Multilayered Blood Capillary Analogs in Biodegradable Hydrogels for In Vitro Drug Permeability Assays
The DOI matches its Crossref record.
Abstract
Blood capillaries are crucial for the biological evaluation of drug diffusion to target tissues, and the penetration of cancer cells or viruses. Since most capillaries have a bilayered structure consisting of a monolayer of endothelial cells (ECs) and surrounding smooth muscle cells (SMCs), the in vitro reconstruction of this bilayered structure is a key challenge for pharmaceutical and biomedical applications. Here, a unique technology to construct size, length, orientation, and layer‐number controllable blood capillary networks in biodegradable hydrogels is reported. Uniaxial microchannels are prepared inside biodegradable hydrogels by the simple extraction of silica capillary tubes. The channel size, length, and distance of the uniaxial channels are easily controlled by altering these parameters of the silica tubes. The inner surfaces of the channels are successfully covered by bilayered structures consisting of ECs and SMCs by a hierarchical cell manipulation technique. Notably, serum albumin, which has an approximately 8 nm size, cannot penetrate this capillary wall during several hours of incubation due to the high blood vessel wall barrier property. This suggests a successful reconstruction of multilayered blood capillary networks possessing similar barrier function as native blood capillaries. Moreover, these capillary networks can be completely collected by the selective degradation of the surrounding hydrogels. This technique will be an innovative and versatile approach for in vitro permeability assays of drugs, drug delivery carriers, and cancer cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Vascularization and Angiogenesis in Tissue Engineering: Beyond Creating Static Networks
Rouwkema, J., & Khademhosseini, A. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.03.002 · Cited by 651
Organ-on-a chip systems: microengineering to biomimic living systems
Zheng, F., Fu, F., Cheng, Y., Wang, C., Zhao, Y., & Gu, Z. (2016) · Small · doi:10.1002/smll.201503208 · Cited by 338
Vascularized organoids on a chip: strategies for engineering organoids with functional vasculature
Zhang, S., Wan, Z., & Kamm, R. D. (2021) · Lab on a Chip · doi:10.1039/d0lc01186j · Cited by 316
Polyelectrolyte multilayered assemblies in biomedical technologies
Costa, R. R., & Mano, J. F. (2014) · Chemical Society Reviews · doi:10.1039/c3cs60393h · Cited by 296
Metadata
- Authors
- Yoshida, H., Matsusaki, M., & Akashi, M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2012-11-02
- Volume
- 23
- Issue
- 14
- Pages
- 1736-1742
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2022948076
- Cited by
- 61
- References
- 0
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multilayered Blood Capillary Analogs in Biodegradable Hydrogels for In Vitro Drug Permeability Assays. https://app.cochat.ai/papers/10.1002/adfm.201201905
- The paper
- Yoshida, H., Matsusaki, M., & Akashi, M. (2013). Multilayered Blood Capillary Analogs in Biodegradable Hydrogels for In Vitro Drug Permeability Assays. Advanced Functional Materials. https://doi.org/10.1002/adfm.201201905
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.