The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults
Open accessAbstract
BACKGROUND: Two types of implants used for the surgical fixation of extracapsular hip fractures are cephalocondylic intramedullary nails, which are inserted into the femoral canal proximally to distally across the fracture, and extramedullary implants (e.g. the sliding hip screw). OBJECTIVES: To compare cephalocondylic intramedullary nails with extramedullary implants for extracapsular hip fractures in adults. SEARCH STRATEGY: We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (April 2010), The Cochrane Central Register of Controlled Trials (The Cochrane Library 2010, Issue 1), MEDLINE (1950 to March 2010), EMBASE (1980 to 2010 Week 13), and other sources. SELECTION CRITERIA: All randomised and quasi-randomised controlled trials comparing cephalocondylic nails with extramedullary implants for extracapsular hip fractures. DATA COLLECTION AND ANALYSIS: Both authors independently assessed trial quality and extracted data. Wherever appropriate, results were pooled. MAIN RESULTS: We included 43 trials containing predominantly older people with mainly trochanteric fractures. Twenty-two trials (3749 participants) compared the Gamma nail with the sliding hip screw (SHS). The Gamma nail was associated with increased risk of operative and later fracture of the femur and increased reoperation rate. There were no major differences between implants in wound infection, mortality or medical complications.Five trials (623 participants) compared the intramedullary hip screw (IMHS) with the SHS. Fracture fixation complications were more common in the IMHS group. Results for post-operative complications, mortality and functional outcomes were similar in both groups.Three trials (394 participants) showed no difference in fracture fixation complications, reoperation, wound infection and length of hospital stay for proximal femoral nail (PFN) versus the SHS.None of the 10 trials (1491 participants) of other nail versus extramedullary implant comparisons for trochanteric fractures provided sufficient evidence to establish definite differences between the implants under test.Two trials (65 participants) found intramedullary nails were associated with fewer fracture fixation complications than fixed nail plates for unstable fractures at the level of the lesser trochanter.Two trials (124 participants) found a tendency to less fracture healing complications with the intramedullary nails compared with fixed nail plates for subtrochanteric fractures. AUTHORS' CONCLUSIONS: With its lower complication rate in comparison with intramedullary nails, and absence of functional outcome data to the contrary, the SHS appears superior for trochanteric fractures. Further studies are required to confirm whether more recently developed designs of intramedullary nail avoid the complications of previous nails. Intramedullary nails may have advantages over fixed angle plates for subtrochanteric and some unstable trochanteric fractures, but further studies are required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · The Lancet · doi:10.1016/s0140-6736(00)04337-3 · Cited by 5,373
Boutron, I., Moher, D., Altman, D. G., Schulz, K. F., Ravaud, P., & for the CONSORT Group* (2008) · Annals of Internal Medicine · doi:10.7326/0003-4819-148-4-200802190-00008 · Cited by 2,292
Cited by
Nauth, A., Creek, A. T., Zellar, A., Lawendy, A.-R., Dowrick, A., Gupta, A., Dadi, A., van Kampen, A., Yee, A., de Vries, A. C., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30066-1 · Cited by 319
Metadata
- Authors
- Parker, M. J., & Handoll, H. H.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2010-09-08
- Issue
- 9
- Pages
- CD000093-CD000093
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2138731297
- Cited by
- 660
- References
- 3
- FWCI
- 47.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. https://app.cochat.ai/papers/10.1002/14651858.cd000093.pub5
- The paper
- Parker, M. J., & Handoll, H. H. (2010). Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd000093.pub5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.