The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Luminescent Metal‐Organic Frameworks for Selectively Sensing Nitric Oxide in an Aqueous Solution and in Living Cells
Abstract
Cu 2+‐based metal‐organic framework (Cu−TCA) (H 3TCA = tricarboxytriphenyl amine) having triphenylamine emitters was assembled and structurally characterized. Cu−TCA features a three‐dimensional porous structure consolidated by the well‐established Cu 2(O 2 CR)4 paddlewheel units with volume of the cavities approximately 4000 nm 3. Having paramagnetic Cu 2+ ions to quench the luminescence of triphenylamine, Cu−TCA only exhibited very weak emission at 430 nm; upon the addition of NO up to 0.1 m M, the luminescence was recovered directly and provided about 700‐fold fluorescent enhancement. The luminescence detection exhibited high selectivity – other reactive species present in biological systems, including H 2 O 2, NO 3−, NO 2−, ONOO−, ClO− and 1 O 2, did not interfere with the NO detection. The brightness of the emission of Cu−TCA also led to its successful application in the biological imaging of NO in living cells. As a comparison, lanthanide metal‐organic framework Eu−TCA having triphenylamine emitters and characteristic europium emitters was also assembled. Eu−TCA exhibited ratiometric fluorescent responses towards NO with the europium luminescence maintained as the internal standard and the triphenylamine emission exhibited more than 1000‐fold enhancement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horike, S., Shimomura, S., & Kitagawa, S. (2009) · Nature Chemistry · doi:10.1038/nchem.444 · Cited by 2,486
BioMOFs: Metal–Organic Frameworks for Biological and Medical Applications
McKinlay, A. C., Morris, R. E., Horcajada, P., Férey, G., Gref, R., Couvreur, P., & Serre, C. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000048 · Cited by 1,256
Cited by
Luminescent metal–organic frameworks for chemical sensing and explosive detection
Hu, Z., Deibert, B. J., & Li, J. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00010b · Cited by 4,169
Metal–organic frameworks: functional luminescent and photonic materials for sensing applications
Lustig, W. P., Mukherjee, S., Rudd, N. D., Desai, A. V., Li, J., & Ghosh, S. K. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00930a · Cited by 3,050
Improving MOF stability: approaches and applications
Ding, M., Cai, X., & Jiang, H.-L. (2019) · Chemical Science · doi:10.1039/c9sc03916c · Cited by 1,666
He, C., Liu, D., & Lin, W. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00125 · Cited by 1,001
Self-citationChemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Metadata
- Authors
- Wu, P., Wang, J., He, C., Zhang, X., Wang, Y., Liu, T., & Duan, C.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2012-02-06
- Volume
- 22
- Issue
- 8
- Pages
- 1698-1703
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2079870170
- Cited by
- 221
- References
- 2
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.