Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 313

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Clinically-indicated replacement versus routine replacement of peripheral venous catheters

Open access
Webster, Joan, Osborne, Sonya, Rickard, Claire M, New, Karen·2013·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: US Centers for Disease Control guidelines recommend replacement of peripheral intravenous catheters (PIVC) no more frequently than every 72 to 96 hours. Routine replacement is thought to reduce the risk of phlebitis and bloodstream infection. Catheter insertion is an unpleasant experience for patients and replacement may be unnecessary if the catheter remains functional and there are no signs of inflammation or infection. Costs associated with routine replacement may be considerable. This is the third update of a review first published in 2010. OBJECTIVES: To assess the effects of removing peripheral intravenous catheters when clinically indicated compared with removing and re-siting the catheter routinely. SEARCH METHODS: The Cochrane Vascular Information Specialist searched the Cochrane Vascular Specialised Register, CENTRAL, MEDLINE, Embase and CINAHL and World Health Organization International Clinical Trials Registry Platform and ClinicalTrials.gov trials registers to 18 April 2018. We also undertook reference checking, and contacted researchers and manufacturers to identify additional studies. SELECTION CRITERIA: We included randomised controlled trials that compared routine removal of PIVC with removal only when clinically indicated, in hospitalised or community-dwelling patients receiving continuous or intermittent infusions. DATA COLLECTION AND ANALYSIS: Three review authors independently reviewed trials for inclusion, extracted data, and assessed risk of bias using Cochrane methods. We used GRADE to assess the overall evidence certainty. MAIN RESULTS: This update contains two new trials, taking the total to nine included studies with 7412 participants. Eight trials were conducted in acute hospitals and one in a community setting. We rated the overall certainty of evidence as moderate for most outcomes, due to serious risk of bias for unblinded outcome assessment or imprecision, or both. Because outcome assessment was unblinded in all of the trials, none met our criteria for high methodological quality.Primary outcomesSeven trials (7323 participants), assessed catheter-related bloodstream infection (CRBSI). There is no clear difference in the incidence of CRBSI between the clinically indicated (1/3590) and routine change (2/3733) groups (risk ratio (RR) 0.61, 95% confidence interval (CI) 0.08 to 4.68), low-certainty evidence (downgraded twice for serious imprecision).All trials reported incidence of thrombophlebitis and we combined the results from seven of these in the analysis (7323 participants). We excluded two studies in the meta-analysis because they contributed to high heterogeneity. There is no clear difference in the incidence of thrombophlebitis whether catheters were changed according to clinical indication or routinely (RR 1.07, 95% CI 0.93 to 1.25; clinically indicated 317/3590; 3-day change 307/3733, moderate-certainty evidence, downgraded once for serious risk of bias). The result was unaffected by whether the infusion was continuous or intermittent. Six trials provided thrombophlebitis rates by number of device days (32,709 device days). There is no clear difference between groups (RR 0.90, 95% CI 0.76 to 1.08; clinically indicated 248/17,251; 3-day change 236/15,458; moderate-certainty evidence, downgraded once for serious risk of bias).One trial (3283 participants), assessed all-cause blood stream infection (BSI). We found no clear difference in the all-cause BSI rate between the two groups (RR 0.47, 95% CI 0.15 to 1.53; clinically indicated: 4/1593 (0.02%); routine change 9/1690 (0.05%); moderate-certainty evidence, downgraded one level for serious imprecision).Three trials (4244 participants), investigated costs; clinically indicated removal probably reduces device-related costs by approximately AUD 7.00 compared with routine removal (MD -6.96, 95% CI -9.05 to -4.86; moderate-certainty evidence, downgraded once for serious risk of bias).Secondary outcomesSix trials assessed infiltration (7123 participants). Routine replacement probably reduces infiltration of fluid into surrounding tissues compared with a clinically indicated change (RR 1.16 (95% CI 1.06 to 1.26; routine replacement 747/3638 (20.5%); clinically indicated 834/3485 (23.9%); moderate-certainty evidence, downgraded once for serious risk of bias).Meta-analysis of seven trials (7323 participants), found that rates of catheter failure due to blockage were probably lower in the routine-replacement group compared to the clinically indicated group (RR 1.14, 95% CI 1.01 to 1.29; routine-replacement 519/3733 (13.9%); clinically indicated 560/3590 (15.6%); moderate-certainty evidence, downgraded once for serious risk of bias).Four studies (4606 participants), reported local infection rates. It is uncertain if there are differences between groups (RR 4.96, 95% CI 0.24 to 102.98; clinically indicated 2/2260 (0.09%); routine replacement 0/2346 (0.0%); very low-certainty evidence, downgraded one level for serious ris

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd007798.pub3

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Cited by

See all 313

Metadata

Authors
Webster, J., Osborne, S., Rickard, C. M., & New, K.
Venue
Cochrane Database of Systematic Reviews
Published
2013-04-30
Volume
1
Issue
4
Pages
CD007798-CD007798
ISSN
1361-6137 (ISSN-L)
OpenAlex
W2163486268
Cited by
313
References
51
Type
reference entry
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinically-indicated replacement versus routine replacement of peripheral venous catheters. https://app.cochat.ai/papers/10.1002/14651858.cd007798.pub3
The paper
Webster, J., Osborne, S., Rickard, C. M., & New, K. (2013). Clinically-indicated replacement versus routine replacement of peripheral venous catheters. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd007798.pub3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.