The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Dielectric Elastomers in Actuator Technology
Abstract
Electroactive polymers (EAPs) are characterized by their ability to respond to external electric stimulation by displaying a significant shape or size displacement. Actuators, based on dielectric elastomers exhibiting low elastic stiffness and high dielectric constants, can produce high strain levels from 10 to 380 %. Typically, acrylic and silicone materials are used as dielectric layer in such actuators. Their potential to mimic the movement of animals, insects and even human body parts are increasingly of interest for researchers in the field of biomimetics, as well as more classical application fields like robotics. The control of the most important material properties, elastic moduli and dielectric constants of the dielectric elastomers and electrode materials, together with the control of fabrication parameters i.e. film thickness, electrode manufacturing as well as design of the actuator configuration allow the fabrication of tailor‐made actuators, which match the necessary requirements for a given application. Theoretical models contribute to a deeper understanding of EAP actuators and improve design and optimisation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AB-polymer networks based on oligo(ɛ-caprolactone) segments showing shape-memory properties
Lendlein, A., Schmidt, A. M., & Langer, R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.3.842 · Cited by 303
Cited by
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Method to analyze electromechanical stability of dielectric elastomers
Zhao, X., & Suo, Z. (2007) · Applied Physics Letters · doi:10.1063/1.2768641 · Cited by 470
Molberg, M., Crespy, D., Rupper, P., Nüesch, F., Månson, J. E., Löwe, C., & Opris, D. M. (2010) · Advanced Functional Materials · doi:10.1002/adfm.201000486 · Cited by 298
Self-citationLu, H.-F., Wang, M., Chen, X.-M., Lin, B.-P., & Yang, H. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b06757 · Cited by 287
Electroactive Polymers: Developments of and Perspectives for Dielectric Elastomers
Biggs, J., Danielmeier, K., Hitzbleck, J., Krause, J., Kridl, T., Nowak, S., Orselli, E., Quan, X., Schapeler, D., Sutherland, W., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301918 · Cited by 264
Metadata
- Authors
- Löwe, C., Zhang, X., & Kovacs, G.
- Venue
- Advanced Engineering Materials
- Publisher
- Wiley
- Published
- 2005-05
- Volume
- 7
- Issue
- 5
- Pages
- 361-367
- ISSN
- 1438-1656 (ISSN-L)
- 1527-2648
- OpenAlex
- W2162938508
- Cited by
- 178
- References
- 1
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dielectric Elastomers in Actuator Technology. https://app.cochat.ai/papers/10.1002/adem.200500066
- The paper
- Löwe, C., Zhang, X., & Kovacs, G. (2005). Dielectric Elastomers in Actuator Technology. Advanced Engineering Materials. https://doi.org/10.1002/adem.200500066
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.