Localization techniques for guided surgical excision of non-palpable breast lesions
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Breast cancer is the most common form of cancer and the second leading cause of death amongst women in Europe. Amongst five invasive cancers per 1000 women detected in screening, 2.7 were < 15 mm in diameter; and others reported that over one third of excised breast lesions were clinically occult. The challenge is to accurately locate small non-palpable lesions intraoperatively for optimal therapeutic outcome. A secondary important goal is to remove the smallest amount possible of healthy glandular tissue for optimal cosmesis. Currently the most widely adopted approach (80% in one survey) in guided breast-conserving surgery for excising non-palpable breast lesions is wire-guided localization (WGL). With the clinical setting shifting towards earlier non-palpable breast lesions being detected through screening, we investigated whether the current standard in assisting surgical excision of these lesions, WGL, yields the best therapeutic outcome for women with breast cancer. OBJECTIVES: To assess the therapeutic outcomes of any new form of guided surgical intervention for non-palpable breast lesions against wire-guided localization, the current gold standard. SEARCH METHODS: We searched the Cochrane Breast Cancer Group's (CBCG) Specialized Register, MEDLINE (via PubMed), the Cochrane Central Register of Controlled Trials (CENTRAL), and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) search portal from the earliest available date up to 30 March 2015. We also handsearched recent conference proceedings and sought information from experts in the field. SELECTION CRITERIA: Two review authors, BC and RJ, independently screened by title and abstract the studies we had identified through the search strategy; when this was inconclusive, they examined the full-text article for inclusion. We resolved any discrepancies regarding eligibility by discussion with a third review author, RA. DATA COLLECTION AND ANALYSIS: Three review authors, BC, JW, and RJ, independently extracted data using a standardized data sheet. We performed all analyses using Review Manager (RevMan) or the R meta package, and in accordance with the Cochrane Handbook for Systematic Reviews of Interventions. We reported results via a graphical assessment using forest plots showing the study estimates. We considered and discussed additional subgroup and sensitivity analyses. MAIN RESULTS: We identified 11 randomized controlled trials (RCTs) that met the inclusion criteria of this Cochrane review and included eight trials in the meta-analyses. Six RCTs compared radioguided occult lesion localization (ROLL) versus WGL, and two RCTs compared radioactive iodine ((125)I) seed localization (RSL) versus WGL. Of the three remaining trials, one RCT compared cryo-assisted techniques (CAL) versus WGL, one compared intraoperative ultrasound-guided lumpectomy (IOUS) versus WGL, and one compared modified ROLL technique in combination with methylene dye (RCML) versus WGL. Of the trials we included in the meta-analysis, there were a total of 1273 participants with non-palpable breast lesions (627 participants (WGL); 443 participants (ROLL); and 203 participants (RSL)). The participant population varied considerably between included trials, which included participants with both non-palpable benign and malignant lesions, and varied in defining clear margins. The included trials did not report any long-term outcomes.In general, the outcomes of WGL, ROLL and RSL were comparable.ROLL demonstrated favourable results in successful localization (risk ratio (RR) 0.60, 95% confidence interval (CI) 0.16 to 2.28; 869 participants; six trials), positive excision margins (RR 0.74, 95% CI 0.42 to 1.29; 517 participants; five trials), and re-operation rates (RR 0.51, 95% CI 0.21 to 1.23; 583 participants; four trials) versus WGL, but none were statistically significant. WGL was significantly superior to RSL in successfully localizing non-palpable lesions (RR 3.85, 95% CI 1.21 to 12.19; 402 participants; two trials). However, for successful excision, ROLL and RSL have comparable outcomes versus WGL (ROLL versus WGL: RR 1.00, 95% CI 0.99 to 1.01; 871 participants; six trials; RSL versus WGL: RR 1.00, 95% CI 0.99 to 1.01; 402 participants; two trials). These findings were similar in that RSL demonstrated favourable results over WGL in positive tumour margins (RR 0.67, 95% CI 0.43 to 1.06; 366 participants; two trials), and re-operation rates (RR 0.80, 95% CI 0.48 to 1.32; 305 participants; one trial) but neither reached statistical significance. In contrast, WGL had fewer postoperative complications to both ROLL (RR 1.18, 95% CI 0.71 to 1.98; 642 participants; four trials) and RSL (RR 1.51, 95% CI 0.75 to 3.03; 305 participants; one trial), although this was also not statistically significant.The overall quality of evidence was good. The main risk of bias amongst included studies consisted of incomplete data sets, selective reporting, a
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fisher, B., Anderson, S., Bryant, J., Margolese, R. G., Deutsch, M., Fisher, E. R., Jeong, J.-H., & Wolmark, N. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa022152 · Cited by 6,249
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634
Investigating and dealing with publication and other biases in meta-analysis
Sterne, J. A. C., Egger, M., & Smith, G. D. (2001) · BMJ · doi:10.1136/bmj.323.7304.101 · Cited by 2,225
A consumer's guide to subgroup analyses
Oxman, A. D., & Guyatt, G. H. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-116-1-78 · Cited by 914
Sterne, J. A. C., & Harbord, R. M. (2004) · The Stata Journal: Promoting communications on statistics and Stata · doi:10.1177/1536867x0400400204 · Cited by 708
Metadata
- Authors
- Chan, B. K., Wiseberg-Firtell, J. A., Jois, R. H., Jensen, K., & Audisio, R. A.
- Venue
- Cochrane Database of Systematic Reviews
- Publisher
- Wiley
- Published
- 2015-12-31
- Volume
- 2016
- Issue
- 3
- Pages
- CD009206-CD009206
- ISSN
- 1361-6137 (ISSN-L)
- 1465-1858
- OpenAlex
- W1930770363
- Cited by
- 190
- References
- 5
- FWCI
- 10.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Localization techniques for guided surgical excision of non-palpable breast lesions. https://app.cochat.ai/papers/10.1002/14651858.cd009206.pub2
- The paper
- Chan, B. K., Wiseberg-Firtell, J. A., Jois, R. H., Jensen, K., & Audisio, R. A. (2015). Localization techniques for guided surgical excision of non-palpable breast lesions. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd009206.pub2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.