CoChat

A Raman Spectroscopy Study of Individual SiC Nanowires

Bechelany, M., Brioude, A., Cornu, D., Ferro, G., Miele, P. · 2007 · Advanced Functional Materials
Cited by 199

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Raman spectroscopy of a single 40 nm 3C‐SiC nanowire (NW) has been achieved at room temperature with the use of surface‐enhanced Raman scattering (SERS). The structure used to enhance the Raman scattering process is based on a tungsten tip covered by a thin gold layer; a NW is attached to the apex of this tip. The specific dimensions of the SiC NWs (diameters are a few tens of nanometers and lengths are a few micrometers) allow us to study several parts of an individual NW according to the lateral resolution of the Raman microspectrometer. High‐resolution transmission electron microscopy (HRTEM) images show both atomic arrangements in the SiC NWs with growth predominantly in the [111] direction and abundant structural defects. Effort has been focused on the correlation between the Raman spectroscopic profiles and the structural deformations. The Fano interference features of the sharp phonon lines have been used to evaluate the free carrier concentration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.200600816

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Research works printed but not linked: 19

  1. 10.1016/S0009-2614(00)01145-3 · doi:10.1016/s0009-2614(00)01145-3
  2. 10.1007/s00339-002-1961-z · doi:10.1007/s00339-002-1961-z
  3. 10.1126/science.281.5379.973 · DOI
  4. 10.1016/S0009-2614(02)01527-0 · doi:10.1016/s0009-2614(02)01527-0
  5. 10.1039/b308164h · doi:10.1039/b308164h
  6. 10.1016/S0038-1098(02)00408-8 · doi:10.1016/s0038-1098(02)00408-8
  7. 10.1002/9780470291283.ch36 · doi:10.1002/9780470291283.ch36
  8. Bechelany M., 2006, J. Opt. Adv. Mater., 8, 638
  9. 10.1088/0953-8984/17/15/010 · doi:10.1088/0953-8984/17/15/010
  10. 10.1016/S0038-1098(99)00262-8 · doi:10.1016/s0038-1098(99)00262-8
  11. 10.1103/PhysRevB.58.9858 · doi:10.1103/physrevb.58.9858
  12. 10.1016/S0038-1098(03)00236-9 · doi:10.1016/s0038-1098(03)00236-9
  13. 10.1021/nl0341133 · doi:10.1021/nl0341133
  14. 10.1103/PhysRevB.6.498 · doi:10.1103/physrevb.6.498
  15. 10.4028/www.scientific.net/MSF.338-342.603 · doi:10.4028/www.scientific.net/msf.338-342.603
  16. 10.1063/1.338830 · doi:10.1063/1.338830
  17. 10.1016/S0009-2614(00)01189-1 · doi:10.1016/s0009-2614(00)01189-1
  18. 10.1016/S0169-4332(03)00891-2 · doi:10.1016/s0169-4332(03)00891-2
  19. 10.1103/PhysRevLett.88.105502 · doi:10.1103/physrevlett.88.105502

Cited by

See all 199

Metadata

Authors
Bechelany, M., Brioude, A., Cornu, D., Ferro, G., & Miele, P.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2007-03-02
Volume
17
Issue
6
Pages
939-943
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2146969501
Cited by
199
References
10
FWCI
5.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Raman Spectroscopy Study of Individual SiC Nanowires. https://app.cochat.ai/papers/10.1002/adfm.200600816
The paper
Bechelany, M., Brioude, A., Cornu, D., Ferro, G., & Miele, P. (2007). A Raman Spectroscopy Study of Individual SiC Nanowires. Advanced Functional Materials. https://doi.org/10.1002/adfm.200600816

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.