.physb.2017.05.040 · Cited by 27
Gas Measurement Using Static Fourier Transform Infrared Spectrometers
Köhler, M. H., Schardt, M., Rauscher, M., & Koch, A. W. (2017) · Sensors · doi:10.3390/s17112612 · Cited by 27
“The linear absorption coefficient is given by α(ν̃) [5].”
BackgroundMethodInfluentialFeng, Q., Cai, H., Hai-ying, L., Siying, Q., Liu, Z., Ma, D., & Ye, Y. (2017) · Nanotechnology · doi:10.1088/1361-6528/aaa1d1 · Cited by 27
Vibrational Spectroscopy Methods for Agro-Food Product Analysis
Roberts, J. J., Power, A., Chapman, J., Chandra, S., & Cozzolino, D. (2018) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2018.03.002 · Cited by 34
The velocity dependence of viscosity of flowing water
Ni, K., Fang, H., Yu, Z., & Fan, Z. (2019) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.01.055 · Cited by 27
“As the resolution of the spectroscopy decreases, those peaks or valleys connect with each other and form an absorption band [47].”
BackgroundHerd health monitoring in dairy farms – discover metabolic diseases. An overview
Gruber, S., & Mansfeld, R. (2019) · Tierärztliche Praxis Ausgabe G Großtiere / Nutztiere · doi:10.1055/a-0949-1637 · Cited by 32
“In summary, this technique impresses because of its cheap, rapid and simple character [26].”
MethodSelf-Organized Nanorod Arrays for Large-Area Surface-Enhanced Infrared Absorption
Giordano, M. C., Tzschoppe, M., Barelli, M., Vogt, J., Huck, C., Canepa, F., Pucci, A., & de Mongeot, F. B. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b19719 · Cited by 28
Identification of three Diospysros species using FT-IR and 2DCOS-IR
Ma, F., Huang, A., Zhang, S., Zhou, Q., & Zhang, Q. (2020) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2020.128709 · Cited by 27
Mostaço-Guidolin, L. B., Murakami, L. S., Sawazaki, M. R. B., Nomizo, A., & Bachmann, L. (2010) · Spectroscopy An International Journal · doi:10.1155/2010/498719 · Cited by 27
Şimşek, S., & Ulusoy, U. (2012) · Reactive and Functional Polymers · doi:10.1016/j.reactfunctpolym.2012.09.003 · Cited by 27
Loring, J. S., Karlsson, M. G., Fawcett, W. R., & Casey, W. H. (2000) · Geochimica et Cosmochimica Acta · doi:10.1016/s0016-7037(00)00499-3 · Cited by 27
Polymer Dispersed Liquid Crystals
Singh, S., Srivastava, J. K., & Singh, R. K. (2015) · Springer eBooks · doi:10.1007/978-3-319-22894-5_7 · Cited by 27
Thermal infrared spectral band detection limits for unidentified surface materials
Kirkland, L. E., Herr, K. C., & Salisbury, J. W. (2001) · Applied Optics · doi:10.1364/ao.40.004852 · Cited by 27
INFRARED STUDIES OF BACTERIORHODOPSIN
Rothschild, K. J. (1988) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1988.tb01671.x · Cited by 27
“capability stems from the extremely high signall noise ratio obtainable with Fourier transform infrared (FTIR) spectroscopy (Griffiths, 1983).”
BackgroundJurowski, K., Noga, M., Kobylarz, D., Niżnik, Ł., & Krośniak, A. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25136884 · Cited by 28
Mediterranean shrublands as carbon sinks for climate change mitigation: new root-to-shoot ratios
Carrión-Prieto, P., Hernández-Navarro, S., Martín‐Ramos, P., Sastre, L., Laurnaga, F. G., Marcos-Robles, J. L., & Martín‐Gil, J. (2017) · Carbon Management · doi:10.1080/17583004.2017.1285178 · Cited by 26
“quantitatively measurable by FTIR spectroscopy [37,38].”
Maphanao, P., Thanan, R., Loilome, W., Chio‐Srichan, S., Wongwattanakul, M., & Sakonsinsiri, C. (2020) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2020.129708 · Cited by 27
Akram, F., Habib, M., Bae, J., Khan, S. A., Choi, S. Y., Ahmed, T., Baek, S.-B., Din, S. T. U., Lim, D.-H., Jeong, S., et al. (2021) · Journal of Materials Science · doi:10.1007/s10853-021-06138-z · Cited by 26
“To clearly understand these issues, this study focuses on structural characterizations (X-ray diffraction-XRD, Raman spectroscopy, Fourier-transform infrared spectroscopy (FTIR), and X-ray photoelectron spectroscopy (XPS) of Fe3? to Fe2? transition and oxygen vacancy (V O ) concentrations.”
MethodInfluentialA Global and Seasonal Perspective of Martian Water Vapor From ExoMars/NOMAD
Crismani, M. M. J., Villanueva, G. L., Liuzzi, G., Smith, M. D., Knutsen, E. W., Daerden, F. W., Neary, L., Mumma, M. J., Aoki, S., Trompet, L., et al. (2021) · Journal of Geophysical Research Planets · doi:10.1029/2021je006878 · Cited by 27
“Once the background is subtracted, this source of noise is the result of quantization that can cause measured values to fluctuate between different quantization levels (Griffiths & Haseth, 2007).”
Poly(vinylidene fluoride‐co‐trifluoroethylene) Thin Films after Dip‐ and Spin‐Coating
Apelt, S., Höhne, S., Mehner, E., Böhm, C., Malanin, M., Eichhorn, K., Jehnichen, D., Uhlmann, P., & Bergmann, U. (2022) · Macromolecular Materials and Engineering · doi:10.1002/mame.202200296 · Cited by 26
Evolution of Structure Properties during Zhundong Coal Pyrolysis
Dong, Q., Zhang, H., & Zhu, Z. (2015) · Procedia Engineering · doi:10.1016/j.proeng.2015.01.101 · Cited by 26
An Effective In Situ Drifts Analysis of the Solid Electrolyte Interface in Lithium-Ion Battery
Haregewoin, A., Shie, T.-D., Lin, S. D., Hwang, B., & Wang, F. (2013) · ECS Transactions · doi:10.1149/05336.0023ecst · Cited by 26
Merschman, S. A., Lubbad, S. H., & Tilotta, D. C. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00800-0 · Cited by 29
Tran, N. L., Hall, D., & Webster, T. J. (2012) · Nanotechnology · doi:10.1088/0957-4484/23/45/455104 · Cited by 35
Li, X., Lu, H., Li, J., & Dong, G. (2018) · Tribology International · doi:10.1016/j.triboint.2018.06.025 · Cited by 27
Song, M., & Li, M. (2019) · Environmental Science and Pollution Research · doi:10.1007/s11356-018-4049-9 · Cited by 27
Umdale, S. D., Ahire, M. L., Aiwale, V., Jadhav, A. D., & Mundada, P. S. (2020) · Biocatalysis and Agricultural Biotechnology · doi:10.1016/j.bcab.2020.101705 · Cited by 26
Siesler, H. W. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.01318-7 · Cited by 26
Near-infrared emission spectrometry measurements for nonintrusive soot diagnostics in flames
Ayrancı, I., Vaillon, R., & Selçuk, N. (2007) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2007.08.013 · Cited by 26
Line mixing in the ν6 Q branches of self- and nitrogen-broadened methyl bromide
Tran, H., Jacquemart, D., Mandin, J.-Y., & Lacome, N. (2007) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2007.05.003 · Cited by 26
“Every scan among the 200 recorded for each spectrum has then been individually transformed to spectrum, using the Fourier transform procedure included in the Bruker software OPUS package [10], selecting a Mertz phase error correction [11,12].”
MethodSmyrl, N. R., Hembree, D. M., Davis, W. E., Williams, D. M., & Vance, J. C. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125636 · Cited by 26
Chaloner, P. A. (1990) · Coordination Chemistry Reviews · doi:10.1016/0010-8545(90)85023-l · Cited by 26
Advances in monitoring and control of refolding kinetics combining PAT and modeling
Pauk, J. N., Raju Palanisamy, J., Kager, J., Koczka, K., Berghammer, G., Herwig, C., & Veiter, L. (2021) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-021-11151-y · Cited by 25
“Thereby, Fourier transformation enables the decomposition of a detector obtained time-domain spectrum into its constituent frequency domain spectra that can be easily interpreted (Griffiths 1983).”
BackgroundFlemban, T. H. (2023) · Journal of Experimental Nanoscience · doi:10.1080/17458080.2023.2175817 · Cited by 28
“When a sample is exposed to infrared light, inelastic collisions between the molecules and infrared photons produce vibrations with a characteristic vibrational frequency and of varying modes depending on the nature of the bond [49].”
BackgroundMa, J., Yan, G., Ma, W., Cheng, C., Wang, Q., & Guo, S. (2015) · Water Air & Soil Pollution · doi:10.1007/s11270-015-2491-6 · Cited by 25
“OH structure in molecule and the absorption band near 2940, 2872, and 1454 cm−1 were attributed to stretching vibration of – CH– in the carbon chain (Griffiths and Haseth 2007; Smith 2011).”
BackgroundDual-comb spectroscopy of molecular electronic transitions in condensed phases
Cho, B., Yoon, T. H., & Cho, M. (2018) · Physical Review A · doi:10.1103/physreva.97.033831 · Cited by 25
Herold, F., Leubner, O., Jeschonek, K., Hess, C. W., Drochner, A., Qi, W., & Etzold, B. J. M. (2021) · Carbon Trends · doi:10.1016/j.cartre.2020.100020 · Cited by 25
Metadata
- Authors
- Griffiths, P. R., & de Haseth, J. A.
- Affiliations
- University of California, Riverside (US)
- Venue
- Wiley eBooks
- Publisher
- Wiley
- Published
- 2006-06-30
- Volume
- 222
- Issue
- 4621
- Pages
- 297-302
- OpenAlex
- W2112531993
- Cited by
- 3,052
- References
- 48
- Citations by year
- 2026: 78 · 2025: 111 · 2024: 106 · 2023: 109 · 2022: 143 · 2021: 154 · 2020: 153 · 2019: 147 · 2018: 162 · 2017: 151 · 2016: 154 · 2015: 153 · 2014: 140 · 2013: 131 · 2012: 118
- FWCI
- 14.59
- Type
- book
- Language
- en
- Open access
- closed
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
- Locations
- Wiley eBooks (publishedVersion)
- PubMed (publishedVersion)
- CERN Document Server (European Organization for Nuclear Research) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Keywords
- FTIR spectroscopy, infrared spectroscopy instrumentation, spectral sensitivity, grating spectrometer, atmospheric monitoring, surface chemistry, chromatographic identification, lipid phase transition
- MeSH terms
- Bacteria, Chromatography, Gas, Fourier Analysis, Lipids, Membranes, Spectrophotometry, Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.