The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Stretchable and Temperature‐Sensitive Polymer Optical Fibers for Wearable Health Monitoring
Abstract
Stretchable physical sensors that can detect and quantify human physiological signals such as temperature, are essential to the realization of healthcare devices for biomedical monitoring and human–machine interfaces. Despite recent achievements in stretchable electronic sensors using various conductive materials and structures, the design of stretchable sensors in optics remains a considerable challenge. Here, an optical strategy for the design of stretchable temperature sensors, which can maintain stable performance even under a strain deformation up to 80%, is reported. The optical temperature sensor is fabricated by the incorporation of thermal‐sensitive upconversion nanoparticles (UCNPs) in stretchable polymer‐based optical fibers (SPOFs). The SPOFs are made from stretchable elastomers and constructed in a step‐index core/cladding structure for effective light confinements. The UCNPs, incorporated in the SPOFs, provide thermal‐sensitive upconversion emissions at dual wavelengths for ratiometric temperature sensing by near‐infrared excitation, while the SPOFs endow the sensor with skin‐like mechanical compliance and excellent light‐guiding characteristics for laser delivery and emission collection. The broad applications of the proposed sensor in real‐time monitoring of the temperature and thermal activities of the human body, providing optical alternatives for wearable health monitoring, are demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Highly flexible and stretchable optical strain sensing for human motion detection
Guo, J., Niu, M., & Yang, C. (2017) · Optica · doi:10.1364/optica.4.001285 · Cited by 220
Self-citation
Cited by
Rare-Earth Doping in Nanostructured Inorganic Materials
Zheng, B., Fan, J., Chen, B., Qin, X., Wang, J., Wang, F., Deng, R., & Liu, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00644 · Cited by 1,204
Wearable Pressure Sensors for Pulse Wave Monitoring
Meng, K., Xiao, X., Wei, W., Chen, G., Nashalian, A., Shen, S., Xiao, X., & Chen, J. (2022) · Advanced Materials · doi:10.1002/adma.202109357 · Cited by 878
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Functional Fibers and Fabrics for Soft Robotics, Wearables, and Human–Robot Interface
Xiong, J., Chen, J., & Lee, P. S. (2021) · Advanced Materials · doi:10.1002/adma.202002640 · Cited by 627
Metadata
- Authors
- Guo, J., Zhou, B., Yang, C., Dai, Q., & Kong, L.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2019-06-17
- Volume
- 29
- Issue
- 33
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W2952833947
- Cited by
- 241
- References
- 3
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.