CoChat

Robotic surgery for benign gynaecological disease

Liu, Hongqian, Lu, DongHao, Wang, Lei, Shi, Gang, Song, Huan, Clarke, Jane · 2012 · Cochrane Database of Systematic Reviews
Cited by 114

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Robotic surgery is the latest innovation in the field of minimally invasive surgery. In the case of robotic surgery, instead of directly moving the instruments the surgeon uses a robotic system to control the instruments for surgical procedures. Robotic surgical systems have been used in various gynaecological surgeries for benign disease, such as hysterectomy (removal of the uterus), myomectomy (removal of uterine leiomyomas) and tubal reanastomosis (the reuniting of a divided tube). The mounting evidence demonstrates the feasibility and safety of robotic surgery in benign gynaecological disease. Robotic surgery is advertised as having promising advantages including more precise vision and procedures, improved ergonomics and shorter length of hospital stay. However, the main disadvantages of the robotic surgical system should not be overlooked, including the high cost of disposable instruments and retraining for both surgeons and nurses. OBJECTIVES: To assess the effectiveness and safety of robot-assisted surgery in the treatment of benign gynaecological disease. SEARCH METHODS: We searched the Cochrane Menstrual Disorders and Subfertility Group's Trial Register, the Cochrane Central Register of Controlled Trials (CENTRAL) (Issue 2, 2011), MEDLINE and EMBASE up to November 2011 and citation lists of relevant publications. SELECTION CRITERIA: All randomised controlled trials (RCTs) comparing robotic surgery for benign gynaecological disease to laparoscopic or open surgical procedures. RCTs comparing different types of robotic assistants were also included. We contacted study authors for unpublished information, but failed in obtaining a response. DATA COLLECTION AND ANALYSIS: Two review authors independently screened studies for inclusion. The domains assessed for risk of bias were allocation concealment, blinding, incomplete outcome data and selective outcome reporting. Odds ratios (OR) were used for reporting dichotomous data with 95% confidence intervals (CI), whilst mean differences (MD) were determined for continuous data. Statistical heterogeneity was assessed using the I(2) statistic. We contacted the primary authors for missing data but failed in obtaining a response. MAIN RESULTS: Two trials involving 158 participants were included. Since one included trial was published in conference proceedings, limited usable data were available for further analysis. The only analysis in this trial showed comparable rates of conversions to open surgery between the robotic group and the laparoscopic group (OR 1.41, 95% CI 0.22 to 9.01; P = 0.72). One RCT showed longer operation time (MD 66.00, 95% CI 40.93 to 91.07; P < 0.00001), higher cost (MD 1936.00, 95% CI 445.69 to 3426.31; P = 0.01) in the robotic group compared with the laparoscopic group. Also, both studies reported that robotic and laparoscopic surgery seemed comparable regarding intraoperative outcome, complications, length of hospital stay and quality of life. AUTHORS' CONCLUSIONS: Currently, the limited evidence showed that robotic surgery did not benefit women with benign gynaecological disease in effectiveness or in safety. Further well-designed RCTs with complete reported data are required to confirm or refute this conclusion.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd008978.pub2This paper is marked retracted.

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 114

Metadata

Authors
Liu, H., Lu, D., Wang, L., Shi, G., Song, H., & Clarke, J.
Venue
Cochrane Database of Systematic Reviews
Published
2012-02-15
Issue
2
Pages
CD008978-CD008978
ISSN
1361-6137 (ISSN-L)
OpenAlex
W1892929848
Cited by
114
References
1
Type
reference entry
Language
en
Status
Retracted
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.