Cited by 169Gas Sensing Nanomaterials and SensorsElectrical and Thermal Properties of MaterialsFerroelectric and Piezoelectric Materials

Perovskite‐Induced Ultrasensitive and Highly Stable Humidity Sensor Systems Prepared by Aerosol Deposition at Room Temperature

Cho, Myung‐Yeon, Kim, Sunghoon, Kim, Ik‐Soo, Kim, Eun‐Seong, Wang, Zhi‐Ji, Kim, Nam‐Young, Kim, Sang‐Wook, Oh, Jong‐Min·2020·Advanced Functional Materials

Abstract

A new capacitive‐type humidity sensor is proposed using novel materials and fabrication process for practical applications in sensitive environments and cost‐effective functional devices that require ultrasensing performances. Metal halide perovskites (CsPbBr 3 and CsPb 2 Br 5 ) combined with diverse ceramics (Al 2 O 3 , TiO 2 , and BaTiO 3 ) are selected as sensing materials for the first time, and nanocomposite powders are deposited by aerosol deposition (AD) process. A state‐of‐the‐art CsPb 2 Br 5 /BaTiO 3 nanocomposite humidity sensor prepared by AD process exhibits a significant increase in humidity sensing compared with CsPbBr 3 /Al 2 O 3 and CsPbBr 3 /TiO 2 sensors. An outstanding humidity sensitivity (21426 pF RH% −1 ) with superior linearity (0.991), fast response/recovery time (5 s), low hysteresis of 1.7%, and excellent stability in a wide range of relative humidity is obtained owing to a highly porous structure, effective charge separation, and water‐resistant characteristics of CsPb 2 Br 5 . Notably, this unprecedented result is obtained via a simple one‐step AD process within a few minutes at room temperature without any auxiliary treatment. The synergetic combination of AD technique and perovskite‐based nanocomposite can be potentially applied toward the development of multifunctional sensing devices.

Integrity signals

Registry

Crossref · 10.1002/adfm.201907449

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Capacitive humidity sensors utilize the principle that the capacitance value of perovskite materials changes with variations in humidity.

    “Capacitive humidity sensors utilize the principle that the capacitance value of perovskite materials changes with variations in humidity [94].”
  • Perovskite-based humidity sensors include resistive, capacitive, and frequency-type humidity sensors.

    “Perovskite-based humidity sensors include resistive, capacitive, and frequency-type humidity sensors (Figure 4) [28,92,94,95].”
  • As environmental humidity rises, water molecules adsorb onto the perovskite surface, forming a layer that increases the sensor's capacitance; the capacitance change directly reflects humidity variations.

    “As environmental humidity rises, water molecules adsorb onto the perovskite surface, forming a layer that increases the sensor's capacitance.The capacitance change directly reflects humidity variations (Figure 4D) [94].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Cho, M., Kim, S., Kim, I., Kim, E., Wang, Z., Kim, N., Kim, S., & Oh, J.
Affiliations
  • Kwangwoon University (KR)
  • Nanomaterials Laboratory Department of Molecular Science and Technology Ajou University Suwon 16499 Republic of Korea
  • Ajou University (KR)
Corresponding author
  • Kim, Nam‐Young
  • Kim, Sang‐Wook
  • Oh, Jong‐Min
Venue
Advanced Functional Materials
Publisher
Wiley
Published
2019-11-20
Volume
30
Issue
3
ISSN
  • 1616-301X (ISSN-L)
  • 1616-3028
OpenAlex
W2989723766
Cited by
169
References
1
Citations by year
2026: 12 · 2025: 25 · 2024: 30 · 2023: 25 · 2022: 35 · 2021: 32 · 2020: 10
FWCI
6.92
Type
journal article
Language
en
Open access
closed
Locations
Advanced Functional Materials (publishedVersion)
Funders
  • National Research Foundation of Korea
  • Ministry of Science, ICT and Future Planning (2017R1C1B5017013, 2014R1A5A1009799, 2009‐0082580)
  • Ministry of Education (2018R1A6A1A03025242)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Thermal Properties of Materials
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
Keywords
humidity sensor, halide perovskites, CsPbBr3, CsPb2Br5, aerosol deposition, capacitive humidity sensing, nanocomposites, barium titanate, alumina, titanium dioxide, room-temperature fabrication, porous structure, water resistance, charge separation, sensor stability

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review