The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Tenogenic Induction of Human MSCs by Anisotropically Aligned Collagen Biotextiles
Open accessAbstract
A novel biofabrication modality, electrophoretic compaction with macromolecular alignment, is utilized to make collagen threads that mimic the native tendon's structure and mechanical properties. A device with kinematic electrodes is designed to fabricate collagen threads in continuous length. For the first time, a 3D‐biotextile is woven purely from collagen. Mechanical properties and load‐displacement behavior of the biotextile mimic those of the native tendon while presenting a porosity of 80%. The open pore network facilitates cell seeding across the continuum of the bioscaffold. Mesenchymal stem cells (MSCs) seeded in the woven scaffold undergo tenogenic differentiation in the absence of growth factors and synthesize a matrix that is positive for tenomodulin, COMP and type I collagen. Up‐regulation of tenomodulin, a tendon specific marker, is 11.6 ± 3.5 fold, COMP is up‐regulated 16.7 ± 5.5 fold, and Col I is up‐regulated 6.9 ± 2.7 fold greater on ELAC threads when compared to randomly oriented collagen gels. These results demonstrate that a bioscaffold woven using collagen threads with densely compacted and anisotropically aligned substrate texture stimulates tenogenesis topographically, rendering the electrochemically aligned collagen as a promising candidate for functional repair of tendons and ligaments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Host response to tissue engineered devices
Babensee, J. E., Anderson, J. M., McIntire, L. V., & Mikos, A. G. (1998) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(98)00023-4 · Cited by 585
Self-citationXu, H., Wan, H., Sandor, M., Qi, S., Ervin, F., Harper, J. R., Silverman, R. P., & McQuillan, D. J. (2008) · Tissue Engineering Part A · doi:10.1089/ten.tea.2007.0316 · Cited by 160
Cited by
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Li, Y., Xiao, Y., & Liu, C. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00654 · Cited by 598
Emerging Biofabrication Strategies for Engineering Complex Tissue Constructs
Pedde, R. D., Mirani, B., Navaei, A., Styan, T., Wong, S., Mehrali, M., Thakur, A., Mohtaram, N. K., Bayati, A., Dolatshahi‐Pirouz, A., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606061 · Cited by 388
Electrospun Fibrous Architectures for Drug Delivery, Tissue Engineering and Cancer Therapy
Ding, Y., Li, W., Zhang, F., Liu, Z., Zanjanizadeh Ezazi, N., Liu, D., & Santos, H. A. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201802852 · Cited by 312
Biodegradable Polymers as the Pivotal Player in the Design of Tissue Engineering Scaffolds
Zhang, F., & King, M. W. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901358 · Cited by 309
Metadata
- Authors
- Younesi, M., Islam, A., Kishore, V., Anderson, J. M., & Akkus, O.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2014-07-17
- Volume
- 24
- Issue
- 36
- Pages
- 5762-5770
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2154864006
- Cited by
- 179
- References
- 3
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tenogenic Induction of Human MSCs by Anisotropically Aligned Collagen Biotextiles. https://app.cochat.ai/papers/10.1002/adfm.201400828
- The paper
- Younesi, M., Islam, A., Kishore, V., Anderson, J. M., & Akkus, O. (2014). Tenogenic Induction of Human MSCs by Anisotropically Aligned Collagen Biotextiles. Advanced Functional Materials. https://doi.org/10.1002/adfm.201400828
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.