The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Highly Sensitive Glucose Biosensors Based on Organic Electrochemical Transistors Using Platinum Gate Electrodes Modified with Enzyme and Nanomaterials
Abstract
Organic electrochemical transistors with glucose oxidase‐modified Pt gate electrodes are successfully used as highly sensitive glucose sensors. The gate electrodes are modified with nanomaterials (multi‐wall carbon nanotubes or Pt nanoparticles) for the first time, which results in a dramatic improvement in the sensitivity of the devices. The detection limit of the device modified with Pt nanoparticles on the gate electrode is about 5 nM, which is three orders of magnitude better than a device without the nanoparticles. The improvement of the device performance can be attributed to the excellent electrocatalytic properties of the nanomaterials and more effective immobilization of enzyme on the gate electrodes. Based on the same principle, many other types of enzyme sensors with high sensitivity and low cost are expected to be realized by modifying the gate electrodes of organic electrochemical transistors with specific enzymes and nanomaterials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon Nanotubes--the Route Toward Applications
Baughman, R. H., Zakhidov, A. A., & de Heer, W. A. (2002) · Science · doi:10.1126/science.1060928 · Cited by 10,267
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
High-Resolution Inkjet Printing of All-Polymer Transistor Circuits
Sirringhaus, H., Kawase, T., Friend, R. H., Shimoda, T., Inbasekaran, M., Wu, W., & Woo, E. P. (2000) · Science · doi:10.1126/science.290.5499.2123 · Cited by 3,311
Efficient Tandem Polymer Solar Cells Fabricated by All-Solution Processing
Kim, J. Y., Lee, K., Coates, N. E., Moses, D., Nguyen, T.-Q., Dante, M., & Heeger, A. J. (2007) · Science · doi:10.1126/science.1141711 · Cited by 3,270
Electrochemical Biosensing Platforms Using Platinum Nanoparticles and Carbon Nanotubes
Hrapovic, S., Liu, Y., Male, K. B., & Luong, J. H. T. (2004) · Analytical Chemistry · doi:10.1021/ac035143t · Cited by 1,064
Gooding, J. J. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2004.08.052 · Cited by 1,060
Steady‐State and Transient Behavior of Organic Electrochemical Transistors
Bernards, D. A., & Malliaras, G. G. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601239 · Cited by 997
Biomolecule‐Functionalized Carbon Nanotubes: Applications in Nanobioelectronics
Katz, E., & Willner, I. (2004) · ChemPhysChem · doi:10.1002/cphc.200400193 · Cited by 749
Carbon Nanotube−Chitosan System for Electrochemical Sensing Based on Dehydrogenase Enzymes
Zhang, M., Smith, A., & Górski, W. (2004) · Analytical Chemistry · doi:10.1021/ac049519u · Cited by 696
White, H. S., Kittlesen, G. P., & Wrighton, M. S. (1984) · Journal of the American Chemical Society · doi:10.1021/ja00330a070 · Cited by 634
Berggren, M., & Richter‐Dahlfors, A. (2007) · Advanced Materials · doi:10.1002/adma.200700419 · Cited by 630
Huang, J., Miller, P. F., Wilson, J. S., de Mello, A. J., de Mello, J. C., & Bradley, D. D. C. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400073 · Cited by 517
Chemical and biological sensors based on organic thin-film transistors
Mabeck, J. T., & Malliaras, G. G. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3390-2 · Cited by 479
Enzymatic sensing with organic electrochemical transistors
Bernards, D. A., Macaya, D. J., Nikolou, M., DeFranco, J. A., Takamatsu, S., & Malliaras, G. G. (2008) · J. Mater. Chem. · doi:10.1039/b713122d · Cited by 410
Wang, J., Kawde, A.-N., & Musameh, M. (2003) · The Analyst · doi:10.1039/b303282e · Cited by 312
The Application of Organic Electrochemical Transistors in Cell‐Based Biosensors
Lin, P., Yan, F., Yu, J., Chan, H. L. W., & Yang, M. (2010) · Advanced Materials · doi:10.1002/adma.201000971 · Cited by 299
Self-citationChemical and Physical Sensing by Organic Field‐Effect Transistors and Related Devices
Someya, T., Dodabalapur, A., Huang, J., See, K. C., & Katz, H. E. (2010) · Advanced Materials · doi:10.1002/adma.200902760 · Cited by 296
Tang, H., Chen, J., Yao, S., Nie, L., Deng, G., & Kuang, Y. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2004.05.005 · Cited by 282
Self-citationNilsson, D. (2002) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00170-3 · Cited by 247
Zhu, Z., Mabeck, J. T., Zhu, C., Cady, N. C., Batt, C. A., & Malliaras, G. G. (2004) · Chemical Communications · doi:10.1039/b403327m · Cited by 222
Influence of Device Geometry on Sensor Characteristics of Planar Organic Electrochemical Transistors
Cicoira, F., Sessolo, M., Yaghmazadeh, O., DeFranco, J. A., Yang, S. Y., & Malliaras, G. G. (2010) · Advanced Materials · doi:10.1002/adma.200902329 · Cited by 197
In Situ, Label‐Free DNA Detection Using Organic Transistor Sensors
Khan, H. U., Roberts, M. E., Johnson, O., Förch, R., Knoll, W., & Bao, Z. (2010) · Advanced Materials · doi:10.1002/adma.201000790 · Cited by 185
Simple glucose sensors with micromolar sensitivity based on organic electrochemical transistors
Macaya, D. J., Nikolou, M., Takamatsu, S., Mabeck, J. T., Owens, R. M., & Malliaras, G. G. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.038 · Cited by 161
Field effect detection of biomolecular interactions
Estrela, P., Stewart, A., Yan, F., & Migliorato, P. (2005) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.075 · Cited by 92
Self-citationTang, H., Yan, F., Tai, Q., & Chan, H. L. W. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.11.027 · Cited by 92
Self-citationOne Step Fabrication of Microbiosensor Prepared by the Codeposition of Enzyme and Platinum Particles
Ikariyama, Y., Yamauchi, S., Yukiashi, T., & Ushioda, H. (1987) · Analytical Letters · doi:10.1080/00032718708082596 · Cited by 77
Improvement of the Tunable Wettability Property of Poly(3-alkylthiophene) Films
Lin, P., Yan, F., & Chan, H. L. W. (2009) · Langmuir · doi:10.1021/la900387m · Cited by 44
Self-citationKim, Y., Do, J., Kim, J., Yang, S. Y., Malliaras, G. G., Ober, C. K., & Kim, E. (2010) · Japanese Journal of Applied Physics · doi:10.1143/jjap.49.01ae10 · Cited by 35
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
PEDOT:PSS for Flexible and Stretchable Electronics: Modifications, Strategies, and Applications
Fan, X., Nie, W., Tsai, H., Wang, N., Huang, H., Cheng, Y., Wen, R., Ma, L., Yan, F., & Xia, Y. (2019) · Advanced Science · doi:10.1002/advs.201900813 · Cited by 1,028
Self-citationOrganic Thin‐Film Transistors for Chemical and Biological Sensing
Lin, P., & Yan, F. (2012) · Advanced Materials · doi:10.1002/adma.201103334 · Cited by 907
Self-citationDevice integration of electrochemical biosensors
Wu, J., Liu, H., Chen, W., Ma, B., & Ju, H. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00032-w · Cited by 895
High-performance transistors for bioelectronics through tuning of channel thickness
Rivnay, J., Leleux, P., Ferro, M., Sessolo, M., Williamson, A., Koutsouras, D. A., Khodagholy, D., Ramuz, M., Strakosas, X., Owens, R. M., et al. (2015) · Science Advances · doi:10.1126/sciadv.1400251 · Cited by 728
Metadata
- Authors
- Tang, H., Yan, F., Lin, P., Xu, J., & Chan, H. L. W.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2011-04-26
- Volume
- 21
- Issue
- 12
- Pages
- 2264-2272
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2076501420
- Cited by
- 310
- References
- 28
- FWCI
- 9.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.