The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Unveiling the Structural Descriptor of A3B2X9 Perovskite Derivatives toward X‐Ray Detectors with Low Detection Limit and High Stability
Abstract
Metal halide perovskites and derivatives exhibit a high sensitivity and low detection limit as direct X‐ray detectors. Inorganic 2D bismuth halide perovskites are promising for X‐ray detections, but have not been reported. Moreover, the quantitative relationship between the structural dimensionality of A 3 B 2 X 9 perovskites and their compositions has never been investigated, and the underlying mechanism is unclear. Here, the key structural descriptors for 2D A 3 B 2 X 9 perovskite derivatives are reported: i) octahedral factor μ, 0.377 < μ < 0895; ii) tolerance factor t, 0.8 < t < 1.06; iii) (r A‐0.55)/t < 1.48 Å. Accordingly, a new 2D A 3 B 2 X 9 perovskite derivative, Rb 3 Bi 2 I 9, with high X‐ray attenuation coefficients is found. The assembled X‐ray detector exhibits a high μτ product of 2.51 × 10−3 cm 2 V−1, good sensitivity for 159.7 μC Gy air−1 cm−2, and a record low detection limit of 8.32 nGy air s−1 among all direct and indirect perovskite X‐ray detectors. The device also exhibits good stability toward external bias and continuous gamma ray radiations (480 000 Gy). This work provides crystal structural insights to rationally design 2D perovskites for new types of radiation detectors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized Gradient Approximation Made Simple
Perdew, J. P., Burke, K., & Ernzerhof, M. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3865 · Cited by 215,824
Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set
Kresse, G., & Furthmüller, J. (1996) · Physical Review B · doi:10.1103/physrevb.54.11169 · Cited by 123,652
Projector augmented-wave method
Blöchl, P. E. (1994) · Physical Review B · doi:10.1103/physrevb.50.17953 · Cited by 92,732
From ultrasoft pseudopotentials to the projector augmented-wave method
Kresse, G., & Joubert, D. (1999) · Physical Review B · doi:10.1103/physrevb.59.1758 · Cited by 85,307
Kresse, G., & Furthmüller, J. (1996) · Computational Materials Science · doi:10.1016/0927-0256(96)00008-0 · Cited by 75,638
Organic–Inorganic Perovskites: Structural Versatility for Functional Materials Design
Saparov, B., & Mitzi, D. B. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00715 · Cited by 2,907
All-inorganic perovskite nanocrystal scintillators
Chen, Q., Wu, J., Ou, X., Huang, B., Almutlaq, J., Zhumekenov, A. A., Guan, X., Han, S., Liang, L., Yi, Z., et al. (2018) · Nature · doi:10.1038/s41586-018-0451-1 · Cited by 2,052
Sensitive X-ray detectors made of methylammonium lead tribromide perovskite single crystals
Wei, H., Fang, Y., Mulligan, P., Chuirazzi, W., Fang, H.-H., Wang, C., Ecker, B. R., Gao, Y., Loi, M. A., Cao, L., et al. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.41 · Cited by 1,877
Cs2AgBiBr6 single-crystal X-ray detectors with a low detection limit
Pan, W., Wu, H., Luo, J., Deng, Z., Ge, C., Chen, C., Jiang, X., Yin, W.-J., Niu, G., Zhu, L., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0012-4 · Cited by 1,416
Self-citationWei, W., Zhang, Y., Xu, Q., Wei, H., Fang, Y., Wang, Q., Deng, Y., Li, T., Gruverman, A., Cao, L., et al. (2017) · Nature Photonics · doi:10.1038/nphoton.2017.43 · Cited by 814
Cited by
Metal Halide Perovskites for X-ray Imaging Scintillators and Detectors
Zhou, Y., Chen, J., Bakr, O. M., & Mohammed, O. F. (2021) · ACS Energy Letters · doi:10.1021/acsenergylett.0c02430 · Cited by 891
Metal Halide Perovskites for X-Ray Detection and Imaging
Wu, H., Ge, Y., Niu, G., & Tang, J. (2021) · Matter · doi:10.1016/j.matt.2020.11.015 · Cited by 585
Self-citationHalide perovskites for high-performance X-ray detector
Li, Z., Zhou, F., Yao, H., Ci, Z., Yang, Z., & Jin, Z. (2021) · Materials Today · doi:10.1016/j.mattod.2021.01.028 · Cited by 370
Self-citationPerovskite: Scintillators, direct detectors, and X-ray imagers
Jana, A., Cho, S., Patil, S. A., Meena, A., Jo, Y., Sree, V. G., Park, Y., Kim, H., Im, H., & Taylor, R. A. (2022) · Materials Today · doi:10.1016/j.mattod.2022.04.009 · Cited by 363
Triple‐Cation and Mixed‐Halide Perovskite Single Crystal for High‐Performance X‐ray Imaging
Liu, Y., Zhang, Y., Zhu, X., Feng, J., Spanopoulos, I., Ke, W., He, Y., Ren, X., Yang, Z., Xiao, F., et al. (2021) · Advanced Materials · doi:10.1002/adma.202006010 · Cited by 349
Metadata
- Authors
- Xia, M., Yuan, J., Niu, G., Du, X., Yin, L., Pan, W., Luo, J., Li, Z., Zhao, H., Xue, K., Miao, X., & Tang, J.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-05-04
- Volume
- 30
- Issue
- 24
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3020855884
- Cited by
- 272
- References
- 22
- FWCI
- 23.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Unveiling the Structural Descriptor of A3B2X9 Perovskite Derivatives toward X‐Ray Detectors with Low Detection Limit and High Stability. https://app.cochat.ai/papers/10.1002/adfm.201910648
- The paper
- Xia, M., Yuan, J., Niu, G., Du, X., Yin, L., Pan, W., Luo, J., Li, Z., Zhao, H., Xue, K., Miao, X., & Tang, J. (2020). Unveiling the Structural Descriptor of A3B2X9 Perovskite Derivatives toward X‐Ray Detectors with Low Detection Limit and High Stability. Advanced Functional Materials. https://doi.org/10.1002/adfm.201910648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.