The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Inductively Coupled Plasma–Mass Spectrometry
Abstract
This chapter highlights the use of the inductively plasma for mass spectrometry, with the fundamentals of mass spectrometry. A range of mass spectrometers have been coupled to an inductively coupled plasma. However, the first to be exploited commercially was the quadrupole mass spectrometer. This was closely followed by the high-resolution mass spectrometer to overcome some of the deficiencies of a quadrupole mass spectrometer, that is, its inability to overcome interferences due to its low resolution; a quadrupole mass spectrometer being limited to unit-mass resolution. More recently, other mass spectrometers have been exploited, namely the triple quadrupole, ion-trap, time-of-flight and multiple collector mass spectrometers. As any mass spectrometer is capable of measuring isotope ratios (ratios of the different isotopes of a single element), isotope dilution analysis uses this approach to provide a unique method of calibration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
P, D. (1992) · Journal of Molecular Structure · doi:10.1016/0022-2860(92)85083-s · Cited by 9,329
Houk, R. S., Fassel, V. A., Flesch, G. D., Svec, H. J., Gray, A. L., & Taylor, C. E. (1980) · Analytical Chemistry · doi:10.1021/ac50064a012 · Cited by 766
Reaction cells and collision cells for ICP-MS: a tutorial review
Tanner, S. D., Baranov, V. I., & Bandura, D. R. (2002) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(02)00069-1 · Cited by 670
Use of single-collector and multi-collector ICP-mass spectrometry for isotopic analysis
Vanhaecke, F., Balcaen, L., & Malinovsky, D. (2009) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b903887f · Cited by 184
Rehkämper, M., Schönbächler, M., & Stirling, C. H. (2001) · Geostandards Newsletter · doi:10.1111/j.1751-908x.2001.tb00785.x · Cited by 168
Cited by
Terrestrial in situ cosmogenic nuclides: theory and application
Gosse, J. C., & Phillips, F. M. (2001) · Quaternary Science Reviews · doi:10.1016/s0277-3791(00)00171-2 · Cited by 2,051
Atmospheric pressure plasmas: A review
Tendero, C., Tixier, C., Tristant, P., Desmaison, J., & Leprince, P. (2006) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2005.10.003 · Cited by 1,553
Gas discharge plasmas and their applications
Bogaerts, A., Neyts, E., Gijbels, R., & van der Mullen, J. (2002) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/s0584-8547(01)00406-2 · Cited by 1,109
Understanding nanoparticle endocytosis to improve targeting strategies in nanomedicine
Sousa de Almeida, M., Susnik, E., Drasler, B., Taladriz-Blanco, P., Petri-Fink, A., & Rothen-Rutishauser, B. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01127d · Cited by 1,079
Modification and preservation of environmental signals in speleothems
Fairchild, I. J., Smith, C. L., Baker, A., Fuller, L., Spötl, C., Mattey, D., McDermott, F., & E.I.M.F. (2006) · Earth-Science Reviews · doi:10.1016/j.earscirev.2005.08.003 · Cited by 852
Metadata
- Venue
- Practical Inductively Coupled Plasma Spectrometry
- Publisher
- Wiley
- Published
- 2019-03-25
- Pages
- 133-176
- OpenAlex
- W653058417
- Cited by
- 956
- References
- 5
- Type
- other
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.