Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 490

The DOI matches its Crossref record.

Fibre Optic Methods for Structural Health Monitoring

Glišić, Branko, Inaudi, Daniele · 2007 · Wiley eBooks

Abstract

Foreword. Preface. Acknowledgments. 1 Introduction to Structural Health Monitoring. 1.1 Basic Notions, Needs and Benefits. 1.1.1 Introduction. 1.1.2 Basic Notions. 1.1.3 Monitoring Needs and Benefits. 1.1.4 Whole Lifespan Monitoring. 1.2 The Structural Health Monitoring Process. 1.2.1 Core Activities. 1.2.2 Actors. 1.3 On-Site Example of Structural Health Monitoring Project. 2 Fibre-Optic Sensors. 2.1 Introduction to Fibre-Optic Technology. 2.2 Fibre-Optic Sensing Technologies. 2.2.1 SOFO Interferometric Sensors. 2.2.2 Fabry-Perot Interferometric Sensors. 2.2.3 Fibre Bragg-Grating Sensors. 2.2.4 Distributed Brillouin- and Raman-Scattering Sensors. 2.3 Sensor Packaging. 2.4 Distributed Sensing Cables. 2.4.1 Introduction. 2.4.2 Temperature-Sensing Cable. 2.4.3 Strain-Sensing Tape: SMARTape. 2.4.4 Combined Strain- and Temperature-Sensing: SMARTprofile. 2.5 Software and System Integration. 2.6 Conclusions and Summary. 3 Fibre-Optic Deformation Sensors: Applicability and Interpretation of Measurements. 3.1 Strain Components and Strain Time Evolution. 3.1.1 Basic Notions. 3.1.2 Elastic and Plastic Structural Strain. 3.1.3 Thermal Strain. 3.1.4 Creep. 3.1.5 Shrinkage. 3.1.6 Reference Time and Reference Measurement. 3.2 Sensor Gauge Length and Measurement. 3.2.1 Introduction. 3.2.2 Deformation Sensor Measurements. 3.2.3 Global Structural Monitoring: Basic Notions. 3.2.4 Sensor Measurement Dependence on Strain Distribution: Maximal Gauge Length. 3.2.5 Sensor Measurement in Inhomogeneous Materials: Minimal-Gauge Length. 3.2.6 General Principle in the Determination of Sensor Gauge Length. 3.2.7 Distributed Strain Sensor Measurement. 3.3 Interpretation of strain measurement. 3.3.1 Introduction. 3.3.2 Sources of Errors and Detection of Anomalous Structural Condition. 3.3.3 Determination of Strain Components and Stress from Total-Strain Measurement. 3.3.4 Example of Strain Measurement Interpretation. 4 Sensor Topologies: Monitoring Global Parameters. 4.1 Finite Element Structural Health Monitoring Concept: Introduction. 4.2 Simple Topology and Applications. 4.2.1 Basic Notions on Simple Topology. 4.2.2 Enchained Simple Topology. 4.2.3 Example of an Enchained Simple Topology Application. 4.2.4 Scattered Simple Topology. 4.2.5 Example of a Scattered Simple Topology Application. 4.3 Parallel Topology. 4.3.1 Basic Notions on Parallel Topology: Uniaxial Bending. 4.3.2 Basic Notions on Parallel Topology: Biaxial Bending. 4.3.3 Deformed Shape and Displacement Diagram. 4.3.4 Examples of Parallel Topology Application. 4.4 Crossed Topology. 4.4.1 Basic Notions on Crossed Topology: Planar Case. 4.4.2 Basic Notions on Crossed Topology: Spatial Case. 4.4.3 Example of a Crossed Topology Application. 4.5 Triangular Topology. 4.5.1 Basic Notions on Triangular Topology. 4.5.2 Scattered and Spread Triangular Topologies. 4.5.3 Monitoring of Planar Relative Movements Between Two Blocks. 4.5.4 Example of a Triangular Topology Application. 5 Finite Element Structural Health Monitoring Strategies and Application Examples. 5.1 Introduction. 5.2 Monitoring of Pile Foundations. 5.2.1 Monitoring the Pile. 5.2.2 Monitoring a Group of Piles. 5.2.3 Monitoring of Foundation Slab. 5.2.4 On-Site Example of Piles Monitoring. 5.3 Monitoring of Buildings. 5.3.1 Monitoring of Building Structural Members. 5.3.2 Monitoring of Columns. 5.3.3 Monitoring of Cores. 5.3.4 Monitoring of Frames, Slabs and Walls. 5.3.5 Monitoring of a Whole Building. 5.3.6 On-Site Example of Building Monitoring. 5.4 Monitoring of Bridges. 5.4.1 Introduction. 5.4.2 Monitoring of a Simple Beam. 5.4.3 On-Site Example of Monitoring of a Simple Beam. 5.4.4 Monitoring of a Continuous Girder. 5.4.5 On-Site Example of Monitoring of a Continuous Girder. 5.4.6 Monitoring of a Balanced Cantilever Bridge. 5.4.7 On-Site Example of Monitoring of a Balanced Cantilever Girder. 5.4.8 Monitoring of an Arch Bridge. 5.4.9 On-Site Example of Monitoring of an Arch Bridge. 5.4.10 Monitoring of a Cable-Stayed Bridge. 5.4.11 On-Site Example of Monitoring of a Cable-Stayed Bridge. 5.4.12 Monitoring of a Suspended Bridge. 5.4.13 Bridge Integrity Monitoring. 5.4.14 On-Site Example of Bridge Integrity Monitoring. 5.5 Monitoring of Dams. 5.5.1 Introduction. 5.5.2 Monitoring of an Arch Dam. 5.5.3 On-Site Examples on Monitoring of an Arch Dam. 5.5.4 Monitoring of a Gravity Dam. 5.5.5 On-Site Example of Monitoring a Gravity Dam. 5.5.6 Monitoring of a Dyke (Earth or Rockfill Dam). 5.5.7 On-Site Example of Monitoring a Dyke. 5.6 Monitoring of Tunnels. 5.6.1 Introduction. 5.6.2 Monitoring of Convergence. 5.6.3 On-Site Example of Monitoring of Convergence. 5.6.4 Monitoring of Strain and Deformation. 5.6.5 On-Site Example of Monitoring of Deformation. 5.6.6 Monitoring of Other Parameters and Tunnel Integrity Monitoring. 5.7 Monitoring of Heritage Structures. 5.7.1 Introduction. 5.7.2 Monitoring of San Vigilio Church, Gandria, Switzerland. 5.7.3 Monitoring of Royal Villa, Monza, Italy. 5.7.4 Monitoring of Bolshoi Moskvore

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/9780470517819

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 490

Metadata

Authors
Glišić, B., & Inaudi, D.
Venue
Wiley eBooks
Publisher
Wiley
Published
2007-10-26
OpenAlex
W384079936
Cited by
490
References
0
FWCI
6.17
Type
book
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fibre Optic Methods for Structural Health Monitoring. https://app.cochat.ai/papers/10.1002/9780470517819
The paper
Glišić, B., & Inaudi, D. (2007). Fibre Optic Methods for Structural Health Monitoring. Wiley eBooks. https://doi.org/10.1002/9780470517819

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.