The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Biocompatible Poly(lactic acid)‐Based Hybrid Piezoelectric and Electret Nanogenerator for Electronic Skin Applications
Abstract
Human machine interface (HMI) devices, which can convert human motions to electrical signals to control/charge electronic devices, have attracted tremendous attention from the engineering and science fields. Herein, the high output voltage from a nonpiezoelectric meso‐poly(lactic acid) (meso‐PLA) electret‐based triboelectric nanogenerator (NG) is combined with the relatively high current from a double‐layered poly(l‐lactic acid) (PLLA)‐based piezoelectric nanogenerator (PENG) for an E‐skin (electronic skin) (HMI) device application. The hybrid NG with a cantilever structure can generate an output voltage of 70 V and a current of 25 µA at the resonance frequency of 19.7 Hz and a tip load of 4.71 g. Moreover, the output power of the hybrid NG reaches 0.31 mW, which is 11% higher than that from the PLLA‐based PENG. Furthermore, it is demonstrated that the PLA‐based hybrid NG can be used to turn a light‐emitting diode light on and off through an energy management circuit during a bending test. Finally, it is demonstrated that the PLA‐based woven E‐skin device can generate the output signals of 35 V (Voc) and 1 µA (Isc) during an elbow bending test. The advantages of biocompatible, ease of fabrication, and relatively high output power in the hybrid NG device show great promise for future E‐skin applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, S., Xie, Y., Niu, S., Lin, L., Liu, C., Zhou, Y. S., & Wang, Z. L. (2014) · Advanced Materials · doi:10.1002/adma.201402491 · Cited by 679
Self-citationHa, M., Lim, S., Park, J., Um, D., Lee, Y., & Ko, H. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500453 · Cited by 395
Xu, B., Akhtar, A., Liu, Y., Chen, H., Yeo, W., Park, S. I., Boyce, B., Kim, H., Yu, J., Lai, H., et al. (2016) · Advanced Materials · doi:10.1002/adma.201504155 · Cited by 304
Properties of crosslinked polylactides (PLLA & PDLA) by radiation and its biodegradability
Quynh, T. M., Mitomo, H., Nagasawa, N., Wada, Y., Yoshii, F., & Tamada, M. (2007) · European Polymer Journal · doi:10.1016/j.eurpolymj.2007.03.007 · Cited by 140
Cited by
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Zhou, H., Zhang, Y., Qiu, Y., Wu, H., Qin, W., Liao, Y., Yu, Q., & Cheng, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112569 · Cited by 370
Zarei, M., Lee, G., Lee, S. G., & Cho, K. (2023) · Advanced Materials · doi:10.1002/adma.202203193 · Cited by 345
A review on PLA-based biodegradable materials for biomedical applications
Hussain, M., Khan, S. M., Shafiq, M., & Abbas, N. (2024) · Giant · doi:10.1016/j.giant.2024.100261 · Cited by 326
Zhu, M., Yi, Z., Yang, B., & Lee, C. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101016 · Cited by 295
Metadata
- Authors
- Gong, S., Zhang, B., Zhang, J., Wang, Z. L., & Ren, K.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-02-18
- Volume
- 30
- Issue
- 14
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3007691328
- Cited by
- 162
- References
- 4
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.