The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Interventions to prevent occupational noise-induced hearing loss
Open accessAbstract
BACKGROUND: This is the second update of a Cochrane Review originally published in 2009. Millions of workers worldwide are exposed to noise levels that increase their risk of hearing disorders. There is uncertainty about the effectiveness of hearing loss prevention interventions. OBJECTIVES: To assess the effectiveness of non-pharmaceutical interventions for preventing occupational noise exposure or occupational hearing loss compared to no intervention or alternative interventions. SEARCH METHODS: We searched the CENTRAL; PubMed; Embase; CINAHL; Web of Science; BIOSIS Previews; Cambridge Scientific Abstracts; and OSH UPDATE to 3 October 2016. SELECTION CRITERIA: We included randomised controlled trials (RCT), controlled before-after studies (CBA) and interrupted time-series (ITS) of non-clinical interventions under field conditions among workers to prevent or reduce noise exposure and hearing loss. We also collected uncontrolled case studies of engineering controls about the effect on noise exposure. DATA COLLECTION AND ANALYSIS: Two authors independently assessed study eligibility and risk of bias and extracted data. We categorised interventions as engineering controls, administrative controls, personal hearing protection devices, and hearing surveillance. MAIN RESULTS: We included 29 studies. One study evaluated legislation to reduce noise exposure in a 12-year time-series analysis but there were no controlled studies on engineering controls for noise exposure. Eleven studies with 3725 participants evaluated effects of personal hearing protection devices and 17 studies with 84,028 participants evaluated effects of hearing loss prevention programmes (HLPPs). Effects on noise exposure Engineering interventions following legislationOne ITS study found that new legislation in the mining industry reduced the median personal noise exposure dose in underground coal mining by 27.7 percentage points (95% confidence interval (CI) -36.1 to -19.3 percentage points) immediately after the implementation of stricter legislation. This roughly translates to a 4.5 dB(A) decrease in noise level. The intervention was associated with a favourable but statistically non-significant downward trend in time of the noise dose of -2.1 percentage points per year (95% CI -4.9 to 0.7, 4 year follow-up, very low-quality evidence). Engineering intervention case studiesWe found 12 studies that described 107 uncontrolled case studies of immediate reductions in noise levels of machinery ranging from 11.1 to 19.7 dB(A) as a result of purchasing new equipment, segregating noise sources or installing panels or curtains around sources. However, the studies lacked long-term follow-up and dose measurements of workers, and we did not use these studies for our conclusions. Hearing protection devicesIn general hearing protection devices reduced noise exposure on average by about 20 dB(A) in one RCT and three CBAs (57 participants, low-quality evidence). Two RCTs showed that, with instructions for insertion, the attenuation of noise by earplugs was 8.59 dB better (95% CI 6.92 dB to 10.25 dB) compared to no instruction (2 RCTs, 140 participants, moderate-quality evidence). Administrative controls: information and noise exposure feedbackOn-site training sessions did not have an effect on personal noise-exposure levels compared to information only in one cluster-RCT after four months' follow-up (mean difference (MD) 0.14 dB; 95% CI -2.66 to 2.38). Another arm of the same study found that personal noise exposure information had no effect on noise levels (MD 0.30 dB(A), 95% CI -2.31 to 2.91) compared to no such information (176 participants, low-quality evidence). Effects on hearing loss Hearing protection devicesIn two studies the authors compared the effect of different devices on temporary threshold shifts at short-term follow-up but reported insufficient data for analysis. In two CBA studies the authors found no difference in hearing loss from noise exposure above 89 dB(A) between muffs and earplugs at long-term follow-up (OR 0.8, 95% CI 0.63 to 1.03 ), very low-quality evidence). Authors of another CBA study found that wearing hearing protection more often resulted in less hearing loss at very long-term follow-up (very low-quality evidence). Combination of interventions: hearing loss prevention programmesOne cluster-RCT found no difference in hearing loss at three- or 16-year follow-up between an intensive HLPP for agricultural students and audiometry only. One CBA study found no reduction of the rate of hearing loss (MD -0.82 dB per year (95% CI -1.86 to 0.22) for a HLPP that provided regular personal noise exposure information compared to a programme without this information.There was very-low-quality evidence in four very long-term studies, that better use of hearing protection devices as part of a HLPP decreased the risk of hearing loss compared to less well used hearing protection in HLPPs (OR 0.40, 95% CI 0.23 to 0.69). Other aspects of the HLP
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Updated Method Guidelines for Systematic Reviews in the Cochrane Collaboration Back Review Group
van Tulder, M., Furlan, A., Bombardier, C., & Bouter, L. (2003) · Spine · doi:10.1097/01.brs.0000065484.95996.af · Cited by 2,180
Reporting of Noninferiority and Equivalence Randomized Trials: An Extension of the CONSORT Statement
Piaggio, G., Elbourne, D. R., Altman, D. G., Pocock, S. J., Evans, S. J. W., & CONSORT Group, F. T. (2006) · JAMA · doi:10.1001/jama.295.10.1152 · Cited by 1,153
Cited by
Auditory and non-auditory effects of noise on health
Basner, M., Babisch, W., Davis, A., Brink, M., Clark, C., Janssen, S., & Stansfeld, S. (2014) · The Lancet · doi:10.1016/s0140-6736(13)61613-x · Cited by 2,473
Morgan, R. L., Whaley, P., Thayer, K. A., & Schünemann, H. J. (2018) · Environment International · doi:10.1016/j.envint.2018.07.015 · Cited by 1,282
Le, T. N., Straatman, L. V., Lea, J., & Westerberg, B. (2017) · Journal of Otolaryngology - Head & Neck Surgery · doi:10.1186/s40463-017-0219-x · Cited by 465
GRADE: Assessing the quality of evidence in environmental and occupational health
Morgan, R. L., Thayer, K. A., Bero, L., Bruce, N., Falck-Ytter, Y., Ghersi, D., Guyatt, G., Hooijmans, C., Langendam, M., Mandrioli, D., et al. (2016) · Environment International · doi:10.1016/j.envint.2016.01.004 · Cited by 277
Self-citationNatarajan, N., Batts, S., & Stankovic, K. M. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12062347 · Cited by 254
Metadata
- Authors
- Tikka, C., Verbeek, J. H., Kateman, E., Morata, T. C., Dreschler, W. A., & Ferrite, S.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2017-07-07
- Volume
- 2019
- Issue
- 1
- Pages
- CD006396-CD006396
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2124534928
- Cited by
- 214
- References
- 3
- FWCI
- 22.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interventions to prevent occupational noise-induced hearing loss. https://app.cochat.ai/papers/10.1002/14651858.cd006396.pub4
- The paper
- Tikka, C., Verbeek, J. H., Kateman, E., Morata, T. C., Dreschler, W. A., & Ferrite, S. (2017). Interventions to prevent occupational noise-induced hearing loss. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd006396.pub4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.