Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Pre-operative autologous donation for minimising perioperative allogeneic blood transfusion

Open access
Henry, David A, Carless, Paul A, Moxey, Annette J, O'Connell, Dianne, Ker, Katharine, Fergusson, Dean A · 2001 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Public concerns regarding the safety of transfused blood have prompted re-consideration of the indications for the transfusion of allogeneic red cells (blood from an unrelated donor), and a range of techniques designed to minimise transfusion requirements. OBJECTIVES: To examine the evidence for the efficacy of pre-operative autologous blood donation (PAD) in reducing the need for peri-operative allogeneic red blood cell (RBC) transfusion. SEARCH STRATEGY: Articles were identified by: computer searches of OVID MEDLINE, EMBASE, and Current Contents (to March 2001) and web sites of international health technology assessment agencies (to January 2001). References in the identified trials were checked and authors contacted to identify additional studies. SELECTION CRITERIA: Randomised controlled trials with a concurrent control group in which adult patients, scheduled for non-urgent surgery, were randomised to PAD, or to a control group who did not receive the intervention. DATA COLLECTION AND ANALYSIS: Trial quality was assessed using criteria proposed by Schulz et al (1995) and Jadad et al (1996). The principle outcomes were: the number of patients exposed to allogeneic red blood cells, and the amount of blood transfused. Other clinical outcomes are detailed in the review. MAIN RESULTS: Overall PAD reduced the risk of receiving an allogeneic blood transfusion by a relative 63% (RR=0.37: 95%CI:0.26,0.54). The absolute reduction in risk of allogeneic transfusion was 43.8% (RD=-0.438: 95%CI: -0.607,-0.268). In contrast the results show that the risk of receiving any blood transfusion (allogeneic and/or autologous) is actually increased by pre-operative autologous blood donation (RR=1.29: 95%CI: 1.12,1.48). Trials were unblinded and allocation concealment was not described in 87.5% of the trials. REVIEWER'S CONCLUSIONS: Although the trials of PAD showed a reduction in the need for allogeneic blood the methodological quality of the trials was poor and the overall transfusion rates (allogeneic and/or autologous) in these trials were high, and were increased by recruitment into the PAD arms of the trials. This raises questions about the true benefit of PAD. In the absence of large, high quality trials using clinical endpoints, it is not possible to say whether the benefits of PAD outweigh the harms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd003602

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 181

Metadata

Authors
Henry, D. A., Carless, P. A., Moxey, A. J., O'Connell, D., Ker, K., & Fergusson, D. A.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2001-10-23
Volume
2010
Issue
4
Pages
CD003602-CD003602
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W1936462000
Cited by
181
References
1
FWCI
2.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pre-operative autologous donation for minimising perioperative allogeneic blood transfusion. https://app.cochat.ai/papers/10.1002/14651858.cd003602
The paper
Henry, D. A., Carless, P. A., Moxey, A. J., O'Connell, D., Ker, K., & Fergusson, D. A. (2001). Pre-operative autologous donation for minimising perioperative allogeneic blood transfusion. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd003602

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.