Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 371

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

3D Printed Enzymatically Biodegradable Soft Helical Microswimmers

Open access
Wang, Xiaopu, Qin, Xiao‐Hua, Hu, Chengzhi, Terzopoulou, Anastasia, Chen, Xiang‐Zhong, Huang, Tian‐Yun, Maniura‐Weber, Katharina, Pané, Salvador, Nelson, Bradley J.·2018·Advanced Functional Materials

Abstract

Mobile micro‐ and nanorobots are proposed for future biomedical applications, such as diagnostics and targeted delivery. For their translation to clinical practice, biocompatibility and biodegradability of micro‐ and nanorobots are required aspects. The fabrication of small‐scale robots with non‐cytotoxic biodegradable soft components will allow for enhanced device assimilation, optimal tissue interaction and minimized immune reactions. The 3D microfabrication of biodegradable soft helical microswimmers via two‐photon polymerization of the non‐toxic photocrosslinkable hydrogel gelatin methacryloyl (GelMA) is reported. GelMA microswimmers are fabricated with user‐defined geometry and rendered magnetically responsive by decorating their surface with magnetic nanoparticles. In contrast to previous rigid helical microrobots, the soft helical microswimmers can corkscrew above the step‐out frequency with relatively high values of forward velocity, suggesting an unprecedented self‐adaptive behavior. Cytotoxicity assays show the toxicity of GelMA is at least three orders of magnitude lower than that of poly(ethyleneglycol) diacrylates, which are widely used for fabricating hydrogel‐based microswimmers. GelMA microswimmers are fully degradable by collagenases. Furthermore, they support cell attachment and growth, and are gradually digested by cell‐released enzymes during culture. These non‐cytotoxic biodegradable hydrogel microswimmers will greatly expand their applications in medicine by eliminating the concerns of retrieving microrobots after fulfilling tasks in body.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adfm.201804107

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 371

Metadata

Authors
Wang, X., Qin, X., Hu, C., Terzopoulou, A., Chen, X., Huang, T., Maniura‐Weber, K., Pané, S., & Nelson, B. J.
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2018-09-19
Volume
28
Issue
45
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2891092840
Cited by
371
References
2
FWCI
18.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D Printed Enzymatically Biodegradable Soft Helical Microswimmers. https://app.cochat.ai/papers/10.1002/adfm.201804107
The paper
Wang, X., Qin, X., Hu, C., Terzopoulou, A., Chen, X., Huang, T., Maniura‐Weber, K., Pané, S., & Nelson, B. J. (2018). 3D Printed Enzymatically Biodegradable Soft Helical Microswimmers. Advanced Functional Materials. https://doi.org/10.1002/adfm.201804107

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.