The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High Performance Three‐Dimensional Chemical Sensor Platform Using Reduced Graphene Oxide Formed on High Aspect‐Ratio Micro‐Pillars
Abstract
The sensing performance of chemical sensors can be achieved not only by modification or hybridization of sensing materials but also through new design in device geometry. The performance of a chemical sensing device can be enhenced from a simple three‐dimensional (3D) chemiresistor‐based gas sensor platform with an increased surface area by forming networked, self‐assembled reduced graphene oxide (R‐GO) nanosheets on 3D SU8 micro‐pillar arrays. The 3D R‐GO sensor is highly responsive to low concentration of ammonia (NH 3) and nitrogen dioxide (NO 2) diluted in dry air at room temperature. Compared to the two‐dimensional planar R‐GO sensor structure, as the result of the increase in sensing area and interaction cross‐section of R‐GO on the same device area, the 3D R‐GO gas sensors show improved sensing performance with faster response (about 2%/s exposure), higher sensitivity, and even a possibly lower limit of detection towards NH 3 at room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The chemistry of graphene oxide
Dreyer, D. R., Park, S., Bielawski, C. W., & Ruoff, R. S. (2010) · Chem. Soc. Rev. · doi:10.1039/b917103g · Cited by 11,653
Sensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Cited by
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Self-citationEnzyme‐Based Glucose Sensor: From Invasive to Wearable Device
Lee, H., Hong, Y. J., Baik, S., Hyeon, T., & Kim, D. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701150 · Cited by 778
Self-citationReview—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Two-dimensional nanomaterial-based field-effect transistors for chemical and biological sensing
Mao, S., Chang, J., Pu, H., Lu, G., He, Q., Zhang, H., & Chen, J. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00827e · Cited by 404
Metadata
- Authors
- Duy, L. T., Kim, D., Trung, T. Q., Dang, V. Q., Kim, B., Moon, H. K., & Lee, N.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2014-12-05
- Volume
- 25
- Issue
- 6
- Pages
- 883-890
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2151774736
- Cited by
- 192
- References
- 2
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High Performance Three‐Dimensional Chemical Sensor Platform Using Reduced Graphene Oxide Formed on High Aspect‐Ratio Micro‐Pillars. https://app.cochat.ai/papers/10.1002/adfm.201401992
- The paper
- Duy, L. T., Kim, D., Trung, T. Q., Dang, V. Q., Kim, B., Moon, H. K., & Lee, N. (2015). High Performance Three‐Dimensional Chemical Sensor Platform Using Reduced Graphene Oxide Formed on High Aspect‐Ratio Micro‐Pillars. Advanced Functional Materials. https://doi.org/10.1002/adfm.201401992
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.