Pore‐by‐pore capillary pressure measurements using X ‐ray microtomography at reservoir conditions: Curvature, snap‐off, and remobilization of residual CO 2
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
X‐ray microtomography was used to image the shape and size of residual ganglia of supercritical CO 2 at resolutions of 3.5 and 2 μm and at representative subsurface conditions of temperature and pressure. The capillary pressure for each ganglion was found by measuring the curvature of the CO 2 ‐brine interface, while the pore structure was parameterized using distance maps of the pore space. The formation of the residual clusters by snap‐off was examined by comparing the ganglion capillary pressure to local pore topography. The capillary pressure was found to be inversely proportional to the radius of the largest restriction (throat) surrounding the ganglion, which validates the imbibition mechanisms used in pore‐network modeling. The potential mobilization of residual ganglia was assessed using a reformulation of both the capillary ( N cmacro ) and Bond numbers ( N bmacro ), rigorously based on a balance of pore‐scale forces, with the majority of ganglia remobilized at N cmacro around 1. Buoyancy forces were found to be small in this system ( N bmacro << 1), meaning the gravitational remobilization of CO 2 after residual trapping would be extremely difficult.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Non-Local Algorithm for Image Denoising
Buades, A., Coll, B., & Morel, J.-M. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.38 · Cited by 7,616 · cited 1×
“After acquisition, the images were filtered using a nonlocal means edge preserving filter [Buades et al., 2005, 2008] before being corrected for any beam hardening or softening artifacts created during acquisition by subtracting a fitted second-order polynomial surface, assumed to be constant in…”
MethodThe theory of Ostwald ripening
Voorhees, P. W. (1985) · Journal of Statistical Physics · doi:10.1007/bf01017860 · Cited by 2,087
Lackner, K. S. (2003) · Science · doi:10.1126/science.1079033 · Cited by 1,290 · cited 1×
“They are, however, associated with uncertainties in seal characterization and seismic risk [Hawkes et al., 2005; IPCC, 2007; Lackner, 2003].”
Metadata
- Authors
- Andrew, M., Bijeljic, B., & Blunt, M. J.
- Venue
- Water Resources Research
- Publisher
- American Geophysical Union (AGU)
- Published
- 2014-11
- Volume
- 50
- Issue
- 11
- Pages
- 8760-8774
- ISSN
- 0043-1397 (ISSN-L)
- 1944-7973
- OpenAlex
- W2075213792
- Cited by
- 163
- References
- 3
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pore‐by‐pore capillary pressure measurements using X ‐ray microtomography at reservoir conditions: Curvature, snap‐off, and remobilization of residual CO 2. https://app.cochat.ai/papers/10.1002/2014wr015970
- The paper
- Andrew, M., Bijeljic, B., & Blunt, M. J. (2014). Pore‐by‐pore capillary pressure measurements using X ‐ray microtomography at reservoir conditions: Curvature, snap‐off, and remobilization of residual CO 2. Water Resources Research. https://doi.org/10.1002/2014wr015970
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.