Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Semi-recumbent position versus supine position for the prevention of ventilator-associated pneumonia in adults requiring mechanical ventilation

Open access
Wang, Li, Li, Xiao, Yang, Zongxia, Tang, Xueli, Yuan, Qiang, Deng, Lijing, Sun, Xin · 2016 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Ventilator-associated pneumonia (VAP) is associated with increased mortality, prolonged length of hospital stay and increased healthcare costs in critically ill patients. Guidelines recommend a semi-recumbent position (30º to 45º) for preventing VAP among patients requiring mechanical ventilation. However, due to methodological limitations in existing systematic reviews, uncertainty remains regarding the benefits and harms of the semi-recumbent position for preventing VAP. OBJECTIVES: To assess the effectiveness and safety of semi-recumbent positioning versus supine positioning to prevent ventilator-associated pneumonia (VAP) in adults requiring mechanical ventilation. SEARCH METHODS: We searched CENTRAL (2015, Issue 10), which includes the Cochrane Acute Respiratory Infections Group's Specialised Register, MEDLINE (1946 to October 2015), EMBASE (2010 to October 2015), CINAHL (1981 to October 2015) and the Chinese Biomedical Literature Database (CBM) (1978 to October 2015). SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing semi-recumbent versus supine positioning (0º to 10º), or RCTs comparing alternative degrees of positioning in mechanically ventilated patients. Our outcomes included clinically suspected VAP, microbiologically confirmed VAP, intensive care unit (ICU) mortality, hospital mortality, length of ICU stay, length of hospital stay, duration of ventilation, antibiotic use and any adverse events. DATA COLLECTION AND ANALYSIS: Two review authors independently and in duplicate screened titles, abstracts and full texts, assessed risk of bias and extracted data using standardised forms. We calculated the mean difference (MD) and 95% confidence interval (95% CI) for continuous data and the risk ratio (RR) and 95% CI for binary data. We performed meta-analysis using the random-effects model. We used the grading of recommendations, assessment, development and evaluation (GRADE) approach to grade the quality of evidence. MAIN RESULTS: We included 10 trials involving 878 participants, among which 28 participants in two trials did not provide complete data due to loss to follow-up. We judged all trials to be at high risk of bias. Semi-recumbent position (30º to 60º) versus supine position (0° to 10°) A semi-recumbent position (30º to 60º) significantly reduced the risk of clinically suspected VAP compared to a 0º to 10º supine position (eight trials, 759 participants, 14.3% versus 40.2%, RR 0.36; 95% CI 0.25 to 0.50; risk difference (RD) 25.7%; 95% CI 20.1% to 30.1%; GRADE: moderate quality evidence).There was no significant difference between the two positions in the following outcomes: microbiologically confirmed VAP (three trials, 419 participants, 12.6% versus 31.6%, RR 0.44; 95% CI 0.11 to 1.77; GRADE: very low quality evidence), ICU mortality (two trials, 307 participants, 29.8% versus 34.3%, RR 0.87; 95% CI 0.59 to 1.27; GRADE: low quality evidence), hospital mortality (three trials, 346 participants, 23.8% versus 27.6%, RR 0.84; 95% CI 0.59 to 1.20; GRADE: low quality evidence), length of ICU stay (three trials, 346 participants, MD -1.64 days; 95% CI -4.41 to 1.14 days; GRADE moderate quality evidence), length of hospital stay (two trials, 260 participants, MD -9.47 days; 95% CI -34.21 to 15.27 days; GRADE: very low quality evidence), duration of ventilation (four trials, 458 participants, MD -3.35 days; 95% CI -7.80 to 1.09 days), antibiotic use (three trials, 284 participants, 84.8% versus 84.2%, RR 1.00; 95% CI 0.97 to 1.03) and pressure ulcers (one trial, 221 participants, 28% versus 30%, RR 0.91; 95% CI 0.60 to 1.38; GRADE: low quality evidence). No other adverse events were reported. Semi-recumbent position (45°) versus 25° to 30° We found no statistically significant differences in the following prespecified outcomes: clinically suspected VAP (two trials, 91 participants, RR 0.74; 95% CI 0.35 to 1.56; GRADE: very low quality evidence), microbiologically confirmed VAP (one trial, 30 participants, RR 0.61; 95% CI 0.20 to 1.84: GRADE: very low quality evidence), ICU mortality (one trial, 30 participants, RR 0.57; 95% CI 0.15 to 2.13; GRADE: very low quality evidence), hospital mortality (two trials, 91 participants, RR 1.00; 95% CI 0.38 to 2.65; GRADE: very low quality evidence), length of ICU stay (one trial, 30 participants, MD 1.6 days; 95% CI -0.88 to 4.08 days; GRADE: very low quality evidence) and antibiotic use (two trials, 91 participants, RR 1.11; 95% CI 0.84 to 1.47). No adverse events were reported. AUTHORS' CONCLUSIONS: A semi-recumbent position (≧ 30º) may reduce clinically suspected VAP compared to a 0° to 10° supine position. However, the evidence is seriously limited with a high risk of bias. No adequate evidence is available to draw any definitive conclusion on other outcomes and the comparison of alternative semi-recumbent positions. Adverse events, particularly venous thromboembolism, were under-reported.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd009946.pub2

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 166

Metadata

Authors
Wang, L., Li, X., Yang, Z., Tang, X., Yuan, Q., Deng, L., & Sun, X.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2016-01-08
Volume
2016
Issue
1
Pages
CD009946-CD009946
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2139672321
Cited by
166
References
4
FWCI
13.93
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Semi-recumbent position versus supine position for the prevention of ventilator-associated pneumonia in adults requiring mechanical ventilation. https://app.cochat.ai/papers/10.1002/14651858.cd009946.pub2
The paper
Wang, L., Li, X., Yang, Z., Tang, X., Yuan, Q., Deng, L., & Sun, X. (2016). Semi-recumbent position versus supine position for the prevention of ventilator-associated pneumonia in adults requiring mechanical ventilation. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd009946.pub2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.