Cited by 24Prosthetics and Rehabilitation RoboticsRobotic Mechanisms and DynamicsSoft Robotics and Applications

The DOI matches its Crossref record; its reference list is not available.

Kinematics and Dynamics of Wearable Robots

Forner‐Cordero, A., Pons, J. L., Turowska, E. A., Schiele, A., Baydal‐Bertomeu, J. M., Garrido, D., Mollá, F., Belda‐lois, J. M., Poveda, R., Barberá, R., Rocon, E.·2008·Wearable Robots

Abstract

This chapter contains sections titled: Introduction Robot mechanics: motion equations Human biomechanics Kinematic redundancy in exoskeleton systems Case Study: a biomimetic, kinematically compliant knee joint modelled by a four-bar linkage Case Study: design of a forearm pronation–supination joint in an upper limb exoskeleton Case Study: study of tremor characteristics based on a biomechanical model of the upper limb References

Overview

Integrity signals

Registry

Crossref · 10.1002/9780470987667.ch3

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The main functions of human ankle joints during walking are body weight support and propulsion.

    “This is because the main functions of human ankle joints during walking are body weight support and propulsion [42].”

Citations

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

Cited by 24

Metadata

Authors
Forner‐Cordero, A., Pons, J. L., Turowska, E. A., Schiele, A., Baydal‐Bertomeu, J. M., Garrido, D., Mollá, F., Belda‐lois, J. M., Poveda, R., Barberá, R., & Rocon, E.
Affiliations
  • Consejo Superior de Investigaciones Científicas (ES)
  • European Space Agency (FR)
  • Biomechanics Institute of Valencia (ES)
Venue
Wearable Robots
Publisher
Wiley
Published
2008-02-15
Pages
47-85
OpenAlex
W1490571058
Cited by
24
References
0
Citations by year
2024: 3 · 2023: 2 · 2022: 2 · 2019: 6 · 2018: 4 · 2017: 1 · 2015: 4 · 2013: 1 · 2012: 1
Type
other
Language
en
Open access
closed
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
wearable robotics, exoskeleton, robot kinematics, robot dynamics, human biomechanics, kinematic redundancy, four-bar linkage, knee joint model, forearm rotation, upper limb exoskeleton, tremor, biomechanical modeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review