Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 100 of the 100 references it cites were found in a registry or an index.

Airway physical examination tests for detection of difficult airway management in apparently normal adult patients

Open access
Roth, Dominik, Pace, Nathan L, Lee, Anna, Hovhannisyan, Karen, Warenits, Alexandra-Maria, Arrich, Jasmin, Herkner, Harald·2018·Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: The unanticipated difficult airway is a potentially life-threatening event during anaesthesia or acute conditions. An unsuccessfully managed upper airway is associated with serious morbidity and mortality. Several bedside screening tests are used in clinical practice to identify those at high risk of difficult airway. Their accuracy and benefit however, remains unclear. OBJECTIVES: The objective of this review was to characterize and compare the diagnostic accuracy of the Mallampati classification and other commonly used airway examination tests for assessing the physical status of the airway in adult patients with no apparent anatomical airway abnormalities. We performed this individually for each of the four descriptors of the difficult airway: difficult face mask ventilation, difficult laryngoscopy, difficult tracheal intubation, and failed intubation. SEARCH METHODS: We searched major electronic databases including CENTRAL, MEDLINE, Embase, ISI Web of Science, CINAHL, as well as regional, subject specific, and dissertation and theses databases from inception to 16 December 2016, without language restrictions. In addition, we searched the Science Citation Index and checked the references of all the relevant studies. We also handsearched selected journals, conference proceedings, and relevant guidelines. We updated this search in March 2018, but we have not yet incorporated these results. SELECTION CRITERIA: We considered full-text diagnostic test accuracy studies of any individual index test, or a combination of tests, against a reference standard. Participants were adults without obvious airway abnormalities, who were having laryngoscopy performed with a standard laryngoscope and the trachea intubated with a standard tracheal tube. Index tests included the Mallampati test, modified Mallampati test, Wilson risk score, thyromental distance, sternomental distance, mouth opening test, upper lip bite test, or any combination of these. The target condition was difficult airway, with one of the following reference standards: difficult face mask ventilation, difficult laryngoscopy, difficult tracheal intubation, and failed intubation. DATA COLLECTION AND ANALYSIS: We performed screening and selection of the studies, data extraction and assessment of methodological quality (using QUADAS-2) independently and in duplicate. We designed a Microsoft Access database for data collection and used Review Manager 5 and R for data analysis. For each index test and each reference standard, we assessed sensitivity and specificity. We produced forest plots and summary receiver operating characteristic (ROC) plots to summarize the data. Where possible, we performed meta-analyses to calculate pooled estimates and compare test accuracy indirectly using bivariate models. We investigated heterogeneity and performed sensitivity analyses. MAIN RESULTS: We included 133 (127 cohort type and 6 case-control) studies involving 844,206 participants. We evaluated a total of seven different prespecified index tests in the 133 studies, as well as 69 non-prespecified, and 32 combinations. For the prespecified index tests, we found six studies for the Mallampati test, 105 for the modified Mallampati test, six for the Wilson risk score, 52 for thyromental distance, 18 for sternomental distance, 34 for the mouth opening test, and 30 for the upper lip bite test. Difficult face mask ventilation was the reference standard in seven studies, difficult laryngoscopy in 92 studies, difficult tracheal intubation in 50 studies, and failed intubation in two studies. Across all studies, we judged the risk of bias to be variable for the different domains; we mostly observed low risk of bias for patient selection, flow and timing, and unclear risk of bias for reference standard and index test. Applicability concerns were generally low for all domains. For difficult laryngoscopy, the summary sensitivity ranged from 0.22 (95% confidence interval (CI) 0.13 to 0.33; mouth opening test) to 0.67 (95% CI 0.45 to 0.83; upper lip bite test) and the summary specificity ranged from 0.80 (95% CI 0.74 to 0.85; modified Mallampati test) to 0.95 (95% CI 0.88 to 0.98; Wilson risk score). The upper lip bite test for diagnosing difficult laryngoscopy provided the highest sensitivity compared to the other tests (P < 0.001). For difficult tracheal intubation, summary sensitivity ranged from 0.24 (95% CI 0.12 to 0.43; thyromental distance) to 0.51 (95% CI 0.40 to 0.61; modified Mallampati test) and the summary specificity ranged from 0.87 (95% CI 0.82 to 0.91; modified Mallampati test) to 0.93 (0.87 to 0.96; mouth opening test). The modified Mallampati test had the highest sensitivity for diagnosing difficult tracheal intubation compared to the other tests (P < 0.001). For difficult face mask ventilation, we could only estimate summary sensitivity (0.17, 95% CI 0.06 to 0.39) and specificity (0.90, 95% CI 0.81 to 0.95) for the modified Mallampati test. AUTHORS' CONCLUS

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd008874.pub2

Cites

100 of 100 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 100 references

Cited by

See all 257

Metadata

Authors
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A.-M., Arrich, J., & Herkner, H.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2018-05-15
Volume
5
Pages
CD008874-CD008874
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2120360204
Cited by
257
References
100
FWCI
30.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Airway physical examination tests for detection of difficult airway management in apparently normal adult patients. https://app.cochat.ai/papers/10.1002/14651858.cd008874.pub2
The paper
Roth, D., Pace, N. L., Lee, A., Hovhannisyan, K., Warenits, A.-M., Arrich, J., & Herkner, H. (2018). Airway physical examination tests for detection of difficult airway management in apparently normal adult patients. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd008874.pub2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.