Low pressure versus standard pressure pneumoperitoneum in laparoscopic cholecystectomy
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND: A pneumoperitoneum of 12 to 16 mm Hg is used for laparoscopic cholecystectomy. Lower pressures are claimed to be safe and effective in decreasing cardiopulmonary complications and pain. OBJECTIVES: To assess the benefits and harms of low pressure pneumoperitoneum compared with standard pressure pneumoperitoneum in people undergoing laparoscopic cholecystectomy. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) in The Cochrane Library, MEDLINE, EMBASE, and Science Citation Index Expanded until February 2013 to identify randomised trials,using search strategies. SELECTION CRITERIA: We considered only randomised clinical trials, irrespective of language, blinding, or publication status for inclusion in the review. DATA COLLECTION AND ANALYSIS: Two review authors independently identified trials and independently extracted data. We calculated the risk ratio (RR), mean difference (MD), or standardised mean difference (SMD) with 95% confidence intervals (CI) using both fixed-effect and random-effects models with RevMan 5 based on available case analysis. MAIN RESULTS: A total of 1092 participants randomly assigned to the low pressure group (509 participants) and the standard pressure group (583 participants) in 21 trials provided information for this review on one or more outcomes. Three additional trials comparing low pressure pneumoperitoneum with standard pressure pneumoperitoneum (including 179 participants) provided no information for this review. Most of the trials included low anaesthetic risk participants undergoing elective laparoscopic cholecystectomy. One trial including 140 participants was at low risk of bias. The remaining 20 trials were at high risk of bias. The overall quality of evidence was low or very low. No mortality was reported in either the low pressure group (0/199; 0%) or the standard pressure group (0/235; 0%) in eight trials that reported mortality. One participant experienced the outcome of serious adverse events (low pressure group 1/179, 0.6%; standard pressure group 0/215, 0%; seven trials; 394 participants; RR 3.00; 95% CI 0.14 to 65.90; very low quality evidence). Quality of life, return to normal activity, and return to work were not reported in any of the trials. The difference between groups in the conversion to open cholecystectomy was imprecise (low pressure group 2/269, adjusted proportion 0.8%; standard pressure group 2/287, 0.7%; 10 trials; 556 participants; RR 1.18; 95% CI 0.29 to 4.72; very low quality evidence) and was compatible with an increase, a decrease, or no difference in the proportion of conversion to open cholecystectomy due to low pressure pneumoperitoneum. No difference in the length of hospital stay was reported between the groups (five trials; 415 participants; MD -0.30 days; 95% CI -0.63 to 0.02; low quality evidence). Operating time was about two minutes longer in the low pressure group than in the standard pressure group (19 trials; 990 participants; MD 1.51 minutes; 95% CI 0.07 to 2.94; very low quality evidence). AUTHORS' CONCLUSIONS: Laparoscopic cholecystectomy can be completed successfully using low pressure in approximately 90% of people undergoing laparoscopic cholecystectomy. However, no evidence is currently available to support the use of low pressure pneumoperitoneum in low anaesthetic risk patients undergoing elective laparoscopic cholecystectomy. The safety of low pressure pneumoperitoneum has to be established. Further well-designed trials are necessary, particularly in people with cardiopulmonary disorders who undergo laparoscopic cholecystectomy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634
Moher, D., Pham, B., Jones, A., Cook, D. J., Jadad, A. R., Moher, M., Tugwell, P., & Klassen, T. P. (1998) · The Lancet · doi:10.1016/s0140-6736(98)01085-x · Cited by 3,560
Wood, L., Egger, M., Gluud, L. L., Schulz, K. F., Jüni, P., Altman, D. G., Gluud, C., Martin, R. M., Wood, A. J. G., & Sterne, J. A. C. (2008) · BMJ · doi:10.1136/bmj.39465.451748.ad · Cited by 2,538
Trial sequential analysis may establish when firm evidence is reached in cumulative meta-analysis
Wetterslev, J., Thorlund, K., Brok, J., & Gluud, C. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.03.013 · Cited by 1,881
Industry sponsorship and research outcome
Lundh, A., Lexchin, J., Mintzes, B., Schroll, J. B., & Bero, L. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.mr000033.pub3 · Cited by 1,697
A comparison of methods to detect publication bias in meta‐analysis
Macaskill, P., Walter, S. D., & Irwig, L. (2001) · Statistics in Medicine · doi:10.1002/sim.698 · Cited by 1,286
Savović, J., Jones, H. E., Altman, D. G., Harris, R. J., Jüni, P., Pildal, J., Als-Nielsen, B., Balk, E. M., Gluud, C., Gluud, L. L., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-6-201209180-00537 · Cited by 1,049
Intention-to-Treat Analysis: Implications for Quantitative and Qualitative Research
NEWELL, D. J. (1992) · International Journal of Epidemiology · doi:10.1093/ije/21.5.837 · Cited by 715
Royle, P., & Milne, R. (2003) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462303000552 · Cited by 693
Savović, J., Jones, H., Altman, D., Harris, R., Jűni, P., Pildal, J., Als-Nielsen, B., Balk, E., Gluud, C., Gluud, L., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16350 · Cited by 668
Cited by
What is the evidence for the use of low-pressure pneumoperitoneum? A systematic review
Özdemir-van Brunschot, D. M. D., van Laarhoven, K. C. J. H. M., Scheffer, G.-J., Pouwels, S., Wever, K. E., & Warlé, M. C. (2016) · Surgical Endoscopy · doi:10.1007/s00464-015-4454-9 · Cited by 166
“With regard to serious adverse events and conversion to open procedure, no significant differences could be demonstrated for laparoscopic cholecystectomy [53, 73].”
BackgroundPessia, B., Schietroma, M., Colozzi, S., Carlei, F., Di Furia, M., & Amicucci, G. (2018) · Journal of Minimal Access Surgery · doi:10.4103/jmas.jmas_120_16 · Cited by 6
“The effects of low‑ and high‑intra‑abdominal pressures and different anaesthetic agents on immune response have been studied previously, [38,39] but regarding the use of supplemental oxygen in LNF and inflammatory and immune response, there is no information in the literature.”
Metadata
- Authors
- Gurusamy, K. S., Vaughan, J., & Davidson, B. R.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2014-03-18
- Volume
- 2014
- Issue
- 3
- Pages
- CD006930-CD006930
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1591050026
- Cited by
- 228
- References
- 12
- FWCI
- 22.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.