Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 175

The DOI matches its Crossref record.

A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces

Stich, Matthias I. J., Nagl, Stefan, Wolfbeis, Otto S., Henne, Ulrich, Schaeferling, Michael·2008·Advanced Functional Materials

Abstract

A novel kind of composite material for simultaneous luminescent determination of air pressure and temperature is presented. The dual sensor consists of a fluorinated platinum porphyrin complex (PtTFPP) as an oxygen‐sensitive probe, and of the highly temperature‐sensitive europium complex Eu(tta)3(dpbt) as temperature probe. Both are incorporated into different polymer microparticles to control response characteristics and to avoid interferences. Encapsulation of PtTFPP in poly(styrene‐co‐acrylonitrile) (PSAN) results in a broad dynamic range from 0.05 to 2.00 bar for pressure measurements. The europium complex was incorporated into poly(vinyl chloride) to reduce the cross sensitivity towards oxygen. This system represents a new class of luminescent sensor system, where the signals are separated via the different luminescence lifetimes of the indicators. It is possible to monitor the emission of the temperature‐sensitive probe by means of time‐resolved fluorescence imaging without interferences, because the luminescence lifetime of the temperature indicator is tenfold longer than that of the oxygen indicator. The temperature image can then be used to compensate cross sensitivity of the pressure indicator towards temperature. In combination with an appropriate time‐resolved measurement technique, this material enables simultaneous imaging of pressure (or oxygen partial pressure) and temperature distributions on surfaces. It is distinguished from other approaches of dual pressure and temperature sensitive paints because it avoids the need of signal separation by application of different cameras or by use of different optical filters or light sources.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.200701199

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 175

Metadata

Authors
Stich, M. I. J., Nagl, S., Wolfbeis, O. S., Henne, U., & Schaeferling, M.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2008-05-09
Volume
18
Issue
9
Pages
1399-1406
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2005795745
Cited by
175
References
0
FWCI
10.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces. https://app.cochat.ai/papers/10.1002/adfm.200701199
The paper
Stich, M. I. J., Nagl, S., Wolfbeis, O. S., Henne, U., & Schaeferling, M. (2008). A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces. Advanced Functional Materials. https://doi.org/10.1002/adfm.200701199

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.