Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Single‐Step Deposition of Au‐ and Pt‐Nanoparticle‐Functionalized Tungsten Oxide Nanoneedles Synthesized Via Aerosol‐Assisted CVD, and Used for Fabrication of Selective Gas Microsensor Arrays

Open access
Vallejos, Stella, Umek, Polona, Stoycheva, Toni, Annanouch, Fatima, Llobet, Eduard, Correig, Xavier, De Marco, Patrizia, Bittencourt, Carla, Blackman, Chris·2013·Advanced Functional Materials

Abstract

Tungsten oxide nanostructures functionalized with gold or platinum NPs are synthesized and integrated, using a single‐step method via aerosol‐assisted chemical vapour deposition, onto micro‐electromechanical system (MEMS)‐based gas‐sensor platforms. This co‐deposition method is demonstrated to be an effective route to incorporate metal nanoparticles (NP) or combinations of metal NPs into nanostructured materials, resulting in an attractive way of tuning functionality in metal oxides (MOX). The results show variations in electronic and sensing properties of tungsten oxide according to the metal NPs introduced, which are used to discriminate effectively analytes (C 2 H 5 OH, H 2, and CO) that are present in proton‐exchange fuel cells. Improved sensing characteristics, in particular to H 2, are observed at 250 °C with Pt‐functionalized tungsten oxide films, whereas non‐functionalized tungsten oxide films show responses to low concentrations of CO at low temperatures. Differences in the sensing characteristics of these films are attributed to the different reactivities of metal NPs (Au and Pt), and to the degree of electronic interaction at the MOX/metal NP interface. The method presented in this work has advantages over other methods of integrating nanomaterials and devices, of having fewer processing steps, relatively low processing temperature, and no requirement for substrate pre‐treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201201871

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 163

Metadata

Authors
Vallejos, S., Umek, P., Stoycheva, T., Annanouch, F., Llobet, E., Correig, X., De Marco, P., Bittencourt, C., & Blackman, C.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2012-10-15
Volume
23
Issue
10
Pages
1313-1322
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2071099872
Cited by
163
References
1
FWCI
8.34
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Single‐Step Deposition of Au‐ and Pt‐Nanoparticle‐Functionalized Tungsten Oxide Nanoneedles Synthesized Via Aerosol‐Assisted CVD, and Used for Fabrication of Selective Gas Microsensor Arrays. https://app.cochat.ai/papers/10.1002/adfm.201201871
The paper
Vallejos, S., Umek, P., Stoycheva, T., Annanouch, F., Llobet, E., Correig, X., De Marco, P., Bittencourt, C., & Blackman, C. (2013). Single‐Step Deposition of Au‐ and Pt‐Nanoparticle‐Functionalized Tungsten Oxide Nanoneedles Synthesized Via Aerosol‐Assisted CVD, and Used for Fabrication of Selective Gas Microsensor Arrays. Advanced Functional Materials. https://doi.org/10.1002/adfm.201201871

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.