CoChat

Integration of sarcopenia screening into radiotherapy planning: Validation of a time‐efficient SMI measurement method using MIM software in prostate cancer

De Bruyn, Pauline, Coquelet, Nicolas, Ferreira, Paulo, Michel, Madeline, Descamps, Thomas, Van den Begin, Robbe, Van Gestel, Dirk, Preiser, Jean‐Charles · 2026 · Journal of Applied Clinical Medical Physics
Cited by 0

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Sarcopenia (SP) affects 43.8% of men with prostate cancer (PCa), correlating with higher all‐cause mortality and reduced quality of life. Systematic SP screening could reduce treatment complications and improve prognosis. Although several validated software tools exist for CT‐based skeletal muscle assessment, their implementation in routine clinical practice remains limited due to time constraints, operator dependency, and lack of integration into radiotherapy planning systems. Purpose: We aimed to validate a new SP screening method using MIM® software, a program commonly used in radiotherapy planning, to facilitate its implementation in daily practice. Methods: In 41 patients with PCa, Skeletal Muscle Index (SMI) was retrospectively calculated using MIM® and compared with the validated ImageJ® method. Agreement was assessed via Bland‐Altman analysis, while sarcopenic status was classified using literature‐based SMI thresholds. Measurement time and reproducibility were evaluated using Wilcoxon tests, Intraclass Correlation Coefficient (ICC), and Fleiss kappa coefficients (κ). Additionally, an automated MIM‐workflow was developed and compared to the semi‐manual MIM‐method in terms of agreement and processing time. Results: The cohort had a median age of 71 years, with 66% overweight or obese and 22% classified as sarcopenic. The new method demonstrated high concordance with the validated method (mean SMI difference: −0.04 cm 2 /m 2 , p = 0.23), while significantly reducing calculation time (3.5 ± 1 min vs. 10 ± 1 min, p < 0.001). Reproducibility was excellent, with an ICC of 0.99 for SMI and perfect agreement on sarcopenic classification ( κ = 1). The automated MIM‐workflow further decreased processing time (median 3.2 min vs. 3.5 min, p < 0.001) but yielded slightly higher SMI values (mean difference: 2.3 cm 2 /m 2 , p < 0.0001). Conclusion: MIM® software provides a reproducible, reliable, and time‐efficient alternative for SP screening, allowing radiation‐oncologists to implement this assessment immediately into routine radiotherapy planning. Although the automated MIM‐workflow requires further calibration to correct for systematic SMI overestimation, it represents a promising step toward full automation and broader clinical integration of SP assessment within radiation‐oncology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/acm2.70694

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 28

  1. 10.1016/j.jgo.2023.101594 · DOI
  2. 10.1080/01635581.2021.1884731 · DOI
  3. 10.1016/j.radonc.2024.110663 · DOI · Paper page
  4. 10.1200/JCO.2012.45.2722 · DOI · Paper page
  5. 10.1016/j.nut.2018.06.003 · DOI
  6. 10.1016/S1470‐2045(08)70153‐0 · DOI · Paper page
  7. 10.20945/2359‐3997000000174 · DOI
  8. 10.1097/SLA.0000000000000628 · DOI · Paper page
  9. 10.1038/oby.2007.573 · DOI · Paper page
  10. 10.2522/ptj.20110380 · DOI · Paper page
  11. 10.1002/jpen.1036 · DOI
  12. 10.1016/j.nut.2024.112421 · DOI
  13. 10.1007/s00261‐017‐1123‐6 · DOI
  14. 10.1186/s12880‐019‐0316‐6 · DOI
  15. 10.3390/diagnostics14151696 · DOI
  16. BlankemeierL DesaiA ChavesJMZ et al.Comp2Comp: open‐source body composition assessment on computed tomography. Published online February 13 2023.http://arxiv.org/abs/2302.06568
  17. 10.1038/s41598‐025‐96238‐6 · DOI
  18. 10.1148/ryai.230024 · DOI · Paper page
  19. 10.1007/s00223‐021‐00914‐4 · DOI
  20. 10.1002/jpen.1721 · DOI
  21. 10.1016/j.eururo.2020.09.042 · DOI · Paper page
  22. 10.5114/aoms/191297 · DOI
  23. 10.3390/healthcare14111476 · DOI
  24. 10.1007/s11547‐022‐01450‐3 · DOI · Paper page
  25. 10.1139/H08‐075 · DOI · Paper page
  26. 10.1016/S1470‐2045(10)70218‐7 · DOI · Paper page
  27. 10.1002/jcsm.13160 · DOI
  28. 10.1093/ageing/afr051 · DOI · Paper page

Metadata

Authors
De Bruyn, P., Coquelet, N., Ferreira, P., Michel, M., Descamps, T., Van den Begin, R., Van Gestel, D., & Preiser, J.
Venue
Journal of Applied Clinical Medical Physics
Publisher
Wiley
Published
2026-07
Volume
27
Issue
7
ISSN
1526-9914
Cited by
0
References
3
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.