The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Open accessAbstract
Gas detection and monitoring are essential due to their direct impact on human health, environment, and ecosystem. Chemiresistive sensors are one of the most used classes of sensors for monitoring and measurement of gases thanks to their ease of fabrication, customizability, mechanical flexibility, and fast response time. While chemiresistive sensors can offer good sensitivity and selectivity to a particular gas in a controlled environment with known interferences, they may not be able to differentiate between various gases having similar physiochemical properties under uncontrolled conditions. To address this shortcoming of chemiresistive gas sensors, sensor arrays have been the subject of recent studies. Gas sensor arrays are a group of individual gas sensors that are arranged to simultaneously detect and differentiate multiple cross‐reactive gases. In this regard, various sensor array technologies have been developed to differentiate a given set of gases using multivariate algorithms. This review provides an insight into the different algorithms that are used to extract the data from the sensor arrays, highlighting the fabrication techniques used for developing the sensor array prototypes, and different applications in which these arrays are used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of Urban Fine Particulate Matter
Zhang, R., Wang, G., Guo, S., Zamora, M. L., Ying, Q., Lin, Y., Wang, W., Hu, M., & Wang, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00067 · Cited by 1,426
Recent advances in energy-saving chemiresistive gas sensors: A review
Majhi, S. M., Mirzaei, A., Kim, H. W., Kim, S. S., & Kim, T. W. (2021) · Nano Energy · doi:10.1016/j.nanoen.2020.105369 · Cited by 653
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Flagged first, then by citations
Research works printed but not linked: 133
- 10.1016/j.bandc.2008.04.008 · DOI
- 10.1016/j.chest.2018.10.041 · DOI
- 10.4324/9780429470738 · DOI
- 10.3389/fpubh.2020.00014 · DOI · Paper page
- 10.1021/acssensors.7b00064 · DOI
- 10.1039/C5SC02632F · DOI
- 10.1021/acs.nanolett.6b05153 · DOI
- 10.1149/1945-7111/abf4ea · DOI
- 10.1021/acssensors.2c01086 · DOI
- 10.1002/adma.201806739 · DOI
- 10.1016/j.sna.2018.10.036 · DOI
- 10.1021/acsapm.9b00707 · DOI
- 10.1021/acssensors.9b00555 · DOI
- 10.1080/10408398.2020.1811635 · DOI
- 10.1016/j.snb.2019.126890 · DOI
- 10.1016/j.snb.2018.07.178 · DOI
- 10.1021/cr980102w · DOI
- 10.1021/ac60191a001 · DOI
- 10.1021/ac60240a031 · DOI
- 10.1063/1.1755123 · DOI
- 10.1021/ac00292a036 · DOI
- 10.1021/ac00127a037 · DOI
- 10.1016/0250-6874(89)87043-X · DOI
- 10.1021/ac00295a047 · DOI
- 10.1021/jf00004a027 · DOI
- 10.1039/an9931800379 · DOI
- 10.1016/S0925-4005(98)00227-5 · DOI
- 10.1016/S0003-2670(98)00780-6 · DOI
- 10.1016/j.snb.2005.03.116 · DOI
- 10.1016/j.snb.2005.02.017 · DOI
- 10.1021/jp064371z · DOI
- 10.1108/SR-07-2015-0115 · DOI
- 10.3390/s150100001 · DOI
- 10.3390/s141019700 · DOI
- 10.3390/chemosensors9060116 · DOI
- Colina J., 2000, A Review of the Ammonia Issue and Pork Production
- 10.1079/WPS20000018 · DOI
- 10.1002/advs.202002014 · DOI
- 10.1016/S0140-6736(08)61421-X · DOI
- 10.1016/j.snb.2016.04.165 · DOI
- 10.1016/j.snb.2017.11.166 · DOI
- 10.1016/j.snb.2019.126689 · DOI
- 10.1016/j.snb.2019.01.044 · DOI
- 10.3390/chemosensors9080201 · DOI
- 10.1016/j.jcis.2021.08.022 · DOI
- 10.1149/1945-7111/ab67a6 · DOI
- 10.1016/S0140-6736(98)07552-7 · DOI
- 10.1088/1752-7155/8/2/027112 · DOI
- 10.1021/ac970427x · DOI
- 10.1016/S0925-4005(99)00153-7 · DOI
- 10.3390/s16020181 · DOI
- Stoller A., 1970, RCA Rev., 31, 265
- 10.1002/ange.201907772 · DOI
- 10.1007/s12274-020-2823-8 · DOI
- 10.1039/C8NR04198A · DOI
- 10.1021/acsami.9b04385 · DOI
- 10.1002/smll.201602868 · DOI
- 10.1002/oby.21242 · DOI
- 10.1002/adma.201400334 · DOI
- 10.1016/j.orgel.2018.12.035 · DOI
- 10.3390/s16081163 · DOI
- 10.1016/j.snr.2020.100011 · DOI
- 10.3390/chemosensors10020068 · DOI
- 10.1016/j.snb.2016.08.085 · DOI
- 10.1002/smll.201902065 · DOI
- 10.1109/JSEN.2018.2811461 · DOI
- 10.1021/acsami.0c00720 · DOI
- 10.1016/j.biosx.2019.100016 · DOI
- 10.1021/acsami.6b03256 · DOI
- 10.1186/s40486-021-00136-1 · DOI
- 10.1038/s41427-019-0187-x · DOI
- 10.1007/s12274-017-1661-9 · DOI
- 10.1016/j.matt.2021.06.009 · DOI
- 10.1016/j.ifset.2017.08.003 · DOI
- 10.1016/j.matchemphys.2018.06.056 · DOI
- 10.1016/j.talanta.2017.08.024 · DOI
- 10.1021/acssensors.6b00829 · DOI
- 10.1016/j.snb.2018.04.078 · DOI
- 10.1021/acssensors.9b00825 · DOI
- 10.3390/s151127804 · DOI
- 10.1016/B978-044451980-1.50009-4 · DOI
- 10.1002/9781118887486 · DOI
- Li L., 2019, Principal Component Analysis for Dimensionality Reduction
- 10.1007/978-3-642-04898-2_395 · DOI · Paper page
- 10.1039/c3cs60179j · DOI
- Raschka S., 2015, Principal Component Analysis in 3 Simple Steps, 2016
- 10.1109/JSEN.2020.2972542 · DOI
- 10.1063/1.5063375 · DOI
- 10.3390/s17071662 · DOI
- 10.1021/acs.chemrev.8b00226 · DOI
- 10.1038/nbt1206-1565 · DOI
- 10.7551/mitpress/4175.001.0001 · DOI
- Y.Fan D.Shen C.Davatzikos inInt. Conf. Medical Image Computing and Computer-Assisted Intervention Springer Palm Springs CA USA October 26–292005 https://link.springer.com/book/10.1007/11566465. · DOI
- 10.1007/s11548-011-0643-8 · DOI
- 10.3390/s20010117 · DOI
- 10.1016/j.snb.2004.05.043 · DOI
- Maind S. B., 2014, Int. J. Recent Innovation Trends Comput. Commun., 2, 96
- 10.1016/j.snb.2008.05.016 · DOI
- 10.1016/j.snb.2007.08.044 · DOI
- 10.1016/0021-9673(94)80518-0 · DOI
- 10.1016/S0140-6736(95)90726-2 · DOI
- 10.1016/j.talanta.2006.10.046 · DOI
- 10.1016/j.bios.2006.10.027 · DOI
- 10.1016/j.snb.2007.02.002 · DOI
- 10.1016/j.snb.2006.09.013 · DOI
- 10.1063/10.0009664 · DOI
- 10.5194/acp-18-4171-2018 · DOI
- M.Stranzenbach B.Saruhan inTransducers 2007-2007 Int. Solid-State Sensors Actuators and Microsystems Conf. IEEE Piscataway NJ2007.
- 10.1039/C6CP07799D · DOI
- 10.1016/j.spmi.2014.03.040 · DOI
- 10.1021/acsnano.5b04343 · DOI
- 10.1039/C6TA11019C · DOI
- N.Tayebi V.Kollia P. S.Singh arXiv preprint arXiv:2102.12990 2021. · arXiv
- 10.1016/S0720-048X(02)00286-3 · DOI
- 10.1038/299352a0 · DOI
- 10.1021/cr300174a · DOI · Paper page
- 10.3390/diagnostics12020430 · DOI
- Chimwamurombe P. M., 2020, Agric. Food Sci. Res., 7, 105
- 10.3390/jfb12040067 · DOI
- 10.1007/s13197-021-05280-5 · DOI
- Tuan S.-J., 2009, J. Food Drug Anal., 17, 8
- 10.1016/B978-0-12-821292-9.00010-8 · DOI
- 10.1016/j.lwt.2015.11.034 · DOI
- 10.1016/j.jfoodeng.2016.01.016 · DOI
- 10.3390/s90705099 · DOI
- 10.1094/9780890546383 · DOI
- 10.1002/adfm.201906711 · DOI
- 10.1039/C4RA07560A · DOI
- 10.1016/j.jhazmat.2021.127524 · DOI
- 10.1016/j.snb.2021.130134 · DOI
- 10.1016/j.snb.2022.131424 · DOI
- 10.1016/j.snb.2021.131066 · DOI
- 10.1002/admt.202101486 · DOI
Metadata
- Authors
- Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S.
- Affiliations
- The University of Sydney (AU)
- Corresponding author
- Farajikhah, Syamak
- Venue
- Advanced Engineering Materials
- Publisher
- Wiley
- Published
- 2022-12
- Volume
- 25
- Issue
- 3
- ISSN
- 1438-1656 (ISSN-L)
- 1527-2648
- OpenAlex
- W4308934377
- Cited by
- 183
- References
- 3
- Citations by year
- 2026: 34 · 2025: 75 · 2024: 54 · 2023: 20
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Advanced Engineering Materials (publishedVersion, cc-by-nc)
- Funders
- Australian Research Council (LP180100309)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
- Keywords
- chemiresistive gas sensors, gas sensor arrays, volatile organic compounds, gas sensing, gas discrimination, sensor selectivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review