Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 660

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults

Open access
Parker, Martyn J, Handoll, Helen HG·2010·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Two types of implants used for the surgical fixation of extracapsular hip fractures are cephalocondylic intramedullary nails, which are inserted into the femoral canal proximally to distally across the fracture, and extramedullary implants (e.g. the sliding hip screw). OBJECTIVES: To compare cephalocondylic intramedullary nails with extramedullary implants for extracapsular hip fractures in adults. SEARCH STRATEGY: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (April 2010), The Cochrane Central Register of Controlled Trials (The Cochrane Library 2010, Issue 1), MEDLINE (1950 to March 2010), EMBASE (1980 to 2010 Week 13), and other sources. SELECTION CRITERIA: All randomised and quasi-randomised controlled trials comparing cephalocondylic nails with extramedullary implants for extracapsular hip fractures. DATA COLLECTION AND ANALYSIS: Both authors independently assessed trial quality and extracted data. Wherever appropriate, results were pooled. MAIN RESULTS: We included 43 trials containing predominantly older people with mainly trochanteric fractures. Twenty-two trials (3749 participants) compared the Gamma nail with the sliding hip screw (SHS). The Gamma nail was associated with increased risk of operative and later fracture of the femur and increased reoperation rate. There were no major differences between implants in wound infection, mortality or medical complications.Five trials (623 participants) compared the intramedullary hip screw (IMHS) with the SHS. Fracture fixation complications were more common in the IMHS group. Results for post-operative complications, mortality and functional outcomes were similar in both groups.Three trials (394 participants) showed no difference in fracture fixation complications, reoperation, wound infection and length of hospital stay for proximal femoral nail (PFN) versus the SHS.None of the 10 trials (1491 participants) of other nail versus extramedullary implant comparisons for trochanteric fractures provided sufficient evidence to establish definite differences between the implants under test.Two trials (65 participants) found intramedullary nails were associated with fewer fracture fixation complications than fixed nail plates for unstable fractures at the level of the lesser trochanter.Two trials (124 participants) found a tendency to less fracture healing complications with the intramedullary nails compared with fixed nail plates for subtrochanteric fractures. AUTHORS' CONCLUSIONS: With its lower complication rate in comparison with intramedullary nails, and absence of functional outcome data to the contrary, the SHS appears superior for trochanteric fractures. Further studies are required to confirm whether more recently developed designs of intramedullary nail avoid the complications of previous nails. Intramedullary nails may have advantages over fixed angle plates for subtrochanteric and some unstable trochanteric fractures, but further studies are required.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd000093.pub5

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 660

Metadata

Authors
Parker, M. J., & Handoll, H. H.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2010-09-08
Issue
9
Pages
CD000093-CD000093
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2138731297
Cited by
660
References
3
FWCI
47.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. https://app.cochat.ai/papers/10.1002/14651858.cd000093.pub5
The paper
Parker, M. J., & Handoll, H. H. (2010). Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd000093.pub5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.