Methods of milk expression for lactating women
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Breastfeeding is important, however not all infants can feed at the breast and methods of expressing milk need evaluation. OBJECTIVES: To assess acceptability, effectiveness, safety, effect on milk composition, contamination and costs of methods of milk expression. SEARCH METHODS: We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (21 March 2016), handsearched relevant journals and conference proceedings, and contacted experts in the field to seek additional published or unpublished studies. We also examined reference lists of all relevant retrieved papers. SELECTION CRITERIA: Randomised and quasi-randomised trials comparing methods at any time after birth. DATA COLLECTION AND ANALYSIS: Three review authors independently assessed trials for inclusion and risk of bias, extracted data and checked them for accuracy. MAIN RESULTS: This updated review includes 41 trials involving 2293 participants, with 22 trials involving 1339 participants contributing data for analysis. Twenty-six of the trials referred to mothers of infants in neonatal units (n = 1547) and 14 to mothers of healthy infants at home (n = 730), with one trial containing mothers of both neonatal and healthy older infants (n = 16). Eleven trials compared one or more types of pump versus hand expression and 14 studies compared one type of pump versus another type of pump, with three of these studies comparing both hand expression and pump types. Twenty studies compared a specific protocol or adjunct behaviour including sequential versus simultaneous pumping protocols, pumping frequency, provision of an education and support intervention, relaxation, breast massage, combining hand expression with pumping and a breast cleansing protocol.Due to heterogeneity in participants, interventions, and outcomes measured or reported, we were unable to pool findings for most of the specified outcomes. It was not possible therefore to produce a 'Summary of findings' table in this update. Most of the included results were derived from single studies. Trials took place in 14 countries under a variety of circumstances and were published from 1982 to 2015. Sixteen of the 30 trials that evaluated pumps or products had support from the manufacturers. The risk of bias of the included studies was variable. Primary outcomesOnly one of the 17 studies examining maternal satisfaction/acceptability with the method or adjunct behaviour provided data suitable for analysis. In this study, self-efficacy was assessed by asking mothers if they agreed or disagreed with the following statement: 'I don't want anyone to see me (hand expressing/pumping)'. The study found that mothers who were using the electric pump were more likely to agree with the statement compared to mothers hand expressing, (mean difference (MD) 0.70, 95% confidence interval (CI) 0.15 to 1.25; P = 0.01, participants = 68). Mothers who were hand expressing reported that the instructions for expression were clearer compared to the electric pump, (MD -0.40, 95% CI -0.75 to -0.05; P = 0.02, participants = 68). Descriptive reporting of satisfaction in the other studies varied in the measures used, did not indicate a clear preference for one pump type, although there was satisfaction with some relaxation and support interventions.We found no clinically significant differences between methods related to contamination of the milk that compared any type of pump to hand expression (risk ratio (RR) 1.13, 95% CI 0.79 to 1.61; P = 0.51, participants = 28), manual pump compared to hand expression, (MD 0.20, 95% CI -0.18 to 0.58; P = 0.30, participants = 142) a large electric pump compared to hand expression (MD 0.10, 95% CI -0.29 to 0.49; P = 0.61, participants = 123), or a large electric pump compared to a manual pump (MD -0.10, 95% CI -0.46 to 0.26; P = 0.59, participants = 141).The level of maternal breast or nipple pain or damage was similar in comparisons of a large electric pump to hand expression (MD 0.02, 95% CI -0.67 to 0.71; P = 0.96, participants = 68). A study comparing a manual and large electric pump, reported sore nipples in 7% for both groups and engorgement in 4% using a manual pump versus 6% using an electric pump; and in one study no nipple damage was reported in the hand-expression group, and one case of nipple damage in each of the manual pump and the large electric pump groups.One study examined adverse effects on infants, however as the infants did not all receive their mothers' expressed milk, we have not included the results. Secondary outcomesThe quantity of expressed milk obtained was increased, in some studies by a clinically significant amount, in interventions involving relaxation, music, warmth, massage, initiation of pumping, increased frequency of pumping and suitable breast shield size. Support programmes and simultaneous compared to sequential pumping did not show a difference in milk obtained. No pump consistently increased the milk volume obtained significan
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breastfeeding and the use of human milk
BREASTFEEDING, S. O., Eidelman, A. I., Schanler, R. J., Johnston, M., Landers, S., Noble, L., Szucs, K., & Viehmann, L. (2012) · Pediatrics · doi:10.1542/peds.2011-3552 · Cited by 4,357
Meta-analyses involving cross-over trials: methodological issues
Elbourne, D. R., Altman, D. G., Higgins, J. P., Curtin, F., Worthington, H. V., & Vail, A. (2002) · International Journal of Epidemiology · doi:10.1093/ije/31.1.140 · Cited by 2,305
Deeks, J. J., Altman, D. G., & Bradburn, M. J. (2001) · Systematic Reviews in Health Care · doi:10.1002/9780470693926.ch15 · Cited by 2,163
Breastfeeding and Child Cognitive Development: New Evidence From a Large Randomized Trial
Kramer, M. S. (2008) · Archives of General Psychiatry · doi:10.1001/archpsyc.65.5.578 · Cited by 1,016
Prolonged and Exclusive Breastfeeding Reduces the Risk of Infectious Diseases in Infancy
Duijts, L., Jaddoe, V. W. V., Hofman, A., & Moll, H. A. (2010) · Pediatrics · doi:10.1542/peds.2008-3256 · Cited by 682
Breastfeeding and incidence of non-insulin-dependent diabetes mellitus in Pima Indians
Pettitt, D. J., Forman, M. R., Hanson, R. L., Knowler, W. C., & Bennett, P. H. (1997) · The Lancet · doi:10.1016/s0140-6736(96)12103-6 · Cited by 357
Cited by
Embleton, N. D., Jennifer Moltu, S., Lapillonne, A., van den Akker, C. H. P., Carnielli, V., Fusch, C., Gerasimidis, K., van Goudoever, J. B., Haiden, N., Iacobelli, S., et al. (2023) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/mpg.0000000000003642 · Cited by 472
Arslanoglu, S., Bertino, E., Tonetto, P., De Nisi, G., Ambruzzi, A. M., Biasini, A., Profeti, C., Spreghini, M. R., & Moro, G. E. (2010) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2010.512414 · Cited by 320
Promoting Human Milk and Breastfeeding for the Very Low Birth Weight Infant
Parker, M. G., Stellwagen, L. M., Noble, L., Kim, J. H., Poindexter, B. B., Puopolo, K. M., & SECTION ON BREASTFEEDING, C. O. N. (2021) · Pediatrics · doi:10.1542/peds.2021-054272 · Cited by 265
Optimizing Nutrition in Preterm Low Birth Weight Infants—Consensus Summary
Kumar, R. K., Singhal, A., Vaidya, U., Banerjee, S., Anwar, F., & Rao, S. (2017) · Frontiers in Nutrition · doi:10.3389/fnut.2017.00020 · Cited by 237
Metadata
- Authors
- Becker, G. E., Smith, H. A., & Cooney, F.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2016-09-29
- Volume
- 2016
- Issue
- 9
- Pages
- CD006170-CD006170
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1493231727
- Cited by
- 181
- References
- 6
- FWCI
- 11.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.