The DOI matches its Crossref record.
A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces
Abstract
A novel kind of composite material for simultaneous luminescent determination of air pressure and temperature is presented. The dual sensor consists of a fluorinated platinum porphyrin complex (PtTFPP) as an oxygen‐sensitive probe, and of the highly temperature‐sensitive europium complex Eu(tta)3(dpbt) as temperature probe. Both are incorporated into different polymer microparticles to control response characteristics and to avoid interferences. Encapsulation of PtTFPP in poly(styrene‐co‐acrylonitrile) (PSAN) results in a broad dynamic range from 0.05 to 2.00 bar for pressure measurements. The europium complex was incorporated into poly(vinyl chloride) to reduce the cross sensitivity towards oxygen. This system represents a new class of luminescent sensor system, where the signals are separated via the different luminescence lifetimes of the indicators. It is possible to monitor the emission of the temperature‐sensitive probe by means of time‐resolved fluorescence imaging without interferences, because the luminescence lifetime of the temperature indicator is tenfold longer than that of the oxygen indicator. The temperature image can then be used to compensate cross sensitivity of the pressure indicator towards temperature. In combination with an appropriate time‐resolved measurement technique, this material enables simultaneous imaging of pressure (or oxygen partial pressure) and temperature distributions on surfaces. It is distinguished from other approaches of dual pressure and temperature sensitive paints because it avoids the need of signal separation by application of different cameras or by use of different optical filters or light sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Luminescent probes and sensors for temperature
Wang, X.-D., Wolfbeis, O. S., & Meier, R. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60102a · Cited by 1,647
Self-citationThe Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Metadata
- Authors
- Stich, M. I. J., Nagl, S., Wolfbeis, O. S., Henne, U., & Schaeferling, M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2008-05-09
- Volume
- 18
- Issue
- 9
- Pages
- 1399-1406
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2005795745
- Cited by
- 175
- References
- 0
- FWCI
- 10.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces. https://app.cochat.ai/papers/10.1002/adfm.200701199
- The paper
- Stich, M. I. J., Nagl, S., Wolfbeis, O. S., Henne, U., & Schaeferling, M. (2008). A Dual Luminescent Sensor Material for Simultaneous Imaging of Pressure and Temperature on Surfaces. Advanced Functional Materials. https://doi.org/10.1002/adfm.200701199
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.