The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Amniocentesis and chorionic villus sampling for prenatal diagnosis
Open accessAbstract
BACKGROUND: During pregnancy, fetal cells suitable for genetic testing can be obtained from amniotic fluid by amniocentesis (AC), placental tissue by chorionic villus sampling (CVS), or fetal blood. A major disadvantage of second trimester amniocentesis is that the results are available relatively late in pregnancy (after 16 weeks' gestation). Earlier alternatives are chorionic villus sampling (CVS) and early amniocentesis, which can be performed in the first trimester of pregnancy. OBJECTIVES: The objective of this review was to compare the safety and accuracy of all types of AC (i.e. early and late) and CVS (e.g. transabdominal, transcervical) for prenatal diagnosis. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (3 March 2017), ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP; 3 March 2017), and reference lists of retrieved studies. SELECTION CRITERIA: All randomised trials comparing AC and CVS by either transabdominal or transcervical route. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. The quality of the evidence was assessed using the GRADE approach. MAIN RESULTS: We included a total of 16 randomised studies, with a total of 33,555 women, 14 of which were deemed to be at low risk of bias. The number of women included in the trials ranged from 223 to 4606.Studies were categorized into six comparisons: 1. second trimester AC versus control; 2. early versus second trimester AC; 3. CVS versus second trimester AC; 4. CVS methods; 5. Early AC versus CVS; and 6. AC with or without ultrasound.One study compared second trimester AC with no AC (control) in a low risk population (women = 4606). Background pregnancy loss was around 2%. Second trimester AC compared to no testing increased total pregnancy loss by another 1%. The confidence intervals (CI) around this excess risk were relatively large (3.2% versus 2.3 %, average risk ratio (RR) 1.41, 95% CI 0.99 to 2.00; moderate-quality evidence). In the same study, spontaneous miscarriages were also higher (2.1% versus 1.3%; average RR 1.60, 95% CI 1.02 to 2.52; high-quality evidence). The number of congenital anomalies was similar in both groups (2.0% versus 2.2%, average RR 0.93, 95% CI 0.62 to 1.39; moderate-quality evidence).One study (women = 4334) found that early amniocentesis was not a safe early alternative compared to second trimester amniocentesis because of increased total pregnancy losses (7.6% versus 5.9%; average RR 1.29, 95% CI 1.03 to 1.61; high-quality evidence), spontaneous miscarriages (3.6% versus 2.5%, average RR 1.41, 95% CI 1.00 to 1.98; moderate-quality evidence), and a higher incidence of congential anomalies, including talipes (4.7% versus 2.7%; average RR 1.73, 95% CI 1.26 to 2.38; high-quality evidence).When pregnancy loss after CVS was compared with second trimester AC, there was a clinically significant heterogeneity in the size and direction of the effect depending on the technique used (transabdominal or transcervical), therefore, the results were not pooled. Only one study compared transabdominal CVS with second trimester AC (women = 2234). They found no clear difference between the two procedures in the total pregnancy loss (6.3% versus 7%; average RR 0.90, 95% CI 0.66 to 1.23, low-quality evidence), spontaneous miscarriages (3.0% versus 3.9%; average RR 0.77, 95% CI 0.49 to 1.21; low-quality evidence), and perinatal deaths (0.7% versus 0.6%; average RR 1.18, 95% CI 0.40 to 3.51; low-quality evidence). Transcervical CVS may carry a higher risk of pregnancy loss (14.5% versus 11.5%; average RR 1.40, 95% CI 1.09 to 1.81), but the results were quite heterogeneous.Five studies compared transabdominal and transcervical CVS (women = 7978). There were no clear differences between the two methods in pregnancy losses (average RR 1.16, 95% CI 0.81 to 1.65; very low-quality evidence), spontaneous miscarriages (average RR 1.68, 95% CI 0.79 to 3.58; very low-quality evidence), or anomalies (average RR 0.68, 95% CI 0.41 to 1.12; low-quality evidence). We downgraded the quality of the evidence to low due to heterogeneity between studies. Transcervical CVS may be more technically demanding than transabdominal CVS, with more failures to obtain sample (2.0% versus 1.1%; average RR 1.79, 95% CI 1.13 to 2.82, moderate-quality evidence).Overall, we found low-quality evidence for outcomes when early amniocentesis was compared to transabdominal CVS. Spontaneous miscarriage was the only outcome supported by moderate-quality evidence, resulting in more miscarriages after early AC compared with transabdominal CVS (2.3% versus 1.3%; average RR 1.73, 95% CI 1.15 to 2.60). There were no clear differences in pregnancy losses (average RR 1.15, 95% CI 0.86 to 1.54; low-quality evidence), or anomalies (average RR 1.14, 95% CI 0.57 to 2.30; very low-quality evidence).We found one
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
TOXIC-SHOCK SYNDROME NOT ASSOCIATED WITH MENSTRUATION
Reingold, A., Shands, K., Dan, B., & Broome, C. (1982) · The Lancet · doi:10.1016/s0140-6736(82)92552-1 · Cited by 1,164
Published by John Wiley & Sons Ltd
Modarresi, O. A. F., & Shakibaie, M. M. M. R. (2015) · Cited by 1,111
RANDOMISED CONTROLLED TRIAL OF GENETIC AMNIOCENTESIS IN 4606 LOW-RISK WOMEN
Tabor, A., Madsen, M., Obel, E., Philip, J., Bang, J., & Gaard-Pedersen, B. (1986) · The Lancet · doi:10.1016/s0140-6736(86)91218-3 · Cited by 869
Akolekar, R., Beta, J., Picciarelli, G., Ogilvie, C., & D'Antonio, F. (2015) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.14636 · Cited by 711
Procedure-Related Complications of Amniocentesis and Chorionic Villous Sampling: A Systematic Review
Mujezinovic, F., & Alfirevic, Z. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000278820.54029.e3 · Cited by 446
Self-citationWalton, J. (1972) · The Lancet · doi:10.1016/s0140-6736(72)91007-0 · Cited by 351
Randomised trial to assess safety and fetal outcome of early and midtrimester amniocentesis
(1998) · The Lancet · doi:10.1016/s0140-6736(97)12346-7 · Cited by 318
Nicolaides, K., Brizot, M., Patel, F., & Snijders, R. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91769-8 · Cited by 271
A Randomized Comparison of Transcervical and Transabdominal Chorionic-Villus Sampling
Jackson, L. G., Zachary, J. M., Fowler, S. E., Desnick, R. J., Golbus, M. S., Ledbetter, D. H., Mahoney, M. J., Pergament, E., Simpson, J. L., Black, S., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199208273270903 · Cited by 271
Amniocentesis and chorionic villus sampling for prenatal diagnosis
Alfirevic, Z., Mujezinovic, F., & Sundberg, K. (2003) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003252 · Cited by 247
Self-citationThe cost-effectiveness of screening for oral cancer in primary care
Speight, P., Palmer, S., Moles, D., Downer, M., Smith, D., Henriksson, M., & Augustovski, F. (2006) · Health Technology Assessment · doi:10.3310/hta10140 · Cited by 210
Smidt-Jensen, S., Philip, J., Lundsteen, C., Permin, M., Zachary, J. M., & Fowler, S. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)92946-d · Cited by 189
Sundberg, K., Bang, J., Smidt-Jensen, S., Brocks, V, Lundsteen, C., Parner, J., Keiding, N., & Philip, J. (1997) · The Lancet · doi:10.1016/s0140-6736(97)02449-5 · Cited by 188
MALIGNANT MELANOMA AND EXPOSURE TO FLUORESCENT LIGHTING AT WORK
Stern, R., Beral, V., & Evans, S. (1982) · The Lancet · doi:10.1016/s0140-6736(82)91257-0 · Cited by 185
Limb defects and chorionic villus sampling: results from an international registry, 1992-94
Froster, U., & Jackson, L. (1996) · The Lancet · doi:10.1016/s0140-6736(96)91136-8 · Cited by 142
Prostacyclin-stabilising-factor deficiency in thrombotic thrombocytopenic purpura.
Mikhailidis, D. P., & Dandona, P. (1982) · PubMed · Cited by 126
Late First-Trimester Invasive Prenatal Diagnosis: Results of an International Randomized Trial
Philip, J., Silver, R. K., Wilson, R. D., Thom, E. A., Zachary, J. M., Mohide, P., Mahoney, M. J., Simpson, J. L., Platt, L. D., Pergament, E., et al. (2004) · Obstetrics and Gynecology · doi:10.1097/01.aog.0000128049.73556.fb · Cited by 105
Johnson, J.-A. M., Wilson, D., Winsor, E. J. T., Singer, J., Dansereau, J., & Kalousek, D. K. (2009) · Fetal Diagnosis and Therapy · doi:10.1159/000264285 · Cited by 55
Club foot, an adverse outcome of early amniocentesis: disruption or deformation?
Farrell, S. A., Summers, A. M., Dallaire, L., Singer, J., Johnson, J.-A., & Wilson, R. D. (1999) · Journal of Medical Genetics · doi:10.1136/jmg.36.11.843 · Cited by 48
Emotional responses of pregnant women to chorionic villi sampling or amniocentesis
Spencer, J. W., & Cox, D. N. (1987) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(87)80281-8 · Cited by 43
Schoubroeck, D. V., & Verhaeghe, J. (2000) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2000.00240.x · Cited by 43
Anxiety reduction after chorionic villus sampling and genetic amniocentesis
Robinson, G. E., Garner, D. M., Olmsted, M. P., Shime, J., Hutton, E. M., & Crawford, B. (1988) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(88)80180-7 · Cited by 42
Nagel, H., Vandenbussche, F. P. H. A., Keirse, M. J. N. C., Oepkes, D., Oosterwijk, J. C., Beverstock, G. C., & Kanhai, H. H. H. (1998) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199805)18:5<465::aid-pd325>3.0.co;2-# · Cited by 37
Does local anesthesia decrease pain perception in women undergoing amniocentesis?
Gordon, M. C., Ventura-Braswell, A. M., Higby, K., & Ward, J. A. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2006.08.025 · Cited by 34
A randomised trial of progesterone prophylaxis after midtrimester amniocentesis
Corrado, F., Dugo, C., Cannata, M. L., Bartolo, M. D., Scilipoti, A., & Stella, N. C. (2002) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/s0301-2115(01)00418-3 · Cited by 32
Instruments for chorionic villus sampling for prenatal diagnosis
Young, C. B., von Dadelszen, P., & Alfirević, Ž. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000114.pub2 · Cited by 30
SHULMAN, L. P., Meyers, C. M., Simpson, J. L., et al. (1990) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(90)90013-w · Cited by 29
Hewison, J., Nixon, J., Fountain, J., Hawkins, K., Jones, C. R., Mason, G., Morley, S., & Thornton, J. (2007) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2007.01276.x · Cited by 28
Fischer, R. L., Bianculli, K. W., Sehdev, H. M., & Hediger, M. L. (2000) · The Journal of Maternal-Fetal Medicine · doi:10.1002/1520-6661(200009/10)9:5<294::aid-mfm8>3.0.co;2-3 · Cited by 24
Wilson, R. D., Johnson, J., Windrim, R. C., Dansereau, J., Singer, J., Winsor, E. J. T., & Kalousek, D. K. (2009) · Fetal Diagnosis and Therapy · doi:10.1159/000264440 · Cited by 20
Psychological reactions to pregnancy loss after prenatal diagnostic testing: Preliminary results
Robinson, G. E., Carr, M. L., Olmsted, M. P., & Wright, C. C. (1991) · Journal of Psychosomatic Obstetrics & Gynecology · doi:10.3109/01674829109078000 · Cited by 18
Incidence of fetal chromosome abnormalities in 2264 low‐risk women
Tabor, A., & Philip, J. (1987) · Prenatal Diagnosis · doi:10.1002/pd.1970070510 · Cited by 16
Cited by
Norton, M. E., Brar, H., Weiss, J., Karimi, A., Laurent, L. C., Caughey, A. B., Rodriguez, M. H., Williams, J., Mitchell, M. E., Adair, C. D., et al. (2012) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2012.05.021 · Cited by 596
Alldred, S. K., Takwoingi, Y., Guo, B., Pennant, M., Deeks, J. J., Neilson, J. P., & Alfirevic, Z. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd012599 · Cited by 529
Self-citationUpdate on Procedure-Related Risks for Prenatal Diagnosis Techniques
Tabor, A., & Alfirevic, Z. (2010) · Fetal Diagnosis and Therapy · doi:10.1159/000271995 · Cited by 399
Self-citationPlasma placental RNA allelic ratio permits noninvasive prenatal chromosomal aneuploidy detection
Lo, Y. M. D., Tsui, N. B. Y., Chiu, R. W. K., Lau, T. K., Leung, T. N., Heung, M. M. S., Gerovassili, A., Jin, Y., Nicolaides, K. H., Cantor, C. R., et al. (2007) · Nature Medicine · doi:10.1038/nm1530 · Cited by 379
Salomon, L. J., Sotiriadis, A., Wulff, C. B., Odibo, A., & Akolekar, R. (2019) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.20353 · Cited by 367
Metadata
- Authors
- Alfirevic, Z., Navaratnam, K., & Mujezinovic, F.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2017-09-04
- Volume
- 2017
- Issue
- 9
- Pages
- CD003252-CD003252
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1898907433
- Cited by
- 412
- References
- 33
- FWCI
- 21.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.