The DOI matches its Crossref record; its reference list is not available.
Kinematics and Dynamics of Wearable Robots
Abstract
This chapter contains sections titled: Introduction Robot mechanics: motion equations Human biomechanics Kinematic redundancy in exoskeleton systems Case Study: a biomimetic, kinematically compliant knee joint modelled by a four-bar linkage Case Study: design of a forearm pronation–supination joint in an upper limb exoskeleton Case Study: study of tremor characteristics based on a biomechanical model of the upper limb References
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The main functions of human ankle joints during walking are body weight support and propulsion.
“This is because the main functions of human ankle joints during walking are body weight support and propulsion [42].”
From Recent developments and challenges of lower extremity exoskeletons (2016) · cites this paper as [42]
Citations
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
Cited by 24
Metadata
- Authors
- Forner‐Cordero, A., Pons, J. L., Turowska, E. A., Schiele, A., Baydal‐Bertomeu, J. M., Garrido, D., Mollá, F., Belda‐lois, J. M., Poveda, R., Barberá, R., & Rocon, E.
- Affiliations
- Consejo Superior de Investigaciones Científicas (ES)
- European Space Agency (FR)
- Biomechanics Institute of Valencia (ES)
- Venue
- Wearable Robots
- Publisher
- Wiley
- Published
- 2008-02-15
- Pages
- 47-85
- OpenAlex
- W1490571058
- Cited by
- 24
- References
- 0
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 2 · 2019: 6 · 2018: 4 · 2017: 1 · 2015: 4 · 2013: 1 · 2012: 1
- Type
- other
- Language
- en
- Open access
- closed
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Keywords
- wearable robotics, exoskeleton, robot kinematics, robot dynamics, human biomechanics, kinematic redundancy, four-bar linkage, knee joint model, forearm rotation, upper limb exoskeleton, tremor, biomechanical modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review