The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Pulmonary artery catheters for adult patients in intensive care
Open accessAbstract
BACKGROUND: Since pulmonary artery balloon flotation catheterization was first introduced in 1970, by HJ Swan and W Ganz, it has been widely disseminated as a diagnostic tool without rigorous evaluation of its clinical utility and effectiveness in critically ill patients. A pulmonary artery catheter (PAC) is inserted through a central venous access into the right side of the heart and floated into the pulmonary artery. PAC is used to measure stroke volume, cardiac output, mixed venous oxygen saturation and intracardiac pressures with a variety of additional calculated variables to guide diagnosis and treatment. Complications of the procedure are mainly related to line insertion. Relatively uncommon complications include cardiac arrhythmias, pulmonary haemorrhage and infarct, and associated mortality from balloon tip rupture. OBJECTIVES: To provide an up-to-date assessment of the effectiveness of a PAC on mortality, length of stay (LOS) in intensive care unit (ICU) and hospital and cost of care in adult intensive care patients. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2011, Issue 12); MEDLINE (1954 to January 2012); EMBASE (1980 to January 2012); CINAHL (1982 to January 2012), and reference lists of articles. We contacted researchers in the field. We did a grey literature search for articles published until January 2012. SELECTION CRITERIA: We included all randomized controlled trials conducted in adults ICUs, comparing management with and without a PAC. DATA COLLECTION AND ANALYSIS: We screened the titles and abstracts and then the full text reports identified from our electronic search. Two authors (SR and MG) independently reviewed the titles, abstracts and then the full text reports for inclusion. We determined the final list of included studies by discussion among the group members (SR, ND, MG, AK and SC) with consensus agreement. We included all the studies that were in the original review. We assessed seven domains of potential risk of bias for the included studies. We examined the clinical, methodological and statistical heterogeneity and used random-effects model for meta-analysis. We calculated risk ratio for mortality across studies and mean days for LOS. MAIN RESULTS: We included 13 studies (5686 patients). We judged blinding of participants and personnel and blinding of outcome assessment to be at high risk in about 50% of the included studies and at low risk in 25% to 30% of the studies. Regardless of the high risk of performance bias these studies were included based on the low weight the studies had in the meta-analysis. We rated 75% of the studies as low risk for selection, attrition and reporting bias. All 13 studies reported some type of hospital mortality (28-day, 30-day, 60-day or ICU mortality). We considered studies of high-risk surgery patients (eight studies) and general intensive care patients (five studies) separately as subgroups for meta-analysis. The pooled risk ratio (RR) for mortality for the studies of general intensive care patients was 1.02 (95% confidence interval (CI) 0.96 to 1.09) and for the studies of high-risk surgery patients the RR was 0.98 (95% CI 0.74 to 1.29). Of the eight studies of high-risk surgery patients, five evaluated the effectiveness of pre-operative optimization but there was no difference in mortality when these studies were examined separately. PAC did not affect general ICU LOS (reported by four studies) or hospital LOS (reported by nine studies). Four studies, conducted in the United States (US), reported costs based on hospital charges billed, which on average were higher in the PAC groups. Two of these studies qualified for analysis and did not show a statistically significant hospital cost difference (mean difference USD 900, 95% CI -2620 to 4420, P = 0.62). AUTHORS' CONCLUSIONS: PAC is a diagnostic and haemodynamic monitoring tool but not a therapeutic intervention. Our review concluded that use of a PAC did not alter the mortality, general ICU or hospital LOS, or cost for adult patients in intensive care. The quality of evidence was high for mortality and LOS but low for cost analysis. Efficacy studies are needed to determine if there are optimal PAC-guided management protocols, which when applied to specific patient groups in ICUs could result in benefits such as shock reversal, improved organ function and less vasopressor use. Newer, less-invasive haemodynamic monitoring tools need to be validated against PAC prior to clinical use in critically ill patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cochrane Handbook for Systematic Reviews of Interventions: Cochrane Book Series
(2008) · doi:10.1002/9780470712184 · Cited by 25,048
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Cited by
Critical care and the global burden of critical illness in adults
Adhikari, N. K., Fowler, R. A., Bhagwanjee, S., & Rubenfeld, G. D. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60446-1 · Cited by 1,304
Harjola, V.-P., Mebazaa, A., Čelutkienė, J., Bettex, D., Bueno, H., Chioncel, O., Crespo-Leiro, M. G., Falk, V., Filippatos, G., Gibbs, S., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.478 · Cited by 720
Checketts, M. R., Alladi, R., Ferguson, K., Gemmell, L., Handy, J. M., Klein, A. A., Love, N. J., Misra, U., Morris, C., Nathanson, M. H., et al. (2016) · Anaesthesia · doi:10.1111/anae.13316 · Cited by 490
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Thompson, A., Fleischmann, K. E., Smilowitz, N. R., de las Fuentes, L., Mukherjee, D., Aggarwal, N. R., Ahmad, F. S., Allen, R. B., Altin, S. E., Auerbach, A., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001285 · Cited by 365
Metadata
- Authors
- Rajaram, S. S., Desai, N. K., Kalra, A., Gajera, M., Cavanaugh, S. K., Brampton, W., Young, D., Harvey, S., & Rowan, K.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2013-02-28
- Volume
- 2018
- Issue
- 12
- Pages
- CD003408-CD003408
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2002917494
- Cited by
- 446
- References
- 2
- FWCI
- 37.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulmonary artery catheters for adult patients in intensive care. https://app.cochat.ai/papers/10.1002/14651858.cd003408.pub3
- The paper
- Rajaram, S. S., Desai, N. K., Kalra, A., Gajera, M., Cavanaugh, S. K., Brampton, W., Young, D., Harvey, S., & Rowan, K. (2013). Pulmonary artery catheters for adult patients in intensive care. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd003408.pub3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.