The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Performance of the Ozone Mapping and Profiler Suite (OMPS) products
Open accessAbstract
NOAA, through the Joint Polar Satellite System (JPSS) program, in partnership with the National Aeronautical and Space Administration, launched the Suomi National Polar‐orbiting Partnership (S‐NPP) satellite, a risk reduction and data continuity mission, on 28 October 2011. The JPSS program is executing the S‐NPP Calibration and Validation program to ensure that the data products comply with the requirements of the sponsoring agencies. The Ozone Mapping and Profiler Suite (OMPS) consists of two telescopes feeding three detectors measuring solar radiance scattered by the Earth's atmosphere directly and solar irradiance by using diffusers. The measurements are used to generate estimates of total column ozone and vertical ozone profiles for use in near‐real‐time applications and extension of ozone climate data records. The calibration and validation efforts are progressing well, and both Level 1 (Sensor Data Records) and Level 2 (Ozone Environmental Data Records) have advanced to release at Provisional Maturity. This paper provides information on the product performance over the first 22 months of the mission. The products are evaluated through the use of internal consistency analysis techniques and comparisons to other satellite instrument and ground‐based products. The initial performance finds total ozone showing negative bias of 2 to 4% with respect to correlative products and ozone profiles often within ±5% in the middle and upper stratosphere of current operational products. Potential improvements in the measurements and algorithms are identified. These will be implemented in coming months to reduce the differences further.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Algorithm for the estimation of vertical ozone profiles from the backscattered ultraviolet technique
Bhartia, P. K., McPeters, R. D., Mateer, C. L., Flynn, L. E., & Wellemeyer, C. (1996) · Journal of Geophysical Research: Atmospheres · doi:10.1029/96jd01165 · Cited by 235
Self-citationSolar Backscatter UV (SBUV) total ozone and profile algorithm
Bhartia, P. K., McPeters, R. D., Flynn, L. E., et al. (2013) · Atmospheric measurement techniques · doi:10.5194/amt-6-2533-2013 · Cited by 165
Self-citationDobson spectrophotometer 83: A standard for total ozone measurements, 1962–1987
Komhyr, W. D., Grass, R. D., & Leonard, R. K. (1989) · Journal of Geophysical Research Atmospheres · doi:10.1029/jd094id07p09847 · Cited by 147
Seftor, C. J., Jaross, G., Kowitt, M., Haken, M., Li, J., & Flynn, L. E. (2014) · Journal of Geophysical Research Atmospheres · doi:10.1002/2013jd020472 · Cited by 126
Self-citationOMPS Limb Profiler instrument performance assessment
Jaross, G., Bhartia, P. K., Chen, G., Kowitt, M., Haken, M., Chen, Z., Xu, P., Warner, J., & Kelly, T. (2013) · Journal of Geophysical Research Atmospheres · doi:10.1002/2013jd020482 · Cited by 125
Rault, D., & Loughman, R. P. (2012) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/tgrs.2012.2213093 · Cited by 114
Wu, X., Liu, Q., Zeng, J., Grotenhuis, M. G., Qian, H., Caponi, M. Z., Flynn, L., Jaross, G., Sen, B., Buss, R. H., et al. (2014) · Journal of Geophysical Research Atmospheres · doi:10.1002/2013jd020484 · Cited by 29
Self-citation
Cited by
Aura OMI observations of regional SO 2 and NO 2 pollution changes from 2005 to 2015
Krotkov, N. A., McLinden, C. A., Li, C., Lamsal, L. N., Celarier, E. A., Marchenko, S. V., Swartz, W. H., Bucsela, E. J., Joiner, J., Duncan, B. N., et al. (2016) · Atmospheric Chemistry and Physics · doi:10.5194/acp-16-4605-2016 · Cited by 764
The Ozone Monitoring Instrument: overview of 14 years in space
Levelt, P. F., Joiner, J., Tamminen, J., Veefkind, J. P., Bhartia, P. K., Stein Zweers, D. C., Duncan, B. N., Streets, D. G., Eskes, H., van der A, R., et al. (2018) · Atmospheric Chemistry and Physics · doi:10.5194/acp-18-5699-2018 · Cited by 481
Kim, J., Jeong, U., Ahn, M.-H., Kim, J. H., Park, R. J., Lee, H., Song, C. H., Choi, Y.-S., Lee, K.-H., Yoo, J.-M., et al. (2020) · Bulletin of the American Meteorological Society · doi:10.1175/bams-d-18-0013.1 · Cited by 439
De Mazière, M., Thompson, A. M., Kurylo, M. J., Wild, J. D., Bernhard, G., Blumenstock, T., Braathen, G. O., Hannigan, J. W., Lambert, J.-C., Leblanc, T., et al. (2018) · Atmospheric Chemistry and Physics · doi:10.5194/acp-18-4935-2018 · Cited by 378
Self-citationBais, A. F., Lucas, R. M., Bornman, J. F., Williamson, C. E., Sulzberger, B., Austin, A. T., Wilson, S. R., Andrady, A. L., Bernhard, G., McKenzie, R. L., et al. (2018) · Photochemical & Photobiological Sciences · doi:10.1039/c7pp90043k · Cited by 350
Metadata
- Authors
- Flynn, L., Long, C., Wu, X., Evans, R., Beck, C. T., Petropavlovskikh, I., McConville, G., Yu, W., Zhang, Z., Niu, J., Beach, E., Hao, Y., Pan, C., Sen, B., Novicki, M., Zhou, S., & Seftor, C.
- Venue
- Journal of Geophysical Research: Atmospheres
- Publisher
- American Geophysical Union (AGU)
- Published
- 2014-05-20
- Volume
- 119
- Issue
- 10
- Pages
- 6181-6195
- ISSN
- 0148-0227 (ISSN-L)
- 2169-897X
- 2169-8996
- OpenAlex
- W1892260413
- Cited by
- 258
- References
- 7
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of the Ozone Mapping and Profiler Suite (OMPS) products. https://app.cochat.ai/papers/10.1002/2013jd020467
- The paper
- Flynn, L., Long, C., Wu, X., Evans, R., Beck, C. T., Petropavlovskikh, I., McConville, G., Yu, W., Zhang, Z., Niu, J., Beach, E., Hao, Y., Pan, C., Sen, B., Novicki, M., Zhou, S., & Seftor, C. (2014). Performance of the Ozone Mapping and Profiler Suite (OMPS) products. Journal of Geophysical Research: Atmospheres. https://doi.org/10.1002/2013jd020467
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.