The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Immediate post-partum insertion of intrauterine devices
Abstract
BACKGROUND: Insertion of an intrauterine device (IUD) immediately after an abortion has several advantages. The woman is known not to be pregnant. Many clinicians refuse to insert an IUD in a woman who is not menstruating. After induced abortion, a woman's motivation to use contraception may be high. However, insertion of an IUD immediately after a pregnancy ends carries risks, such as spontaneous expulsion due to recent cervical dilation. OBJECTIVES: To assess the safety and efficacy of IUD insertion immediately after spontaneous or induced abortion. SEARCH STRATEGY: We searched MEDLINE, CENTRAL, POPLINE, EMBASE, ClinicalTrials.gov, and ICTRP. We also contacted investigators to identify other trials. SELECTION CRITERIA: We sought all randomized controlled trials with at least one treatment arm that involved IUD insertion immediately after an induced abortion or after curettage for spontaneous abortion. We identified 11 trials which described random assignment. DATA COLLECTION AND ANALYSIS: We evaluated the methodological quality of each report and abstracted the data. We focused on discontinuation rates for accidental pregnancy, perforation, expulsion, and pelvic inflammatory disease. We computed the weighted average of the rate ratios. We computed relative risks (RR) with 95% Confidence Intervals (CI). MAIN RESULTS: Three trials randomized to immediate or delayed insertion. One showed no significant differences. Meta-analysis of two showed use of levonorgestrel-releasing intrauterine system or CuT380A was more likely for immediate versus delayed insertion (RR 1.18; 95% CI 1.08 to 1.28). Another trial randomized to the levonorgestrel IUD or Nova T; discontinuation rates due to pregnancy were 0.8 and 9.5, respectively. Sub-analysis showed higher expulsion rates for postabortal than interval insertions (levonorgestrel: 2.8 versus 6.8; Nova T: 3.0 versus 8.3).Seven trials examined immediate insertion. From meta-analysis of two multicenter trials, pregnancy was less likely for the TCu 220C versus the Lippes Loop (RR 0.38; 95% CI 0.20 to 0.72) as was expulsion (RR 0.51; 95% CI 0.30 to 0.88). Estimates for the TCu 220 versus the Copper 7 were 0.52 (95% CI 0.36 to 0.77) and 0.58 (95% CI 0.39 to 0.87), respectively. In other work, adding copper sleeves to the Lippes Loop improved efficacy (RR 3.82; 95% CI 1.41 to 10.36) and reduced expulsion (RR 3.37; 95% CI 1.65 to 6.90). AUTHORS' CONCLUSIONS: Insertion of an IUD immediately after abortion is safe and practical. IUD expulsion rates appear higher than after interval insertions. However, IUD use is higher at six months with immediate than with interval insertion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cochrane Handbook for Systematic Reviews of Interventions: Cochrane Book Series
(2008) · doi:10.1002/9780470712184 · Cited by 25,048
Intrauterine device insertion during the postpartum period: a systematic review
Kapp, N., & Curtis, K. M. (2009) · Contraception · doi:10.1016/j.contraception.2009.03.024 · Cited by 278
Eroğlu, K., Akkuzu, G., Vural, G., Dilbaz, B., Akın, A., Taşkın, L., & Haberal, A. (2006) · Contraception · doi:10.1016/j.contraception.2006.07.003 · Cited by 146
Long-term reversible contraception Twelve years of experience with the TCu380A and TCu220C
UNITEDNATIONSDEVELOPMENTPROGRAM, UNITEDNATIONSPOPULATIONFUND, & WORLDBANKSPECIALPROGRAMMEOFR (1997) · Contraception · doi:10.1016/s0010-7824(97)00186-8 · Cited by 129
Müller, A. L. L., Ramos, J. G. L., Costa, S. H. D. A. M., Dias, R. S., Valério, E. G., Hammes, L. S., Glitz, C. L., Zucatto, Â. E., Vettori, D. V., & Magalhães, J. A. A. (2005) · Contraception · doi:10.1016/j.contraception.2005.03.014 · Cited by 70
Fertility regulation in nursing women
Dı́az, S., Zepeda, A., Maturana, X., Reyes, M. V., Miranda, P. Y., Casado, M. E., Peralta, O., & Croxatto, H. B. (1997) · Contraception · doi:10.1016/s0010-7824(97)00135-2 · Cited by 68
Tatum, H. J., Beltran, R. S., Ramos, R. A., Kets, H. V., Sivin, I., & Schmidt, F. H. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)70033-9 · Cited by 56
Immediate postplacental IUD insertion: The expulsion problem
Thiéry, M., Kets, H. V., & Pas, H. V. D. (1985) · Contraception · doi:10.1016/0010-7824(85)90002-2 · Cited by 53
Clinical outcomes of two early postpartum IUD insertion programs in Africa
MORRISON, C. S., Waszak, C., Katz, K. R., Diabaté, F., & Mate, E. (1996) · Contraception · doi:10.1016/0010-7824(95)00254-5 · Cited by 52
Xu, J.-X., Rivera, R., Dunson, T. R., Zhuang, L., Yang, X., Ma, G.-T., & Chi, I. (1996) · Contraception · doi:10.1016/0010-7824(96)00117-5 · Cited by 50
Cited by
Ott, M. A., Sucato, G. S., COMMITTEE ON ADOLESCENCE, Braverman, P. K., Adelman, W. P., Alderman, E. M., Breuner, C. C., Levine, D. A., Marcell, A. V., & O’Brien, R. F. (2014) · PEDIATRICS · doi:10.1542/peds.2014-2300 · Cited by 402
COMMITTEE ON ADOLESCENCE, Braverman, P. K., Adelman, W. P., Alderman, E. M., FSHAM, Breuner, C. C., Levine, D. A., Marcell, A. V., & O’Brien, R. F. (2014) · Pediatrics · doi:10.1542/peds.2014-2299 · Cited by 355
Intrauterine device insertion during the postpartum period: a systematic review
Kapp, N., & Curtis, K. M. (2009) · Contraception · doi:10.1016/j.contraception.2009.03.024 · Cited by 278
No. 360-induced abortion: surgical abortion and second-trimester medical methods
Costescu, D., & Guilbert, É. (2018) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/j.jogc.2017.12.010 · Cited by 50
Mbizvo, M. T., Chou, D., & Shaw, D. (2013) · International Journal of Gynecology & Obstetrics · doi:10.1016/j.ijgo.2013.02.007 · Cited by 22
Metadata
- Authors
- Grimes, D. A., Lopez, L. M., Schulz, K. F., Van Vliet, H. A., & Stanwood, N. L.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- John Wiley & Sons, Ltd
- Published
- 2010-05-12
- Issue
- 5
- Pages
- CD001777-CD001777
- ISSN
- 1361-6137 (ISSN-L)
- OpenAlex
- W1929937915
- Cited by
- 321
- References
- 18
- Type
- reference entry
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Immediate post-partum insertion of intrauterine devices. https://app.cochat.ai/papers/10.1002/14651858.cd003036.pub2
- The paper
- Grimes, D. A., Lopez, L. M., Schulz, K. F., Van Vliet, H. A., & Stanwood, N. L. (2010). Immediate post-partum insertion of intrauterine devices. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd003036.pub2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.