The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Porous Organic Field‐Effect Transistors for Enhanced Chemical Sensing Performances
Abstract
The thin‐film structures of chemical sensors based on conventional organic field‐effect transistors (OFETs) can limit the sensitivity of the devices toward chemical vapors, because charge carriers in OFETs are usually concentrated within a few molecular layers at the bottom of the organic semiconductor (OSC) film near the dielectric/semiconductor interface. Chemical vapor molecules have to diffuse through the OSC films before they can interact with charge carriers in the OFET conduction channel. It has been demonstrated that OFET ammonia sensors with porous OSC films can be fabricated by a simple vacuum freeze‐drying template method. The resulted devices can have ammonia sensitivity not only much higher than the pristine OFETs with thin‐film structure but also better than any previously reported OFET sensors, to the best of our knowledge. The porous OFETs show a relative sensitivity as high as 340% ppm−1 upon exposure to 10 parts per billion (ppb) NH 3. In addition, the devices also exhibit decent selectivity and stability. This general and simple strategy can be applied to a wide range of OFET chemical sensors to improve the device sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Xu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304
Cited by
Chemical and Biomolecule Sensing with Organic Field-Effect Transistors
Li, H., Shi, W., Song, J., Jang, H.-J., Dailey, J., Yu, J., & Katz, H. E. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00016 · Cited by 424
Functional gas sensing nanomaterials: A panoramic view
Malik, R., Tomer, V. K., Mishra, Y. K., & Lin, L. (2020) · Applied Physics Reviews · doi:10.1063/1.5123479 · Cited by 410
Yang, Y., Liu, Z., Zhang, G., Zhang, X., & Zhang, D. (2019) · Advanced Materials · doi:10.1002/adma.201903104 · Cited by 253
Metadata
- Authors
- Lu, J., Liu, D., Zhou, J., Chu, Y., Chen, Y., Wu, X., & Huang, J.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-03-21
- Volume
- 27
- Issue
- 20
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2599963552
- Cited by
- 159
- References
- 2
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Porous Organic Field‐Effect Transistors for Enhanced Chemical Sensing Performances. https://app.cochat.ai/papers/10.1002/adfm.201700018
- The paper
- Lu, J., Liu, D., Zhou, J., Chu, Y., Chen, Y., Wu, X., & Huang, J. (2017). Porous Organic Field‐Effect Transistors for Enhanced Chemical Sensing Performances. Advanced Functional Materials. https://doi.org/10.1002/adfm.201700018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.