Tissue-engineered peripheral nerve interfaces
Open accessAbstract
Research on neural interfaces has historically concentrated on development of systems for the brain; however, there is increasing interest in peripheral nerve interfaces (PNIs) that could provide benefit when peripheral nerve function is compromised, such as for amputees. Efforts focus on designing scalable and high-performance sensory and motor peripheral nervous system interfaces. Current PNIs face several design challenges such as undersampling of signals from the thousands of axons, nerve-fiber selectivity, and device-tissue integration. To improve PNIs, several researchers have turned to tissue engineering. Peripheral nerve tissue engineering has focused on designing regeneration scaffolds that mimic normal nerve extracellular matrix composition, provide advanced microarchitecture to stimulate cell migration, and have mechanical properties like the native nerve. By combining PNIs with tissue engineering, the goal is to promote natural axon regeneration into the devices to facilitate close contact with electrodes; in contrast, traditional PNIs rely on insertion or placement of electrodes into or around existing nerves, or do not utilize materials to actively facilitate axon regeneration. This review presents the state-of-the-art of PNIs and nerve tissue engineering, highlights recent approaches to combine neural-interface technology and tissue engineering, and addresses the remaining challenges with foreign-body response.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The peripheral nervous system develops the typical severity of FBR.
“Additionally, while the CNS is considered an immune privileged site (Louveau et al., 2015) where inflammation and fibrosis are more subdued than elsewhere in the body, the peripheral nervous system develops the typical severity of FBR (Spearman et al., 2018).”
From Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics (2021) · cites this paper as Spearman et al., 2018
The 'Limited Long-Term Reliability with Current Devices' section reports foreign-body responses around peripheral nerve interfaces, including encapsulation, scarring, inflammation, and one severe response. It also describes mild responses, so it does not establish that the peripheral nervous system generally develops a particular 'typical severity' of FBR. Page numbers were not provided in our copy. (LLM, conf=0.83)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 179 · Cited by 96
Research works printed but not linked: 33
- [1]Shealy CN, Mortimer JT, Reswick JB, Anesth. Analg. 1967, 46, 489. 4952225
- [9]Tracey KJ, Sci. Am. 2015, 312, 28.
- [13]McLoughlin MP, presented at MORS Personnel and National Security Workshop, DARPA Revolutionizing Prosthetics 2009, Laurel, MD 2009.
- [17]Delgado-Martínez I, Badia J, Pascual-Font A, Rodríguez-Baeza A, Navarro X, Front. Neurosci. 2016, 10, 286. 27445660 PMC4929846
- [24]Rodríguez FJ, Ceballos D, Schüttler M, Valero A, Valderrama E, Stieglitz T, Navarro X, Neurosci J. Methods 2000, 98, 105. 10880824
- [29]Hassler C, Boretius T, Stieglitz T, J. Polym. Sci. Part B Polym. Phys. 2011, 49, 18.
- [31]Jeong J, Jung W, Kim O, Chu JU, Youn I, Kim K, Oh SR, Park JW, Kim J, in Proc. IEEE RAS EMBS Int. Conf. Biomed. Robot. Biomechatronics, IEEE, Singapore 2016, 1148.
- [33]Kim Y, Romero-Ortega MI, MRS Bull. 2012, 37, 573.
- [46]Lacour SP, Courtine G, Guck J, Deisseroth K, Delp SL, Nat. Rev. Mater. 2016, 1, 16063.
- [49]Yoshida K, Pellinen D, Piven D, Rousche PJ, Kipke DR, in Proc. 5th Annu. Conf. IFESS, Sheffield, UK 2000, pp. 1497– 1500.
- [51]Boretius T, Yoshida K, Badia J, Harreby K, Kundu A, Navarro X, Jensen W, Stieglitz T, 2012 4th IEEE RAS EMBS Int. Conf. Biomed. Robot. Biomechatronics 2012, 282.
- [69]Akin T, Najafi K, Smoke RH, Bradley RM, IEEE Trans. Biomed. Eng. 1994, 41, 305. 8063296
- [70]Najafi K, IEEE Eng. Med. Biol. Mag. 1994, 13, 375.
- [74]Stieglitz T, Beutel H, Meyer J-U, Sensors Actuators A Phys. 1997, 60, 240.
- [81]Marks A, Anat. Rec. 1969, 163, 226.
- [87]Srinivasan A, Guo L, Bellamkonda RV, 2011 5th Int. IEEE/EMBS Conf. Neural Eng. (NER), IEEE, Cancun, Mexico 2011, 253.
- [97]Arslantunali D, Dursun T, Yucel D, Hasirci N, Hasirci V, Med. Devices Evid. Res. 2014, 7, 405. PMC4257109 25489251
- [100]Tonda-Turo C, Audisio C, Gnavi S, Chiono V, Gentile P, Raimondo S, Geuna S, Perroteau I, Ciardelli G, Adv. Eng. Mater. 2011, 13, 151.
- [106]Gonzalez-Perez F, Udina E, Navarro X, in Int. Rev. Neurobiology, Vol. 108, Academic Press, Cambridge, MA 2013, pp. 257– 275. 24083438
- [113]Thomas RC, Chung PE, Modi SP, Hardy JG, Schmidt CE, Eur. Polym. J. 2017, 87, 487.
- [114]Ribeiro-Resende VT, Koenig B, Nichterwitz S, Oberhoffner S, Schlosshauer B, Biomaterials 2009, 30, 5251. 19632717
- [140]Desai V, Shafor C, Spearman B, Wachs R, Graham J, Atkinson E, Nunamaker E, Schmidt C, Otto KJ, Judy J, 2016 38th Annu. Int. Conf. IEEE Eng. Med. Biol. Soc., IEEE, Orlando, FL 2016.
- [145]Urbanchek MG, Wei B, Baghmanli Z, Sugg K, Cederna PS, Plast. Reconstr. Surg. 2011, 128, 88. PMC4206183 23897336
- [149]Clements IP, Kim YT, Andreasen D, Bellamkonda RV, Proc. 3rd Int. IEEE EMBS Conf. Neural Eng., IEEE, Kohala Coast, HI 2007, 390.
- [151]Desai VH,, Spearman BS, Shafor CS, Natt S, Teem B, Graham JB, Atkinson EW, Wachs RA, Nunamaker EA, Otto KJ, Schmidt CE, Judy JW, 8th Int. IEEE/EMBS Conf. Neural Eng., IEEE, Shanghai, China 2017.
- [152]Nunamaker EA, Spearman BS, Graham JB, Atkinson EW, Desai VH, Shafor CS, Natt S, Wachs RA, Schmidt CE, Judy JW, Otto KJ, 8th Int. IEEE/EMBS Conf. Neural Eng., IEEE, Shanghai, China 2017.
- [153]Graham JB, Atkinson EW, Nunamaker EA, Spearman BS, Desai VH, Shafor CS, Natt S, Wachs RA, Schmidt CE, Judy JW, Otto KJ, 8th Int. IEEE/EMBS Conf. Neural Eng., IEEE, Shanghai, China 2017.
- [162]Grill WM, Nicolelis MAL, Simon SA, in Indwelling Neural Implants: Strategies for Contending with the In vivo Enviornment (Ed: Reichert WM), CRC Press, Boca Raton, FL 2008, pp. 41– 62. 21204399
- [178]Abidian MR, Martin DC, Adv. Funct. Mater. 2009, 19, 573.
- [184]McDermott MD, Olczak KP, Otto KJ, in Conf. Proc. IEEE Eng. Med. Biol. Soc., IEEE, Jeju Island, Korea 2017.
- [186]McDermott MD, Zhang J, Otto KJ, in Proc. 7th Int. IEEE/EMBS Conf. Neural Eng., IEEE, Montpellier, France 2015, 4526, 22.
- [188]Jedlicka SS, McKenzie JL, Leavesley SJ, Little KM, Webster TJ, Robinson JP, Nivens DE, Rickus JL, J. Mater. Chem. 2006, 16, 3221.
- [189]Jedlicka SS, Little KM, Nivens DE, Zemlyanov D, Rickus JL, J. Mater. Chem. 2007, 17, 5058.
- Authors
- Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E.
- Affiliations
- University of Florida (US)
- Purdue University West Lafayette (US)
- University of Florida Health (US)
- Corresponding author
- Otto, Kevin J.
- Judy, Jack W.
- Schmidt, Christine E.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2017-08-18
- Volume
- 28
- Issue
- 12
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- PMC
- PMC10569514
- OpenAlex
- W2745427487
- Cited by
- 96
- References
- 179
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 16 · 2023: 8 · 2022: 12 · 2021: 8 · 2020: 16 · 2019: 14 · 2018: 9
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Advanced Functional Materials (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Defense Advanced Research Projects Agency (HR0011‐15‐2‐0030)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
- Keywords
- peripheral nerve interfaces, neural interfaces, nerve regeneration scaffolds, axon regeneration, extracellular matrix, foreign body reaction, amputees
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review