The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
The effects of high perioperative inspiratory oxygen fraction for adult surgical patients
Open accessAbstract
BACKGROUND: Available evidence on the effects of a high fraction of inspired oxygen (FIO2) of 60% to 90% compared with a routine fraction of inspired oxygen of 30% to 40%, during anaesthesia and surgery, on mortality and surgical site infection has been inconclusive. Previous trials and meta-analyses have led to different conclusions on whether a high fraction of supplemental inspired oxygen during anaesthesia may decrease or increase mortality and surgical site infections in surgical patients. OBJECTIVES: To assess the benefits and harms of an FIO2 equal to or greater than 60% compared with a control FIO2 at or below 40% in the perioperative setting in terms of mortality, surgical site infection, respiratory insufficiency, serious adverse events and length of stay during the index admission for adult surgical patients.We looked at various outcomes, conducted subgroup and sensitivity analyses, examined the role of bias and applied trial sequential analysis (TSA) to examine the level of evidence supporting or refuting a high FIO2 during surgery, anaesthesia and recovery. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, BIOSIS, International Web of Science, the Latin American and Caribbean Health Science Information Database (LILACS), advanced Google and the Cumulative Index to Nursing and Allied Health Literature (CINAHL) up to February 2014. We checked the references of included trials and reviews for unidentified relevant trials and reran the searches in March 2015. We will consider two studies of interest when we update the review. SELECTION CRITERIA: We included randomized clinical trials that compared a high fraction of inspired oxygen with a routine fraction of inspired oxygen during anaesthesia, surgery and recovery in individuals 18 years of age or older. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently. We conducted random-effects and fixed-effect meta-analyses, and for dichotomous outcomes, we calculated risk ratios (RRs). We used published data and data obtained by contacting trial authors.To minimize the risk of systematic error, we assessed the risk of bias of the included trials. To reduce the risk of random errors caused by sparse data and repetitive updating of cumulative meta-analyses, we applied trial sequential analyses. We used Grades of Recommendation, Assessment, Development and Evaluation (GRADE) to assess the quality of the evidence. MAIN RESULTS: We included 28 randomized clinical trials (9330 participants); in the 21 trials reporting relevant outcomes for this review, 7597 participants were randomly assigned to a high fraction of inspired oxygen versus a routine fraction of inspired oxygen.In trials with an overall low risk of bias, a high fraction of inspired oxygen compared with a routine fraction of inspired oxygen was not associated with all-cause mortality (random-effects model: RR 1.12, 95% confidence interval (CI) 0.93 to 1.36; GRADE: low quality) within the longest follow-up and within 30 days of follow-up (Peto odds ratio (OR) 0.99, 95% CI 0.61 to 1.60; GRADE: low quality). In a trial sequential analysis, the required information size was not reached and the analysis could not refute a 20% increase in mortality. Similarly, when all trials were included, a high fraction of inspired oxygen was not associated with all-cause mortality to the longest follow-up (RR 1.07, 95% CI 0.87 to 1.33) or within 30 days of follow-up (Peto OR 0.83, 95% CI 0.54 to 1.29), both of very low quality according to GRADE. Neither was a high fraction of inspired oxygen associated with the risk of surgical site infection in trials with low risk of bias (RR 0.86, 95% CI 0.63 to 1.17; GRADE: low quality) or in all trials (RR 0.87, 95% CI 0.71 to 1.07; GRADE: low quality). A high fraction of inspired oxygen was not associated with respiratory insufficiency (RR 1.25, 95% CI 0.79 to 1.99), serious adverse events (RR 0.96, 95% CI 0.65 to 1.43) or length of stay (mean difference -0.06 days, 95% CI -0.44 to 0.32 days).In subgroup analyses of nine trials using preoperative antibiotics, a high fraction of inspired oxygen was associated with a decrease in surgical site infections (RR 0.76, 95% CI 0.60 to 0.97; GRADE: very low quality); a similar effect was noted in the five trials adequately blinded for the outcome assessment (RR 0.79, 95% CI 0.66 to 0.96; GRADE: very low quality). We did not observe an effect of a high fraction of inspired oxygen on surgical site infections in any other subgroup analyses. AUTHORS' CONCLUSIONS: As the risk of adverse events, including mortality, may be increased by a fraction of inspired oxygen of 60% or higher, and as robust evidence is lacking for a beneficial effect of a fraction of inspired oxygen of 60% or higher on surgical site infection, our overall results suggest that evidence is insufficient to support the routine use of a high fraction of inspired oxygen during anaesthesia and surg
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Schietroma, M., Carlei, F., Cecilia, E. M., Piccione, F., Bianchi, Z., & Amicucci, G. (2014) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-013-2378-z · Cited by 37
RetractedSPIRIT 2013 Statement: Defining Standard Protocol Items for Clinical Trials
Chan, A.-W., Tetzlaff, J. M., Altman, D. G., Laupacis, A., Gøtzsche, P. C., Krleža-Jerić, K., Hróbjartsson, A., Mann, H., Dickersin, K., Berlin, J. A., et al. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-158-3-201302050-00583 · Cited by 7,363
Moher, D., Pham, B., Jones, A., Cook, D. J., Jadad, A. R., Moher, M., Tugwell, P., & Klassen, T. P. (1998) · The Lancet · doi:10.1016/s0140-6736(98)01085-x · Cited by 3,560
GRADE guidelines 6. Rating the quality of evidence—imprecision
Guyatt, G. H., Oxman, A. D., Kunz, R., Brozek, J., Alonso-Coello, P., Rind, D., Devereaux, P. J., Montori, V. M., Freyschuss, B., Vist, G., et al. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2011.01.012 · Cited by 2,693
Wood, L., Egger, M., Gluud, L. L., Schulz, K. F., Jüni, P., Altman, D. G., Gluud, C., Martin, R. M., Wood, A. J. G., & Sterne, J. A. C. (2008) · BMJ · doi:10.1136/bmj.39465.451748.ad · Cited by 2,538
Self-citationDiscrete sequential boundaries for clinical trials
GORDON LAN, K. K., & DEMETS, D. L. (1983) · Biometrika · doi:10.1093/biomet/70.3.659 · Cited by 2,310
What is meant by intention to treat analysis? Survey of published randomised controlled trials
Hollis, S., & Campbell, F. (1999) · BMJ · doi:10.1136/bmj.319.7211.670 · Cited by 2,160
Trial sequential analysis may establish when firm evidence is reached in cumulative meta-analysis
Wetterslev, J., Thorlund, K., Brok, J., & Gluud, C. (2008) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2007.03.013 · Cited by 1,881
Self-citationChan, A.-W., Hróbjartsson, A., Haahr, M. T., Gøtzsche, P. C., & Altman, D. G. (2004) · JAMA · doi:10.1001/jama.291.20.2457 · Cited by 1,845
Scope and Impact of Financial Conflicts of Interest in Biomedical Research: A Systematic Review
Bekelman, J. E., Li, Y., & Gross, C. P. (2003) · JAMA · doi:10.1001/jama.289.4.454 · Cited by 1,816
Cited by
Kozek-Langenecker, S. A., Ahmed, A. B., Afshari, A., Albaladejo, P., Aldecoa, C., Barauskas, G., De Robertis, E., Faraoni, D., Filipescu, D. C., Fries, D., et al. (2017) · European Journal of Anaesthesiology · doi:10.1097/eja.0000000000000630 · Cited by 800
Surgical Site Infection Prevention: A Review
Seidelman, J. L., Mantyh, C. R., & Anderson, D. J. (2023) · JAMA · doi:10.1001/jama.2022.24075 · Cited by 553
Strategies to prevent surgical site infections in acute-care hospitals: 2022 Update
Calderwood, M. S., Anderson, D. J., Bratzler, D. W., Dellinger, E. P., Garcia-Houchins, S., Maragakis, L. L., Nyquist, A.-C., Perkins, K. M., Preas, M. A., Saiman, L., et al. (2023) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2023.67 · Cited by 307
Oxygen therapy for acutely ill medical patients: a clinical practice guideline
Siemieniuk, R. A. C., Chu, D. K., Kim, L. H.-Y., Güell-Rous, M.-R., Alhazzani, W., Soccal, P. M., Karanicolas, P. J., Farhoumand, P. D., Siemieniuk, J. L. K., Satia, I., et al. (2018) · BMJ · doi:10.1136/bmj.k4169 · Cited by 281
Effect of intraoperative hyperoxia on the incidence of surgical site infections: a meta-analysis
Cohen, B., Schacham, Y. N., Ruetzler, K., Ahuja, S., Yang, D., Mascha, E. J., Barclay, A. B., Hung, M. H., & Sessler, D. I. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.02.027 · Cited by 59
Metadata
- Authors
- Wetterslev, J., Meyhoff, C. S., Jørgensen, L. N., Gluud, C., Lindschou, J., & Rasmussen, L. S.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2015-06-25
- Volume
- 2016
- Issue
- 9
- Pages
- CD008884-CD008884
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W2131653244
- Cited by
- 166
- References
- 18
- FWCI
- 14.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The effects of high perioperative inspiratory oxygen fraction for adult surgical patients. https://app.cochat.ai/papers/10.1002/14651858.cd008884.pub2
- The paper
- Wetterslev, J., Meyhoff, C. S., Jørgensen, L. N., Gluud, C., Lindschou, J., & Rasmussen, L. S. (2015). The effects of high perioperative inspiratory oxygen fraction for adult surgical patients. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd008884.pub2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.