CoChat

Blood pressure lowering efficacy of nonselective beta-blockers for primary hypertension

Open access
Wong, Gavin WK, Wright, James M · 2014 · Cochrane Database of Systematic Reviews
Cited by 61

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Beta-blockers are one of the classes of drugs frequently used to treat hypertension. Quantifying the blood pressure (BP) lowering effects of nonselective beta-blockers provides important information that aids clinical decision making. OBJECTIVES: To quantify the dose-related effects of nonselective beta-adrenergic receptor blockers (beta-blockers) on systolic blood pressure (SBP) and diastolic blood pressure (DBP) as compared with placebo in people with primary hypertension. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and ClinicalTrials.gov for randomized controlled trials up to October 2013. SELECTION CRITERIA: Randomized, double-blind, placebo-controlled, parallel or cross-over trials. Studies had to contain a nonselective beta-blocker monotherapy arm with a fixed dose. Participants enrolled into the studies had to have primary hypertension at baseline. Duration of studies had to be between three and 12 weeks. DATA COLLECTION AND ANALYSIS: Two review authors (GW and AL) independently confirmed the inclusion of studies and extracted the data. MAIN RESULTS: We included 25 RCTs that evaluated the BP lowering effects of seven nonselective beta-blockers in 1264 people with hypertension. Among the 25 RCTs, four were parallel studies and 21 were cross-over studies. Overall, nonselective beta-blockers lowered systolic BP and diastolic BP compared with placebo. Nonselective beta-blockers, in the recommended dose range, did not showed a convincing dose-response relationship by direct comparison. The once (1x) and twice (2x) starting dose subgroups contained the largest sample size. The estimate of BP lowering efficacy for nonselective beta-blockers by combining the 1x and 2x starting dose subgroup was -10 mmHg (95% CI -11 to -8) for systolic BP and -7 mmHg (95% CI -8 to -6) for diastolic BP (low-quality evidence). Nonselective beta-blockers starting at the 1x recommended starting doses lowered heart rate by 12 beats per minute (95% CI 10 to 13) (low-quality evidence). The dose-response relationship in heart rate was evident by both direct and indirect comparison. Due to imprecision, there was no clear evidence of an effect of nonselective beta-blockers on pulse pressure in any dose subgroups except for a small reduction with the 2x starting dose (-2.2 mmHg, 95% CI -3.7 to -0.7) (very low quality evidence). The point estimates in the 1x, four times (4x) and eight times (8x) starting dose subgroups were similar to the 2x starting dose subgroup. Therefore, it would appear that if nonselective beta-blockers do lower pulse pressure, the magnitude is likely to be about 2 mmHg. There were very limited data (two studies) on withdrawals due to adverse effects (risk ratio (RR) 0.84; 95% CI 0.38 to 1.82). AUTHORS' CONCLUSIONS: In people with mild-to-moderate hypertension, nonselective beta-blockers lowered peak BP by a mean of -10/-7 mmHg (systolic/diastolic) and reduced heart rate by 12 beats per minute. Propranolol and penbutolol were the two drugs that contributed to most of the data for nonselective beta-blockers. This estimate is likely exaggerated due to the presence of extreme outliers and other sources of bias. If we removed the extreme outliers from the analysis, the estimate for non-selective beta-blockers was lower (-8/-5 mmHg (systolic/diastolic)). Nonselective beta-blockers did not show a convincing graded dose-response in the recommended dose range for systolic BP and diastolic BP, while higher dose nonselective beta-blockers provided greater reduction of heart rate. Using higher dose nonselective beta-blockers might cause more side effects, such as bradycardia, without producing an additional BP lowering effect. The effect of nonselective beta-blockers on pulse pressure was likely small, at about 2 mmHg.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd007452.pub2

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 61

Metadata

Authors
Wong, G. W., & Wright, J. M.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2014-02-28
Volume
2014
Issue
2
Pages
CD007452-CD007452
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W4243909350
Cited by
61
References
2
FWCI
3.58
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.